Comparación de la fuerza y longitud de las cadenas elastoméricas termoestables y termoplásticas.

Saved in:
Bibliographic Details
Title: Comparación de la fuerza y longitud de las cadenas elastoméricas termoestables y termoplásticas.
Alternate Title: Comparison of strength and length of thermoset and thermoplastic elastomeric chains.
Authors: Cortés Campos, Jazmin1, Rivas Gutiérrez, Rafael2, Gutiérrez Rojo, Jaime3 jaime.gutierrez@uan.edu.mx, Masuoka Ito, David4, Barrera Bernal, José5
Source: Revista Kiru. ene-mar2025, Vol. 22 Issue 1, p12-17. 6p.
Subjects: STATISTICAL significance, ARTIFICIAL saliva, VERNIERS, DYNAMOMETER, TENSILE strength
Abstract (English): Objectives: To compare the strength and length of thermoset and thermoplastic elastomeric chains. Materials and Methods: An in vitro study was performed with a sample of 72 thermoplastic and 72 thermoset chains, divided into 6 times groups (initial, 1, 7, 14, 21 and 28 days). Thirty-six templates were manufactured with 20 mm separation. To hold the chains at a constant length; they were immersed in artificial saliva. Housed in an incubator at 37° C. Force was measured with a dynamometer and length with a digital vernier caliper. Student's t test, ANOVA and Tukey's post hoc test were performed. Results: The mean initial force of the thermoset chains (309.58 g) was lower than of the thermoplastic chains, and at 28 days the thermoplastic chains (322.5 g) had a greater loss of force (46.2%) and the thermoset chains 35%. The thermoplastic chains had greater dimensional changes (49.9%) and the thermoset chains 28.6% of their initial length. The strength and length showed statistically significant differences (p<0.001) from the first day. Conclusions: The thermoplastic chains had greater initial strength, while the thermoset chains obtained a lighter but more durable strength. The thermoplastic chains showed greater length changes from the first day. [ABSTRACT FROM AUTHOR]
Abstract (Spanish): Objetivos: Comparar la fuerza y longitud de las cadenas elastoméricas termoestables y termoplásticas. Materiales y Métodos: Se realizó un estudio in vitro con una muestra de 72 cadenas termoplásticas y 72 termoestables, divididas en 6 grupos de tiempo (inicial, 1, 7, 14, 21 y 28 días). Se fabricaron 36 plantillas con 20 mm de separación, para sujetar las cadenas a una longitud constante; se sumergieron en saliva artificial, alojadas en una incubadora a 37 °C. La fuerza se midió con un dinamómetro y la longitud con un calibrador vernier digital. Se realizaron pruebas de t de Student, ANOVA y post hoc de Tukey. Resultados: El promedio de la fuerza inicial de las cadenas termoestables (309,58 g) fue menor que las termoplásticas (322,5 g) y a los 28 días las termoplásticas tuvieron una pérdida de fuerza mayor (46,2%) que las termoestables (35%). Las cadenas termoplásticas tuvieron mayores cambios dimensionales (49,9%) y las termoestables el 28,6% de su longitud inicial. La fuerza y longitud presentaron diferencias estadísticamente significativas (p<0,001) a partir del primer día. Conclusiones: Las cadenas termoplásticas presentan mayor fuerza inicial, mientras que las cadenas termoestables obtuvieron una fuerza más ligera pero más duradera. Las cadenas termoplásticas presentaron mayores cambios de longitud desde el primer día. [ABSTRACT FROM AUTHOR]
Copyright of Revista Kiru is the property of Universidad de San Martin de Porres and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: MedicLatina
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: lth
DbLabel: MedicLatina
An: 183992928
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Comparaci&#243;n de la fuerza y longitud de las cadenas elastom&#233;ricas termoestables y termopl&#225;sticas.
– Name: TitleAlt
  Label: Alternate Title
  Group: TiAlt
  Data: Comparison of strength and length of thermoset and thermoplastic elastomeric chains.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Cort&#233;s+Campos%2C+Jazmin%22&quot;&gt;Cort&#233;s Campos, Jazmin&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Rivas+Guti&#233;rrez%2C+Rafael%22&quot;&gt;Rivas Guti&#233;rrez, Rafael&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Guti&#233;rrez+Rojo%2C+Jaime%22&quot;&gt;Guti&#233;rrez Rojo, Jaime&lt;/searchLink&gt;&lt;relatesTo&gt;3&lt;/relatesTo&gt;&lt;i&gt; jaime.gutierrez@uan.edu.mx&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Masuoka+Ito%2C+David%22&quot;&gt;Masuoka Ito, David&lt;/searchLink&gt;&lt;relatesTo&gt;4&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Barrera+Bernal%2C+Jos&#233;%22&quot;&gt;Barrera Bernal, Jos&#233;&lt;/searchLink&gt;&lt;relatesTo&gt;5&lt;/relatesTo&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Revista+Kiru%22&quot;&gt;Revista Kiru&lt;/searchLink&gt;. ene-mar2025, Vol. 22 Issue 1, p12-17. 6p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22STATISTICAL+significance%22&quot;&gt;STATISTICAL significance&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22ARTIFICIAL+saliva%22&quot;&gt;ARTIFICIAL saliva&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22VERNIERS%22&quot;&gt;VERNIERS&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22DYNAMOMETER%22&quot;&gt;DYNAMOMETER&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22TENSILE+strength%22&quot;&gt;TENSILE strength&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract (English)
  Group: Ab
  Data: Objectives: To compare the strength and length of thermoset and thermoplastic elastomeric chains. Materials and Methods: An in vitro study was performed with a sample of 72 thermoplastic and 72 thermoset chains, divided into 6 times groups (initial, 1, 7, 14, 21 and 28 days). Thirty-six templates were manufactured with 20 mm separation. To hold the chains at a constant length; they were immersed in artificial saliva. Housed in an incubator at 37&#176; C. Force was measured with a dynamometer and length with a digital vernier caliper. Student&#39;s t test, ANOVA and Tukey&#39;s post hoc test were performed. Results: The mean initial force of the thermoset chains (309.58 g) was lower than of the thermoplastic chains, and at 28 days the thermoplastic chains (322.5 g) had a greater loss of force (46.2%) and the thermoset chains 35%. The thermoplastic chains had greater dimensional changes (49.9%) and the thermoset chains 28.6% of their initial length. The strength and length showed statistically significant differences (p&lt;0.001) from the first day. Conclusions: The thermoplastic chains had greater initial strength, while the thermoset chains obtained a lighter but more durable strength. The thermoplastic chains showed greater length changes from the first day. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label: Abstract (Spanish)
  Group: Ab
  Data: Objetivos: Comparar la fuerza y longitud de las cadenas elastom&#233;ricas termoestables y termopl&#225;sticas. Materiales y M&#233;todos: Se realiz&#243; un estudio in vitro con una muestra de 72 cadenas termopl&#225;sticas y 72 termoestables, divididas en 6 grupos de tiempo (inicial, 1, 7, 14, 21 y 28 d&#237;as). Se fabricaron 36 plantillas con 20 mm de separaci&#243;n, para sujetar las cadenas a una longitud constante; se sumergieron en saliva artificial, alojadas en una incubadora a 37 &#176;C. La fuerza se midi&#243; con un dinam&#243;metro y la longitud con un calibrador vernier digital. Se realizaron pruebas de t de Student, ANOVA y post hoc de Tukey. Resultados: El promedio de la fuerza inicial de las cadenas termoestables (309,58 g) fue menor que las termopl&#225;sticas (322,5 g) y a los 28 d&#237;as las termopl&#225;sticas tuvieron una p&#233;rdida de fuerza mayor (46,2%) que las termoestables (35%). Las cadenas termopl&#225;sticas tuvieron mayores cambios dimensionales (49,9%) y las termoestables el 28,6% de su longitud inicial. La fuerza y longitud presentaron diferencias estad&#237;sticamente significativas (p&lt;0,001) a partir del primer d&#237;a. Conclusiones: Las cadenas termopl&#225;sticas presentan mayor fuerza inicial, mientras que las cadenas termoestables obtuvieron una fuerza m&#225;s ligera pero m&#225;s duradera. Las cadenas termopl&#225;sticas presentaron mayores cambios de longitud desde el primer d&#237;a. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Revista Kiru is the property of Universidad de San Martin de Porres and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=183992928
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.24265/kiru.2025.v22n1.03
    Languages:
      – Code: spa
        Text: Spanish
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 12
    Subjects:
      – SubjectFull: STATISTICAL significance
        Type: general
      – SubjectFull: ARTIFICIAL saliva
        Type: general
      – SubjectFull: VERNIERS
        Type: general
      – SubjectFull: DYNAMOMETER
        Type: general
      – SubjectFull: TENSILE strength
        Type: general
    Titles:
      – TitleFull: Comparación de la fuerza y longitud de las cadenas elastoméricas termoestables y termoplásticas.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Cortés Campos, Jazmin
      – PersonEntity:
          Name:
            NameFull: Rivas Gutiérrez, Rafael
      – PersonEntity:
          Name:
            NameFull: Gutiérrez Rojo, Jaime
      – PersonEntity:
          Name:
            NameFull: Masuoka Ito, David
      – PersonEntity:
          Name:
            NameFull: Barrera Bernal, José
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Text: ene-mar2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 18127886
          Numbering:
            – Type: volume
              Value: 22
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Revista Kiru
              Type: main
ResultId 1