Prótesis bisagra rotatoria GMK. Una opción válida para la cirugía de revisión protésica compleja de rodilla.

Saved in:
Bibliographic Details
Title: Prótesis bisagra rotatoria GMK. Una opción válida para la cirugía de revisión protésica compleja de rodilla.
Alternate Title: GMK rotating hinge prosthesis. A valid option for complex revision knee prosthetic surgery.
Authors: Garrido-Ferrera, J. F.1 Garrido.jos1@gmail.com, Marquina-Moraleda, V.1, Marco-Díaz, L.1, Colomina-Rodríguez, R.1, Hernández-Ferrando, L.1
Source: Acta Ortopédica Mexicana. may/jun2024, Vol. 38 Issue 3, p149-154. 6p.
Abstract (English): Introduction: revision joint replacement surgery presents a surgical challenge. The use of rotating hinge prostheses is an option in patients with femorotibial bone defects, ligament insufficiency, or significant deformities. The aim of this study was to evaluate the clinical, functional, and radiological outcomes of a series of patients who underwent surgery using the GMK Hinge (Medacta®) rotational hinge model. Material and methods: a descriptive, retrospective, and analytical study was conducted on a series of 36 patients, with a mean age of 72.5 years (47-85), operated on by the same surgical team between January 2015 and January 2022. The etiology of revision was chronic infection in 38.9% of cases, instability in 33.3%, aseptic loosening in 19.4%, and stiffness in 8.4%. The Knee Society Score (KSS) and the Forgotten Joint Score (FJS) were used to assess functional outcomes. The degree of femorotibial bone defect was evaluated using the Anderson Orthopaedic Research Institute (AORI) classification. Postoperative complications are also recorded. Results: a total of 36 patients, 17 males and 19 females, were included, with a mean follow-up of 30 months (12-66). Twelve patients had type 1 defects, ten had 2A defects, ten had 2B defects, and two had type 3 defects on the femoral side, with the use of wedges required for asymmetrical defects (21 patients). The predominant tibial defect was type 1 without the need for wedges. The majority achieved a satisfactory outcome on the KSS scale (72.2 ± 9.4), with significant differences compared to the previous KSS (54.3 ± 8.9). A score of 31 (12-67) was also obtained on the FJS scale. Postoperative complications were present in 16.7% of patients. Conclusions: complex prosthetic revision surgery using a rotating hinge prosthesis represents a suitable therapeutic option, yielding appropriate clinical and functional outcomes, albeit not without complications. [ABSTRACT FROM AUTHOR]
Abstract (Spanish): Introducción: la cirugía de revisión protésica constituye un reto quirúrgico. La utilización de prótesis tipo bisagra rotatoria es una opción en pacientes con defectos óseos femorotibiales, insuficiencia ligamentosa o importantes deformidades. El objetivo del presente estudio es evaluar los resultados clínicos, funcionales y radiológicos de una serie de pacientes intervenidos mediante un modelo de bisagra rotacional GMK Hinge (Medacta®). Material y métodos: estudio descriptivo retrospectivo y analítico que incluyó una serie de 36 pacientes, con edad media de 72.5 años (47-85) intervenidos entre Enero de 2015 y Enero de 2022 por el mismo equipo quirúrgico. La etiología de revisión fue infección crónica en 38.9%, inestabilidad en 33.3%, aflojamiento aséptico en 19.4% y rigidez en 8.4%. Para la evaluación de resultados funcionales se utiliza la escala Knee Society Score (KSS), así como la escala Forgotten Joint Score (FJS). El grado de defecto óseo femorotibial se evaluó mediante la clasificación de Anderson Orthopaedic Research Institute (AORI). También se registraron las complicaciones postquirúrgicas. Resultados: se analizó un total de 36 pacientes, 17 varones y 19 mujeres, con seguimiento medio de 30 meses (12-66). Se encontraron doce pacientes con defectos tipo 1, diez con defectos 2A, diez con defectos 2B y dos con defecto tipo 3 en la vertiente femoral, siendo necesario la utilización de cuñas en defectos asimétricos (21 pacientes). El defecto tibial mayoritario fue el tipo 1 sin necesidad de cuñas. La mayoría obtuvo un resultado satisfactorio en la escala KSS (72.2 ± 9.4), con diferencias significativas respecto al KSS previo (54.3 ± 8.9). Se obtuvo también una puntuación de 31 (12-67) en la escala FJS. Presentaron complicaciones postoperatorias 16.7% de los pacientes. Conclusiones: la cirugía de revisión protésica compleja mediante prótesis tipo bisagra rotacional constituye una correcta opción terapéutica, presentando resultados clínicos y funcionales adecuados, no exentos de complicaciones. [ABSTRACT FROM AUTHOR]
Copyright of Acta Ortopédica Mexicana is the property of Sociedad Mexicana de Ortopedia, AC and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: MedicLatina
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: lth
DbLabel: MedicLatina
An: 177542575
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Prótesis bisagra rotatoria GMK. Una opción válida para la cirugía de revisión protésica compleja de rodilla.
– Name: TitleAlt
  Label: Alternate Title
  Group: TiAlt
  Data: GMK rotating hinge prosthesis. A valid option for complex revision knee prosthetic surgery.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Garrido-Ferrera%2C+J%2E+F%2E%22">Garrido-Ferrera, J. F.</searchLink><relatesTo>1</relatesTo><i> Garrido.jos1@gmail.com</i><br /><searchLink fieldCode="AR" term="%22Marquina-Moraleda%2C+V%2E%22">Marquina-Moraleda, V.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Marco-Díaz%2C+L%2E%22">Marco-Díaz, L.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Colomina-Rodríguez%2C+R%2E%22">Colomina-Rodríguez, R.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Hernández-Ferrando%2C+L%2E%22">Hernández-Ferrando, L.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Acta+Ortopédica+Mexicana%22">Acta Ortopédica Mexicana</searchLink>. may/jun2024, Vol. 38 Issue 3, p149-154. 6p.
– Name: Abstract
  Label: Abstract (English)
  Group: Ab
  Data: Introduction: revision joint replacement surgery presents a surgical challenge. The use of rotating hinge prostheses is an option in patients with femorotibial bone defects, ligament insufficiency, or significant deformities. The aim of this study was to evaluate the clinical, functional, and radiological outcomes of a series of patients who underwent surgery using the GMK Hinge (Medacta®) rotational hinge model. Material and methods: a descriptive, retrospective, and analytical study was conducted on a series of 36 patients, with a mean age of 72.5 years (47-85), operated on by the same surgical team between January 2015 and January 2022. The etiology of revision was chronic infection in 38.9% of cases, instability in 33.3%, aseptic loosening in 19.4%, and stiffness in 8.4%. The Knee Society Score (KSS) and the Forgotten Joint Score (FJS) were used to assess functional outcomes. The degree of femorotibial bone defect was evaluated using the Anderson Orthopaedic Research Institute (AORI) classification. Postoperative complications are also recorded. Results: a total of 36 patients, 17 males and 19 females, were included, with a mean follow-up of 30 months (12-66). Twelve patients had type 1 defects, ten had 2A defects, ten had 2B defects, and two had type 3 defects on the femoral side, with the use of wedges required for asymmetrical defects (21 patients). The predominant tibial defect was type 1 without the need for wedges. The majority achieved a satisfactory outcome on the KSS scale (72.2 ± 9.4), with significant differences compared to the previous KSS (54.3 ± 8.9). A score of 31 (12-67) was also obtained on the FJS scale. Postoperative complications were present in 16.7% of patients. Conclusions: complex prosthetic revision surgery using a rotating hinge prosthesis represents a suitable therapeutic option, yielding appropriate clinical and functional outcomes, albeit not without complications. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label: Abstract (Spanish)
  Group: Ab
  Data: Introducción: la cirugía de revisión protésica constituye un reto quirúrgico. La utilización de prótesis tipo bisagra rotatoria es una opción en pacientes con defectos óseos femorotibiales, insuficiencia ligamentosa o importantes deformidades. El objetivo del presente estudio es evaluar los resultados clínicos, funcionales y radiológicos de una serie de pacientes intervenidos mediante un modelo de bisagra rotacional GMK Hinge (Medacta®). Material y métodos: estudio descriptivo retrospectivo y analítico que incluyó una serie de 36 pacientes, con edad media de 72.5 años (47-85) intervenidos entre Enero de 2015 y Enero de 2022 por el mismo equipo quirúrgico. La etiología de revisión fue infección crónica en 38.9%, inestabilidad en 33.3%, aflojamiento aséptico en 19.4% y rigidez en 8.4%. Para la evaluación de resultados funcionales se utiliza la escala Knee Society Score (KSS), así como la escala Forgotten Joint Score (FJS). El grado de defecto óseo femorotibial se evaluó mediante la clasificación de Anderson Orthopaedic Research Institute (AORI). También se registraron las complicaciones postquirúrgicas. Resultados: se analizó un total de 36 pacientes, 17 varones y 19 mujeres, con seguimiento medio de 30 meses (12-66). Se encontraron doce pacientes con defectos tipo 1, diez con defectos 2A, diez con defectos 2B y dos con defecto tipo 3 en la vertiente femoral, siendo necesario la utilización de cuñas en defectos asimétricos (21 pacientes). El defecto tibial mayoritario fue el tipo 1 sin necesidad de cuñas. La mayoría obtuvo un resultado satisfactorio en la escala KSS (72.2 ± 9.4), con diferencias significativas respecto al KSS previo (54.3 ± 8.9). Se obtuvo también una puntuación de 31 (12-67) en la escala FJS. Presentaron complicaciones postoperatorias 16.7% de los pacientes. Conclusiones: la cirugía de revisión protésica compleja mediante prótesis tipo bisagra rotacional constituye una correcta opción terapéutica, presentando resultados clínicos y funcionales adecuados, no exentos de complicaciones. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Acta Ortopédica Mexicana is the property of Sociedad Mexicana de Ortopedia, AC and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=177542575
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.35366/115809
    Languages:
      – Code: spa
        Text: Spanish
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 149
    Titles:
      – TitleFull: Prótesis bisagra rotatoria GMK. Una opción válida para la cirugía de revisión protésica compleja de rodilla.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Garrido-Ferrera, J. F.
      – PersonEntity:
          Name:
            NameFull: Marquina-Moraleda, V.
      – PersonEntity:
          Name:
            NameFull: Marco-Díaz, L.
      – PersonEntity:
          Name:
            NameFull: Colomina-Rodríguez, R.
      – PersonEntity:
          Name:
            NameFull: Hernández-Ferrando, L.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Text: may/jun2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 23064102
          Numbering:
            – Type: volume
              Value: 38
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Acta Ortopédica Mexicana
              Type: main
ResultId 1