Reproducibilidad de parámetros radiográficos para determinar el éxito quirúrgico de fracturas de radio distal.

Saved in:
Bibliographic Details
Title: Reproducibilidad de parámetros radiográficos para determinar el éxito quirúrgico de fracturas de radio distal.
Alternate Title: Reliability of radiographic parameters to determine the surgical success in distal radius fractures.
Authors: N., García-González1, E., Berúmen-Nafarrate1, L., Ávila-Carrasco2, M., Martínez-Fierro2, J., Monárrez-Espino1,2 joel.monarrez@christus.mx
Source: Acta Ortopédica Mexicana. Jul/Aug2022, Vol. 36 Issue 4, p216-222. 7p.
Abstract (English): Introduction: distal radius fractures are the most common in upper extremities. Therefore, it is important to standardize radiographic measures for their surgical approach. This study assessed the intra/interobserver reproducibility of radiographic parameters associated with surgical success of distal radius fractures. Material and methods: retrospective cross-sectional design of secondary data extracted from clinical records. Posteroanterior and lateral X-rays of 112 distal radius fractures were assessed by two trauma specialists standardized in the measurements required to compute five parameters indicative of postoperative success: radial height, radial inclination, volar tilt, ulnar variance, and articular stepoff. The reproducibility of distances and angles was evaluated using the Bland-Altman method, calculating the mean of the difference between measurements, the range at ± 2 SD, and the proportion of measurements outside ± 2 SD. Postoperative success was also compared between patients with and without obesity according to the mean of the two measures made by each evaluator. Results: evaluator 1 had the largest intra-observer difference in radial height (0.16 mm) and the largest proportion outside ± 2 SD in ulnar variance (8.1%); evaluator 2 had the largest difference in volar tilt (1.92o) and the highest proportion in radial inclination (10.7%). The largest inter-observer difference was for ulnar variance (1.02 mm) and the largest proportion outside ± 2 SD. for radial height (5.4%). Radial tilt had the largest difference (1.41o) with 4.5% of measurements outside ± 2 SD. Ulnar variance and volar tilt had the largest difference in postoperative success between evaluators, especially in patients with obesity. Conclusion: improving the radiographic quality and standardizing the measurements results in more reproducible indicators. [ABSTRACT FROM AUTHOR]
Abstract (Spanish): Introducción: las fracturas del radio distal son las más comunes en extremidades superiores. Estandarizar las mediciones radiográficas para su abordaje quirúrgico es importante. Este estudio midió la reproducibilidad intra/interobservador de parámetros radiográficos asociados al éxito quirúrgico en estas fracturas. Material y métodos: diseño transversal retrospectivo con datos secundarios de expedientes clínicos. Se evaluaron radiografías de 112 fracturas en planos posteroanterior y lateral por dos traumatólogos estandarizados en toma de mediciones para calcular cinco parámetros indicativos de éxito postquirúrgico: altura radial, inclinación radial, inclinación volar, varianza cubital y escalón articular. La reproducibilidad de distancias y ángulos se evaluó con el método de Bland-Altman calculando: diferencia media entre mediciones, rango a ± 2 DE y proporción de mediciones fuera de ± 2 DE. El éxito postquirúrgico se comparó en pacientes con/sin obesidad según la media de las dos mediciones de cada evaluador. Resultados: el evaluador 1 tuvo la mayor diferencia intraobservador en altura radial (0.16 mm) y la mayor proporción fuera de ± 2 DE en varianza cubital (8.1%); el evaluador 2 tuvo la mayor diferencia en inclinación volar (1.92o) y la mayor proporción en inclinación radial (10.7%). La mayor diferencia interobservador fue en varianza cubital (1.02 mm) y la mayor proporción fuera de ± 2 DE en altura radial (5.4%). La inclinación radial tuvo la mayor diferencia (1.41o) con 4.5% de mediciones fuera de ± 2 DE. La varianza cubital y la inclinación volar tuvieron la mayor diferencia de éxito postquirúrgico entre evaluadores, sobre todo en pacientes con obesidad. Conclusión: mejorar la calidad radiográfica y estandarizar las mediciones resulta en indicadores más reproducibles. [ABSTRACT FROM AUTHOR]
Copyright of Acta Ortopédica Mexicana is the property of Sociedad Mexicana de Ortopedia, AC and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: MedicLatina
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: lth
DbLabel: MedicLatina
An: 162229763
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Reproducibilidad de parámetros radiográficos para determinar el éxito quirúrgico de fracturas de radio distal.
– Name: TitleAlt
  Label: Alternate Title
  Group: TiAlt
  Data: Reliability of radiographic parameters to determine the surgical success in distal radius fractures.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22N%2E%2C+García-González%22">N., García-González</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22E%2E%2C+Berúmen-Nafarrate%22">E., Berúmen-Nafarrate</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22L%2E%2C+Ávila-Carrasco%22">L., Ávila-Carrasco</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22M%2E%2C+Martínez-Fierro%22">M., Martínez-Fierro</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22J%2E%2C+Monárrez-Espino%22">J., Monárrez-Espino</searchLink><relatesTo>1,2</relatesTo><i> joel.monarrez@christus.mx</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Acta+Ortopédica+Mexicana%22">Acta Ortopédica Mexicana</searchLink>. Jul/Aug2022, Vol. 36 Issue 4, p216-222. 7p.
– Name: Abstract
  Label: Abstract (English)
  Group: Ab
  Data: Introduction: distal radius fractures are the most common in upper extremities. Therefore, it is important to standardize radiographic measures for their surgical approach. This study assessed the intra/interobserver reproducibility of radiographic parameters associated with surgical success of distal radius fractures. Material and methods: retrospective cross-sectional design of secondary data extracted from clinical records. Posteroanterior and lateral X-rays of 112 distal radius fractures were assessed by two trauma specialists standardized in the measurements required to compute five parameters indicative of postoperative success: radial height, radial inclination, volar tilt, ulnar variance, and articular stepoff. The reproducibility of distances and angles was evaluated using the Bland-Altman method, calculating the mean of the difference between measurements, the range at ± 2 SD, and the proportion of measurements outside ± 2 SD. Postoperative success was also compared between patients with and without obesity according to the mean of the two measures made by each evaluator. Results: evaluator 1 had the largest intra-observer difference in radial height (0.16 mm) and the largest proportion outside ± 2 SD in ulnar variance (8.1%); evaluator 2 had the largest difference in volar tilt (1.92o) and the highest proportion in radial inclination (10.7%). The largest inter-observer difference was for ulnar variance (1.02 mm) and the largest proportion outside ± 2 SD. for radial height (5.4%). Radial tilt had the largest difference (1.41o) with 4.5% of measurements outside ± 2 SD. Ulnar variance and volar tilt had the largest difference in postoperative success between evaluators, especially in patients with obesity. Conclusion: improving the radiographic quality and standardizing the measurements results in more reproducible indicators. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label: Abstract (Spanish)
  Group: Ab
  Data: Introducción: las fracturas del radio distal son las más comunes en extremidades superiores. Estandarizar las mediciones radiográficas para su abordaje quirúrgico es importante. Este estudio midió la reproducibilidad intra/interobservador de parámetros radiográficos asociados al éxito quirúrgico en estas fracturas. Material y métodos: diseño transversal retrospectivo con datos secundarios de expedientes clínicos. Se evaluaron radiografías de 112 fracturas en planos posteroanterior y lateral por dos traumatólogos estandarizados en toma de mediciones para calcular cinco parámetros indicativos de éxito postquirúrgico: altura radial, inclinación radial, inclinación volar, varianza cubital y escalón articular. La reproducibilidad de distancias y ángulos se evaluó con el método de Bland-Altman calculando: diferencia media entre mediciones, rango a ± 2 DE y proporción de mediciones fuera de ± 2 DE. El éxito postquirúrgico se comparó en pacientes con/sin obesidad según la media de las dos mediciones de cada evaluador. Resultados: el evaluador 1 tuvo la mayor diferencia intraobservador en altura radial (0.16 mm) y la mayor proporción fuera de ± 2 DE en varianza cubital (8.1%); el evaluador 2 tuvo la mayor diferencia en inclinación volar (1.92o) y la mayor proporción en inclinación radial (10.7%). La mayor diferencia interobservador fue en varianza cubital (1.02 mm) y la mayor proporción fuera de ± 2 DE en altura radial (5.4%). La inclinación radial tuvo la mayor diferencia (1.41o) con 4.5% de mediciones fuera de ± 2 DE. La varianza cubital y la inclinación volar tuvieron la mayor diferencia de éxito postquirúrgico entre evaluadores, sobre todo en pacientes con obesidad. Conclusión: mejorar la calidad radiográfica y estandarizar las mediciones resulta en indicadores más reproducibles. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Acta Ortopédica Mexicana is the property of Sociedad Mexicana de Ortopedia, AC and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=162229763
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.35366/109806
    Languages:
      – Code: spa
        Text: Spanish
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 216
    Titles:
      – TitleFull: Reproducibilidad de parámetros radiográficos para determinar el éxito quirúrgico de fracturas de radio distal.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: N., García-González
      – PersonEntity:
          Name:
            NameFull: E., Berúmen-Nafarrate
      – PersonEntity:
          Name:
            NameFull: L., Ávila-Carrasco
      – PersonEntity:
          Name:
            NameFull: M., Martínez-Fierro
      – PersonEntity:
          Name:
            NameFull: J., Monárrez-Espino
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 07
              Text: Jul/Aug2022
              Type: published
              Y: 2022
          Identifiers:
            – Type: issn-print
              Value: 23064102
          Numbering:
            – Type: volume
              Value: 36
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: Acta Ortopédica Mexicana
              Type: main
ResultId 1