Uso de la técnica de armónicos de corriente alterna en el estudio y comparación de la corrosión en el acero de refuerzo.
Saved in:
| Title: | Uso de la técnica de armónicos de corriente alterna en el estudio y comparación de la corrosión en el acero de refuerzo. |
|---|---|
| Authors: | Castañeda-Valdés, Abel1 abel.castaneda@cnic.edu.cu, Valdés-Clemente, Cecilia1, Corvo-Pérez., Francisco2 corvo@imre.oc.uh.cu |
| Source: | Revista CENIC Ciencias Quimicas. 2010, Vol. 41 Issue 2, p113-121. 9p. |
| Subjects: | STEEL corrosion, CONSTRUCTION materials, SOLID state chemistry, CHLORIDES, ELECTRICAL harmonics |
| Abstract (English): | The harmonic alternating current technique has not been used in corrosion studies in the reinforcing steel or other metallic material against an aggressive environment in Cuba. The main objective of this paper was to demonstrate that the alternating current harmonic technique can be used in the study and comparison of the reinforcement steel corrosion. A comparison between the corrosion potential obtained with this technique and steady corrosion potential, as well as between the corrosion rate obtained electrochemically and the direct measurement from the weight loss in the reinforcement steel in six probes of reinforcing concrete, was carried out. These probes of three different water/cement ratios were subjected to weather conditions and full immersion. Both conditions enabled the direct influence of chloride ions during three years of exposure. The results showed that the alternating current harmonic technique can be used in the study and comparison of reinforcing steel corrosion under chloride ion influence. The corrosion rate values obtained allowed demonstrating according to comparative statistical analysis that the factors that more could influence in the corrosion of reinforcing steel are the aggressive environment and its interaction with the water/cement ratio. [ABSTRACT FROM AUTHOR] |
| Abstract (Spanish): | La técnica de armónicos de corriente alterna no ha sido empleada en estudios de la corrosión del acero de refuerzo ni en cualquier otro material metálico frente a un medio agresivo en Cuba. El objetivo principal de este trabajo fue demostrar que esta técnica puede ser utilizada en el estudio y comparación de la corrosión del acero de refuerzo en el hormigón armado. Se realizó una comparación entre el potencial de corrosión obtenido con esta técnica y el estacionario de corrosión, así como entre la velocidad de corrosión, obtenida por vía electroquímica y la medida directa a partir de la pérdida de peso en los aceros de refuerzo en seis probetas de hormigón armado. Estas probetas de tres relaciones agua /cemento diferentes fueron sometidas a condiciones de intemperie e inmersión completa. Ambos medios agresivos posibilitaron la influencia directa de los iones cloruro durante tres años de exposición. Los resultados demostraron que la técnica de armónicos de corriente alterna puede ser usada en el estudio y comparación de la corrosión en el acero de refuerzo bajo la influencia de los iones cloruro. La magnitud obtenida de la velocidad de corrosión permitió demostrar, de acuerdo con el análisis estadístico comparativo, que los factores que más pudieran influir en la corrosión del acero de refuerzo son el medio agresivo y su interacción con la relación agua/cemento. [ABSTRACT FROM AUTHOR] |
| Copyright of Revista CENIC Ciencias Quimicas is the property of Centro Nacional de Investigaciones Cientificas and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | MedicLatina |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: lth DbLabel: MedicLatina An: 74732769 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Uso de la técnica de armónicos de corriente alterna en el estudio y comparación de la corrosión en el acero de refuerzo. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Castañeda-Valdés%2C+Abel%22">Castañeda-Valdés, Abel</searchLink><relatesTo>1</relatesTo><i> abel.castaneda@cnic.edu.cu</i><br /><searchLink fieldCode="AR" term="%22Valdés-Clemente%2C+Cecilia%22">Valdés-Clemente, Cecilia</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Corvo-Pérez%2E%2C+Francisco%22">Corvo-Pérez., Francisco</searchLink><relatesTo>2</relatesTo><i> corvo@imre.oc.uh.cu</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Revista+CENIC+Ciencias+Quimicas%22">Revista CENIC Ciencias Quimicas</searchLink>. 2010, Vol. 41 Issue 2, p113-121. 9p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22STEEL+corrosion%22">STEEL corrosion</searchLink><br /><searchLink fieldCode="DE" term="%22CONSTRUCTION+materials%22">CONSTRUCTION materials</searchLink><br /><searchLink fieldCode="DE" term="%22SOLID+state+chemistry%22">SOLID state chemistry</searchLink><br /><searchLink fieldCode="DE" term="%22CHLORIDES%22">CHLORIDES</searchLink><br /><searchLink fieldCode="DE" term="%22ELECTRICAL+harmonics%22">ELECTRICAL harmonics</searchLink> – Name: Abstract Label: Abstract (English) Group: Ab Data: The harmonic alternating current technique has not been used in corrosion studies in the reinforcing steel or other metallic material against an aggressive environment in Cuba. The main objective of this paper was to demonstrate that the alternating current harmonic technique can be used in the study and comparison of the reinforcement steel corrosion. A comparison between the corrosion potential obtained with this technique and steady corrosion potential, as well as between the corrosion rate obtained electrochemically and the direct measurement from the weight loss in the reinforcement steel in six probes of reinforcing concrete, was carried out. These probes of three different water/cement ratios were subjected to weather conditions and full immersion. Both conditions enabled the direct influence of chloride ions during three years of exposure. The results showed that the alternating current harmonic technique can be used in the study and comparison of reinforcing steel corrosion under chloride ion influence. The corrosion rate values obtained allowed demonstrating according to comparative statistical analysis that the factors that more could influence in the corrosion of reinforcing steel are the aggressive environment and its interaction with the water/cement ratio. [ABSTRACT FROM AUTHOR] – Name: Abstract Label: Abstract (Spanish) Group: Ab Data: La técnica de armónicos de corriente alterna no ha sido empleada en estudios de la corrosión del acero de refuerzo ni en cualquier otro material metálico frente a un medio agresivo en Cuba. El objetivo principal de este trabajo fue demostrar que esta técnica puede ser utilizada en el estudio y comparación de la corrosión del acero de refuerzo en el hormigón armado. Se realizó una comparación entre el potencial de corrosión obtenido con esta técnica y el estacionario de corrosión, así como entre la velocidad de corrosión, obtenida por vía electroquímica y la medida directa a partir de la pérdida de peso en los aceros de refuerzo en seis probetas de hormigón armado. Estas probetas de tres relaciones agua /cemento diferentes fueron sometidas a condiciones de intemperie e inmersión completa. Ambos medios agresivos posibilitaron la influencia directa de los iones cloruro durante tres años de exposición. Los resultados demostraron que la técnica de armónicos de corriente alterna puede ser usada en el estudio y comparación de la corrosión en el acero de refuerzo bajo la influencia de los iones cloruro. La magnitud obtenida de la velocidad de corrosión permitió demostrar, de acuerdo con el análisis estadístico comparativo, que los factores que más pudieran influir en la corrosión del acero de refuerzo son el medio agresivo y su interacción con la relación agua/cemento. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Revista CENIC Ciencias Quimicas is the property of Centro Nacional de Investigaciones Cientificas and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=74732769 |
| RecordInfo | BibRecord: BibEntity: Languages: – Code: spa Text: Spanish PhysicalDescription: Pagination: PageCount: 9 StartPage: 113 Subjects: – SubjectFull: STEEL corrosion Type: general – SubjectFull: CONSTRUCTION materials Type: general – SubjectFull: SOLID state chemistry Type: general – SubjectFull: CHLORIDES Type: general – SubjectFull: ELECTRICAL harmonics Type: general Titles: – TitleFull: Uso de la técnica de armónicos de corriente alterna en el estudio y comparación de la corrosión en el acero de refuerzo. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Castañeda-Valdés, Abel – PersonEntity: Name: NameFull: Valdés-Clemente, Cecilia – PersonEntity: Name: NameFull: Corvo-Pérez., Francisco IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 08 Text: 2010 Type: published Y: 2010 Identifiers: – Type: issn-print Value: 10158553 Numbering: – Type: volume Value: 41 – Type: issue Value: 2 Titles: – TitleFull: Revista CENIC Ciencias Quimicas Type: main |
| ResultId | 1 |