Un análisis del efecto del volumen del cuerpo de la jeringa sobre la falla mecánica durante la inyección.

Saved in:
Bibliographic Details
Title: Un análisis del efecto del volumen del cuerpo de la jeringa sobre la falla mecánica durante la inyección.
Alternate Title: An analysis of the effect of syringe barrel volume on mechanical failure during injection.
Authors: Krisdiyanto1 krisdiyanto@umy.ac.id, Acknowledgment1
Source: Gaceta Médica Boliviana. ene-jun2025, Vol. 48 Issue 1, p77-82. 6p.
Subjects: SYRINGES, MECHANICAL failures, STRUCTURAL failures, SAFETY, INJECTIONS, MEDICAL equipment, YIELD stress
Abstract (English): Background: syringes are critical medical devices whose mechanical integrity is essential to ensure safety during injections. The cylinder volume can influence their mechanical performance. Objective: this study investigates how cylinder volume affects the mechanical integrity of syringes by analyzing von Mises stress, buckling risk, and overall safety during injection. Methods: autodesk Inventor 2021 and Ansys 2019 R2 were used to analyze syringes with volumes of 1 ml, 3 ml, 5 ml, and 10 ml. Von Mises stress and buckling susceptibility were evaluated during simulated injections. Results: smaller syringes showed higher stress levels: 14.030 MPa for the 1 ml syringe, 10.532 MPa for the 3 ml, and 7.0150 MPa for the 5 ml and 10 ml. The 5 ml syringe was the most susceptible to buckling, with a critical pressure of -0.1757 MPa. Despite this, all designs are safe under normal operating conditions. Conclusions: cylinder volume affects mechanical performance, but with proper design, even smaller syringes can remain safe, enhancing the reliability of medical treatments. [ABSTRACT FROM AUTHOR]
Abstract (Spanish): Antecedentes: las jeringas son dispositivos médicos críticos cuya integridad mecánica es esencial para garantizar su seguridad en las inyecciones. El volumen del cilindro puede influir en su rendimiento mecánico. Objetivo: este estudio investiga cómo el volumen del cilindro afecta la integridad mecánica de las jeringas, analizando el esfuerzo de von Mises, el riesgo de pandeo y la seguridad general durante la inyección. Métodos: se utilizaron Autodesk Inventor 2021 y Ansys 2019 R2 para analizar jeringas de 1 ml, 3 ml, 5 ml y 10 ml. Se evaluaron los esfuerzos de von Mises y la susceptibilidad al pandeo durante inyecciones simuladas. Resultados: las jeringas más pequeñas presentaron mayores esfuerzos: 14,030 MPa para la de 1 ml, 10,532 MPa para la de 3 ml y 7,0150 MPa para las de 5 ml y 10 ml. La jeringa de 5 ml fue la más susceptible al pandeo, con una presión crítica de -0,1757 MPa. A pesar de ello, todas son seguras bajo condiciones normales. Conclusiones: el volumen del cilindro afecta el rendimiento mecánico, pero con un buen diseño, incluso las jeringas pequeñas pueden ser seguras, mejorando la fiabilidad de los tratamientos médicos. [ABSTRACT FROM AUTHOR]
Copyright of Gaceta Médica Boliviana is the property of Universidad Mayor de San Simon, Facultad de Medicina and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: MedicLatina
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: lth
DbLabel: MedicLatina
An: 188788090
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Un análisis del efecto del volumen del cuerpo de la jeringa sobre la falla mecánica durante la inyección.
– Name: TitleAlt
  Label: Alternate Title
  Group: TiAlt
  Data: An analysis of the effect of syringe barrel volume on mechanical failure during injection.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Krisdiyanto%22">Krisdiyanto</searchLink><relatesTo>1</relatesTo><i> krisdiyanto@umy.ac.id</i><br /><searchLink fieldCode="AR" term="%22Acknowledgment%22">Acknowledgment</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Gaceta+Médica+Boliviana%22">Gaceta Médica Boliviana</searchLink>. ene-jun2025, Vol. 48 Issue 1, p77-82. 6p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22SYRINGES%22">SYRINGES</searchLink><br /><searchLink fieldCode="DE" term="%22MECHANICAL+failures%22">MECHANICAL failures</searchLink><br /><searchLink fieldCode="DE" term="%22STRUCTURAL+failures%22">STRUCTURAL failures</searchLink><br /><searchLink fieldCode="DE" term="%22SAFETY%22">SAFETY</searchLink><br /><searchLink fieldCode="DE" term="%22INJECTIONS%22">INJECTIONS</searchLink><br /><searchLink fieldCode="DE" term="%22MEDICAL+equipment%22">MEDICAL equipment</searchLink><br /><searchLink fieldCode="DE" term="%22YIELD+stress%22">YIELD stress</searchLink>
– Name: Abstract
  Label: Abstract (English)
  Group: Ab
  Data: Background: syringes are critical medical devices whose mechanical integrity is essential to ensure safety during injections. The cylinder volume can influence their mechanical performance. Objective: this study investigates how cylinder volume affects the mechanical integrity of syringes by analyzing von Mises stress, buckling risk, and overall safety during injection. Methods: autodesk Inventor 2021 and Ansys 2019 R2 were used to analyze syringes with volumes of 1 ml, 3 ml, 5 ml, and 10 ml. Von Mises stress and buckling susceptibility were evaluated during simulated injections. Results: smaller syringes showed higher stress levels: 14.030 MPa for the 1 ml syringe, 10.532 MPa for the 3 ml, and 7.0150 MPa for the 5 ml and 10 ml. The 5 ml syringe was the most susceptible to buckling, with a critical pressure of -0.1757 MPa. Despite this, all designs are safe under normal operating conditions. Conclusions: cylinder volume affects mechanical performance, but with proper design, even smaller syringes can remain safe, enhancing the reliability of medical treatments. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label: Abstract (Spanish)
  Group: Ab
  Data: Antecedentes: las jeringas son dispositivos médicos críticos cuya integridad mecánica es esencial para garantizar su seguridad en las inyecciones. El volumen del cilindro puede influir en su rendimiento mecánico. Objetivo: este estudio investiga cómo el volumen del cilindro afecta la integridad mecánica de las jeringas, analizando el esfuerzo de von Mises, el riesgo de pandeo y la seguridad general durante la inyección. Métodos: se utilizaron Autodesk Inventor 2021 y Ansys 2019 R2 para analizar jeringas de 1 ml, 3 ml, 5 ml y 10 ml. Se evaluaron los esfuerzos de von Mises y la susceptibilidad al pandeo durante inyecciones simuladas. Resultados: las jeringas más pequeñas presentaron mayores esfuerzos: 14,030 MPa para la de 1 ml, 10,532 MPa para la de 3 ml y 7,0150 MPa para las de 5 ml y 10 ml. La jeringa de 5 ml fue la más susceptible al pandeo, con una presión crítica de -0,1757 MPa. A pesar de ello, todas son seguras bajo condiciones normales. Conclusiones: el volumen del cilindro afecta el rendimiento mecánico, pero con un buen diseño, incluso las jeringas pequeñas pueden ser seguras, mejorando la fiabilidad de los tratamientos médicos. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Gaceta Médica Boliviana is the property of Universidad Mayor de San Simon, Facultad de Medicina and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=188788090
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.47993/gmb.v48i1.959
    Languages:
      – Code: spa
        Text: Spanish
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 77
    Subjects:
      – SubjectFull: SYRINGES
        Type: general
      – SubjectFull: MECHANICAL failures
        Type: general
      – SubjectFull: STRUCTURAL failures
        Type: general
      – SubjectFull: SAFETY
        Type: general
      – SubjectFull: INJECTIONS
        Type: general
      – SubjectFull: MEDICAL equipment
        Type: general
      – SubjectFull: YIELD stress
        Type: general
    Titles:
      – TitleFull: Un análisis del efecto del volumen del cuerpo de la jeringa sobre la falla mecánica durante la inyección.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Krisdiyanto
      – PersonEntity:
          Name:
            NameFull: Acknowledgment
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Text: ene-jun2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 10122966
          Numbering:
            – Type: volume
              Value: 48
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Gaceta Médica Boliviana
              Type: main
ResultId 1