Caracterización de los niveles de exposición a campos electromagnéticos durante el tratamiento con diatermia.
Saved in:
| Title: | Caracterización de los niveles de exposición a campos electromagnéticos durante el tratamiento con diatermia. |
|---|---|
| Alternate Title: | Characterization of the exposure levels to electromagnetic fields during the diathermy treatment. |
| Authors: | Yero, Douglas Deás1 douglas@cnea.uo.edu.cu, González, Fidel Gilart1, Revilla, Daikel Quintana1 |
| Source: | MEDISAN. 2013, Vol. 17 Issue 6, p908-914. 7p. |
| Subjects: | SHORTWAVE therapy, DIATHERMY, ELECTROMAGNETIC fields, PHYSICAL therapy, PHYSIOLOGICAL therapeutics |
| Abstract (English): | A study of the electromagnetic field generated by different electrodes of capacitive type, used by the physiotherapy device for short wave diathermy (YB4-66), was carried out considering their interaction with the surrounding environment. The measurements of the electric field for different treatment configurations were carried out and a meter with electric isotropic field probe was used. By means of a professional software of simulation, a two-dimensional parametric electromagnetic model with axial symmetry was designed, to obtain detailedly in each configuration of the evaluated electrodes the interaction of the electromagnetic field with the biological tissue and the external environment. A good correspondence was found between the obtained results in an experimental way and the simulations, which allowed to identify the exposure levels and to make decisions to achieve a more effective treatment and with the shortest possible damage for the human beings. [ABSTRACT FROM AUTHOR] |
| Abstract (Spanish): | Se realizó un estudio del campo electromagnético generado por distintos electrodos de tipo capacitivo, empleados en el equipo de fisioterapia por diatermia de onda corta YB4-66, considerando su interacción con el medio ambiente que le rodea. Se realizaron las mediciones de campo eléctrico para diferentes configuraciones de tratamiento y se utilizó un medidor de campo eléctrico de sonda isotrópica. Se diseñó, mediante un software profesional de simulación, un modelo electromagnético paramétrico bidimensional con simetría axial, para obtener detalladamente en cada configuración de los electrodos evaluados la interacción del campo electromagnético con el tejido biológico y el ambiente exterior. Se halló una buena correspondencia entre los resultados obtenidos de forma experimental y las simulaciones, lo cual permitió identificar los niveles de exposición y tomar decisiones para lograr un tratamiento más efectivo y con el menor daño posible a los seres humanos. [ABSTRACT FROM AUTHOR] |
| Copyright of MEDISAN is the property of Centro Provincial de Informacion en Ciencias Medicas de Santiago de Cuba and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | MedicLatina |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: lth DbLabel: MedicLatina An: 92944514 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Caracterización de los niveles de exposición a campos electromagnéticos durante el tratamiento con diatermia. – Name: TitleAlt Label: Alternate Title Group: TiAlt Data: Characterization of the exposure levels to electromagnetic fields during the diathermy treatment. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Yero%2C+Douglas+Deás%22">Yero, Douglas Deás</searchLink><relatesTo>1</relatesTo><i> douglas@cnea.uo.edu.cu</i><br /><searchLink fieldCode="AR" term="%22González%2C+Fidel+Gilart%22">González, Fidel Gilart</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Revilla%2C+Daikel+Quintana%22">Revilla, Daikel Quintana</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22MEDISAN%22">MEDISAN</searchLink>. 2013, Vol. 17 Issue 6, p908-914. 7p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22SHORTWAVE+therapy%22">SHORTWAVE therapy</searchLink><br /><searchLink fieldCode="DE" term="%22DIATHERMY%22">DIATHERMY</searchLink><br /><searchLink fieldCode="DE" term="%22ELECTROMAGNETIC+fields%22">ELECTROMAGNETIC fields</searchLink><br /><searchLink fieldCode="DE" term="%22PHYSICAL+therapy%22">PHYSICAL therapy</searchLink><br /><searchLink fieldCode="DE" term="%22PHYSIOLOGICAL+therapeutics%22">PHYSIOLOGICAL therapeutics</searchLink> – Name: Abstract Label: Abstract (English) Group: Ab Data: A study of the electromagnetic field generated by different electrodes of capacitive type, used by the physiotherapy device for short wave diathermy (YB4-66), was carried out considering their interaction with the surrounding environment. The measurements of the electric field for different treatment configurations were carried out and a meter with electric isotropic field probe was used. By means of a professional software of simulation, a two-dimensional parametric electromagnetic model with axial symmetry was designed, to obtain detailedly in each configuration of the evaluated electrodes the interaction of the electromagnetic field with the biological tissue and the external environment. A good correspondence was found between the obtained results in an experimental way and the simulations, which allowed to identify the exposure levels and to make decisions to achieve a more effective treatment and with the shortest possible damage for the human beings. [ABSTRACT FROM AUTHOR] – Name: Abstract Label: Abstract (Spanish) Group: Ab Data: Se realizó un estudio del campo electromagnético generado por distintos electrodos de tipo capacitivo, empleados en el equipo de fisioterapia por diatermia de onda corta YB4-66, considerando su interacción con el medio ambiente que le rodea. Se realizaron las mediciones de campo eléctrico para diferentes configuraciones de tratamiento y se utilizó un medidor de campo eléctrico de sonda isotrópica. Se diseñó, mediante un software profesional de simulación, un modelo electromagnético paramétrico bidimensional con simetría axial, para obtener detalladamente en cada configuración de los electrodos evaluados la interacción del campo electromagnético con el tejido biológico y el ambiente exterior. Se halló una buena correspondencia entre los resultados obtenidos de forma experimental y las simulaciones, lo cual permitió identificar los niveles de exposición y tomar decisiones para lograr un tratamiento más efectivo y con el menor daño posible a los seres humanos. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of MEDISAN is the property of Centro Provincial de Informacion en Ciencias Medicas de Santiago de Cuba and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=92944514 |
| RecordInfo | BibRecord: BibEntity: Languages: – Code: spa Text: Spanish PhysicalDescription: Pagination: PageCount: 7 StartPage: 908 Subjects: – SubjectFull: SHORTWAVE therapy Type: general – SubjectFull: DIATHERMY Type: general – SubjectFull: ELECTROMAGNETIC fields Type: general – SubjectFull: PHYSICAL therapy Type: general – SubjectFull: PHYSIOLOGICAL therapeutics Type: general Titles: – TitleFull: Caracterización de los niveles de exposición a campos electromagnéticos durante el tratamiento con diatermia. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Yero, Douglas Deás – PersonEntity: Name: NameFull: González, Fidel Gilart – PersonEntity: Name: NameFull: Revilla, Daikel Quintana IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 06 Text: 2013 Type: published Y: 2013 Identifiers: – Type: issn-print Value: 10293019 Numbering: – Type: volume Value: 17 – Type: issue Value: 6 Titles: – TitleFull: MEDISAN Type: main |
| ResultId | 1 |