What is behind radiofrequency delivery at the cavo-tricuspid isthmus?
Saved in:
| Title: | What is behind radiofrequency delivery at the cavo-tricuspid isthmus? |
|---|---|
| Alternate Title: | ¿Qué sucede en el istmo cavo-tricuspídeo durante la ablación con radiofreuencia? |
| Authors: | Filgueiras-Rama, David1, Arceluz, Martín1, Castrejón, Sergio1, Estrada, Alejandro1, Figueroa, Jorge1, Ortega-Molina, Marta1, Delgado, Reina1, Merino, José L.1 jlmerino@arritmias.net |
| Source: | Archivos de Cardiología de México. ene-mar2014, Vol. 84 Issue 1, p51-52. 2p. 1 Black and White Photograph. |
| Subjects: | RADIO frequency, HEART abnormalities, HEART conduction system, CATHETERS, EDEMA, ATRIAL flutter, PHYSIOLOGY |
| Abstract (English): | Catheter-based ablation of isthmus-dependent common atrial flutter results in very high success rates and almost no complications. However, bidirectional conduction block through the isthmus may be challenging in a small percentage of patients regarding the use of high power and high temperature settings during radiofrequency delivery. Anatomical and physiological circumstances may be the reason for such difficulties to achieve bidirectional block at the cavo-tricuspid isthmus. However, in the present case we show edema formation after multiple shots of radiofrequency delivery at the cavo-tricuspid isthmus, which complicates the achievement of bidirectional conduction block. [ABSTRACT FROM AUTHOR] |
| Abstract (Spanish): | La ablación con catéter del flutter de tipo común dependiente del istmo es un procedimiento con elevada tasa de éxito y rara vez complicaciones. Sin embargo, en un pequeño porcentaje de casos puede resultar complicado conseguir el objetivo de bloquear bidireccionalmente el istmo durante el procedimiento de ablación a pesar de incrementar la potencia y temperatura del catéter de radiofrecuencia. Las características anatómicas y fisiológicas del istmo cavo-tricuspídeo pueden ocasionar dificultades en la consecución del bloqueo bidireccional. Sin embargo, en el presente caso mostramos cómo la propia aplicación de radiofrecuencia puede ocasionar edema importante tras múltiples aplicaciones con las consiguientes dificultades para conseguir el bloqueo bidireccional del istmo. [ABSTRACT FROM AUTHOR] |
| Copyright of Archivos de Cardiología de México is the property of Publicidad Permanyer SLU and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | MedicLatina |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: lth DbLabel: MedicLatina An: 95874469 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: What is behind radiofrequency delivery at the cavo-tricuspid isthmus? – Name: TitleAlt Label: Alternate Title Group: TiAlt Data: ¿Qué sucede en el istmo cavo-tricuspídeo durante la ablación con radiofreuencia? – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Filgueiras-Rama%2C+David%22">Filgueiras-Rama, David</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Arceluz%2C+Martín%22">Arceluz, Martín</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Castrejón%2C+Sergio%22">Castrejón, Sergio</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Estrada%2C+Alejandro%22">Estrada, Alejandro</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Figueroa%2C+Jorge%22">Figueroa, Jorge</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Ortega-Molina%2C+Marta%22">Ortega-Molina, Marta</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Delgado%2C+Reina%22">Delgado, Reina</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Merino%2C+José+L%2E%22">Merino, José L.</searchLink><relatesTo>1</relatesTo><i> jlmerino@arritmias.net</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Archivos+de+Cardiología+de+México%22">Archivos de Cardiología de México</searchLink>. ene-mar2014, Vol. 84 Issue 1, p51-52. 2p. 1 Black and White Photograph. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22RADIO+frequency%22">RADIO frequency</searchLink><br /><searchLink fieldCode="DE" term="%22HEART+abnormalities%22">HEART abnormalities</searchLink><br /><searchLink fieldCode="DE" term="%22HEART+conduction+system%22">HEART conduction system</searchLink><br /><searchLink fieldCode="DE" term="%22CATHETERS%22">CATHETERS</searchLink><br /><searchLink fieldCode="DE" term="%22EDEMA%22">EDEMA</searchLink><br /><searchLink fieldCode="DE" term="%22ATRIAL+flutter%22">ATRIAL flutter</searchLink><br /><searchLink fieldCode="DE" term="%22PHYSIOLOGY%22">PHYSIOLOGY</searchLink> – Name: Abstract Label: Abstract (English) Group: Ab Data: Catheter-based ablation of isthmus-dependent common atrial flutter results in very high success rates and almost no complications. However, bidirectional conduction block through the isthmus may be challenging in a small percentage of patients regarding the use of high power and high temperature settings during radiofrequency delivery. Anatomical and physiological circumstances may be the reason for such difficulties to achieve bidirectional block at the cavo-tricuspid isthmus. However, in the present case we show edema formation after multiple shots of radiofrequency delivery at the cavo-tricuspid isthmus, which complicates the achievement of bidirectional conduction block. [ABSTRACT FROM AUTHOR] – Name: Abstract Label: Abstract (Spanish) Group: Ab Data: La ablación con catéter del flutter de tipo común dependiente del istmo es un procedimiento con elevada tasa de éxito y rara vez complicaciones. Sin embargo, en un pequeño porcentaje de casos puede resultar complicado conseguir el objetivo de bloquear bidireccionalmente el istmo durante el procedimiento de ablación a pesar de incrementar la potencia y temperatura del catéter de radiofrecuencia. Las características anatómicas y fisiológicas del istmo cavo-tricuspídeo pueden ocasionar dificultades en la consecución del bloqueo bidireccional. Sin embargo, en el presente caso mostramos cómo la propia aplicación de radiofrecuencia puede ocasionar edema importante tras múltiples aplicaciones con las consiguientes dificultades para conseguir el bloqueo bidireccional del istmo. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Archivos de Cardiología de México is the property of Publicidad Permanyer SLU and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=95874469 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.acmx.2013.07.007 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 2 StartPage: 51 Subjects: – SubjectFull: RADIO frequency Type: general – SubjectFull: HEART abnormalities Type: general – SubjectFull: HEART conduction system Type: general – SubjectFull: CATHETERS Type: general – SubjectFull: EDEMA Type: general – SubjectFull: ATRIAL flutter Type: general – SubjectFull: PHYSIOLOGY Type: general Titles: – TitleFull: What is behind radiofrequency delivery at the cavo-tricuspid isthmus? Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Filgueiras-Rama, David – PersonEntity: Name: NameFull: Arceluz, Martín – PersonEntity: Name: NameFull: Castrejón, Sergio – PersonEntity: Name: NameFull: Estrada, Alejandro – PersonEntity: Name: NameFull: Figueroa, Jorge – PersonEntity: Name: NameFull: Ortega-Molina, Marta – PersonEntity: Name: NameFull: Delgado, Reina – PersonEntity: Name: NameFull: Merino, José L. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Text: ene-mar2014 Type: published Y: 2014 Identifiers: – Type: issn-print Value: 14059940 Numbering: – Type: volume Value: 84 – Type: issue Value: 1 Titles: – TitleFull: Archivos de Cardiología de México Type: main |
| ResultId | 1 |