Determination of lipid content and stability in lipid nanoparticles using ultra high-performance liquid chromatography in combination with a Corona Charged Aerosol Detector.
Saved in:
| Title: | Determination of lipid content and stability in lipid nanoparticles using ultra high-performance liquid chromatography in combination with a Corona Charged Aerosol Detector. |
|---|---|
| Authors: | Kinsey C; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA., Lu T; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA., Deiss A; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA., Vuolo K; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA., Klein L; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA., Rustandi RR; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA., Loughney JW; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA. |
| Source: | Electrophoresis [Electrophoresis] 2022 May; Vol. 43 (9-10), pp. 1091-1100. Date of Electronic Publication: 2021 Dec 21. |
| Publication Type: | Journal Article |
| Journal Info: | Publisher: Wiley-VCH Country of Publication: Germany NLM ID: 8204476 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1522-2683 (Electronic) Linking ISSN: 01730835 NLM ISO Abbreviation: Electrophoresis Subsets: MEDLINE |
| Database: | MEDLINE Ultimate |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: mdl DbLabel: MEDLINE Ultimate An: 34784061 AccessLevel: 2 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Determination of lipid content and stability in lipid nanoparticles using ultra high-performance liquid chromatography in combination with a Corona Charged Aerosol Detector. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Kinsey+C%22">Kinsey C</searchLink>; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA.<br /><searchLink fieldCode="AU" term="%22Lu+T%22">Lu T</searchLink>; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA.<br /><searchLink fieldCode="AU" term="%22Deiss+A%22">Deiss A</searchLink>; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA.<br /><searchLink fieldCode="AU" term="%22Vuolo+K%22">Vuolo K</searchLink>; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA.<br /><searchLink fieldCode="AU" term="%22Klein+L%22">Klein L</searchLink>; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA.<br /><searchLink fieldCode="AU" term="%22Rustandi+RR%22">Rustandi RR</searchLink>; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA.<br /><searchLink fieldCode="AU" term="%22Loughney+JW%22">Loughney JW</searchLink>; Vaccine Analytical Research & Development, Merck & Co. Inc., West Point, Pennsylvania, USA. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%228204476%22">Electrophoresis</searchLink> [Electrophoresis] 2022 May; Vol. 43 (9-10), pp. 1091-1100. <i>Date of Electronic Publication: </i>2021 Dec 21. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Wiley-VCH%22">Wiley-VCH </searchLink><i>Country of Publication: </i>Germany <i>NLM ID: </i>8204476 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1522-2683 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2201730835%22">01730835 </searchLink><i>NLM ISO Abbreviation: </i>Electrophoresis <i>Subsets: </i>MEDLINE |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=mdl&AN=34784061 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/elps.202100244 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 1091 Titles: – TitleFull: Determination of lipid content and stability in lipid nanoparticles using ultra high-performance liquid chromatography in combination with a Corona Charged Aerosol Detector. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Kinsey C – PersonEntity: Name: NameFull: Lu T – PersonEntity: Name: NameFull: Deiss A – PersonEntity: Name: NameFull: Vuolo K – PersonEntity: Name: NameFull: Klein L – PersonEntity: Name: NameFull: Rustandi RR – PersonEntity: Name: NameFull: Loughney JW IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 05 Text: 2022 May Type: published Y: 2022 Identifiers: – Type: issn-electronic Value: 1522-2683 Numbering: – Type: volume Value: 43 – Type: issue Value: 9-10 Titles: – TitleFull: Electrophoresis Type: main |
| ResultId | 1 |