Improved Satisfaction While Maintaining Safety and High Time in Range (TIR) With a Medtronic Investigational Enhanced Advanced Hybrid Closed-Loop (e-AHCL) System.

Saved in:
Bibliographic Details
Title: Improved Satisfaction While Maintaining Safety and High Time in Range (TIR) With a Medtronic Investigational Enhanced Advanced Hybrid Closed-Loop (e-AHCL) System.
Authors: Yuan CY; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia., Kong YW; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia., Amoore T; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia., Brown K; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia., Grosman B; Medtronic, Northridge, CA., Jenkins A; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; The Baker Institute, Prahran, Victoria, Australia.; The Australian Centre for Accelerating Diabetes Innovations, Melbourne, Victoria, Australia., Jones H; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia., Kurtz N; Medtronic, Northridge, CA., Lee MH; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia., MacIsaac R; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; The Australian Centre for Accelerating Diabetes Innovations, Melbourne, Victoria, Australia., Netzer E; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia., Paldus B; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia., Robinson L; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia., Roy A; Medtronic, Northridge, CA., Sims CM; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia., Trawley S; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Cairnmiller Institute, Hawthorn East, Victoria, Australia., Vogrin S; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia., O'Neal DN; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; The Australian Centre for Accelerating Diabetes Innovations, Melbourne, Victoria, Australia.
Source: Diabetes care [Diabetes Care] 2024 Apr 01; Vol. 47 (4), pp. 747-755.
Publication Type: Clinical Trial; Journal Article
Journal Info: Publisher: American Diabetes Association Country of Publication: United States NLM ID: 7805975 Publication Model: Print Cited Medium: Internet ISSN: 1935-5548 (Electronic) Linking ISSN: 01495992 NLM ISO Abbreviation: Diabetes Care Subsets: MEDLINE
Database: MEDLINE Ultimate
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: mdl
DbLabel: MEDLINE Ultimate
An: 38381515
AccessLevel: 2
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Improved Satisfaction While Maintaining Safety and High Time in Range (TIR) With a Medtronic Investigational Enhanced Advanced Hybrid Closed-Loop (e-AHCL) System.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AU" term="%22Yuan+CY%22">Yuan CY</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Kong+YW%22">Kong YW</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Amoore+T%22">Amoore T</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Brown+K%22">Brown K</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Grosman+B%22">Grosman B</searchLink>; Medtronic, Northridge, CA.<br /><searchLink fieldCode="AU" term="%22Jenkins+A%22">Jenkins A</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; The Baker Institute, Prahran, Victoria, Australia.; The Australian Centre for Accelerating Diabetes Innovations, Melbourne, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Jones+H%22">Jones H</searchLink>; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Kurtz+N%22">Kurtz N</searchLink>; Medtronic, Northridge, CA.<br /><searchLink fieldCode="AU" term="%22Lee+MH%22">Lee MH</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22MacIsaac+R%22">MacIsaac R</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; The Australian Centre for Accelerating Diabetes Innovations, Melbourne, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Netzer+E%22">Netzer E</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Paldus+B%22">Paldus B</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Robinson+L%22">Robinson L</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Roy+A%22">Roy A</searchLink>; Medtronic, Northridge, CA.<br /><searchLink fieldCode="AU" term="%22Sims+CM%22">Sims CM</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Trawley+S%22">Trawley S</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Cairnmiller Institute, Hawthorn East, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Vogrin+S%22">Vogrin S</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22O'Neal+DN%22">O'Neal DN</searchLink>; University of Melbourne Department of Medicine, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; Department of Endocrinology, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.; The Australian Centre for Accelerating Diabetes Innovations, Melbourne, Victoria, Australia.
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%227805975%22">Diabetes care</searchLink> [Diabetes Care] 2024 Apr 01; Vol. 47 (4), pp. 747-755.
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Clinical Trial; Journal Article
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22American+Diabetes+Association%22">American Diabetes Association </searchLink><i>Country of Publication: </i>United States <i>NLM ID: </i>7805975 <i>Publication Model: </i>Print <i>Cited Medium: </i>Internet <i>ISSN: </i>1935-5548 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2201495992%22">01495992 </searchLink><i>NLM ISO Abbreviation: </i>Diabetes Care <i>Subsets: </i>MEDLINE
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=mdl&AN=38381515
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.2337/dc23-2217
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        StartPage: 747
    Titles:
      – TitleFull: Improved Satisfaction While Maintaining Safety and High Time in Range (TIR) With a Medtronic Investigational Enhanced Advanced Hybrid Closed-Loop (e-AHCL) System.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Yuan CY
      – PersonEntity:
          Name:
            NameFull: Kong YW
      – PersonEntity:
          Name:
            NameFull: Amoore T
      – PersonEntity:
          Name:
            NameFull: Brown K
      – PersonEntity:
          Name:
            NameFull: Grosman B
      – PersonEntity:
          Name:
            NameFull: Jenkins A
      – PersonEntity:
          Name:
            NameFull: Jones H
      – PersonEntity:
          Name:
            NameFull: Kurtz N
      – PersonEntity:
          Name:
            NameFull: Lee MH
      – PersonEntity:
          Name:
            NameFull: MacIsaac R
      – PersonEntity:
          Name:
            NameFull: Netzer E
      – PersonEntity:
          Name:
            NameFull: Paldus B
      – PersonEntity:
          Name:
            NameFull: Robinson L
      – PersonEntity:
          Name:
            NameFull: Roy A
      – PersonEntity:
          Name:
            NameFull: Sims CM
      – PersonEntity:
          Name:
            NameFull: Trawley S
      – PersonEntity:
          Name:
            NameFull: Vogrin S
      – PersonEntity:
          Name:
            NameFull: O'Neal DN
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: 2024 Apr 01
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-electronic
              Value: 1935-5548
          Numbering:
            – Type: volume
              Value: 47
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: Diabetes care
              Type: main
ResultId 1