Image Quality and Radiation Exposure in Abdominal Angiography: A Head-to-Head Comparison of Conventional Detector-Dose-Driven Versus Contrast-to-Noise Ratio-Driven Exposure Control at Various Source-to-Image Receptor Distances and Collimations in a Pilot Phantom and Animal Study.
Saved in:
| Title: | Image Quality and Radiation Exposure in Abdominal Angiography: A Head-to-Head Comparison of Conventional Detector-Dose-Driven Versus Contrast-to-Noise Ratio-Driven Exposure Control at Various Source-to-Image Receptor Distances and Collimations in a Pilot Phantom and Animal Study. |
|---|---|
| Authors: | Werncke T; From the Department of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany (T.W., L.S., S.K.M., T.C.M., C.L.A., F.K.W., B.C.M.); Department of Diagnostic and Interventional Radiology and Neuroradiology, St. Bernward Hospital, Hildesheim, Germany (J.B.H.); and Institute for Laboratory Animal Science and Central Animal Facility, Hannover Medical School, Hannover, Germany (I.B., R.R.)., Becker LS, Maschke SK, Hinrichs JB, Meine TCH, Dewald CLA, Brüsch I, Rumpel R, Wacker FK, Meyer BC |
| Source: | Investigative radiology [Invest Radiol] 2024 Oct 01; Vol. 59 (10), pp. 711-718. Date of Electronic Publication: 2024 Mar 27. |
| Publication Type: | Journal Article; Comparative Study; Research Support, Non-U.S. Gov't |
| Journal Info: | Publisher: Lippincott Williams & Wilkins Country of Publication: United States NLM ID: 0045377 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1536-0210 (Electronic) Linking ISSN: 00209996 NLM ISO Abbreviation: Invest Radiol Subsets: MEDLINE |
| Database: | MEDLINE Ultimate |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: mdl DbLabel: MEDLINE Ultimate An: 38529924 AccessLevel: 2 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Image Quality and Radiation Exposure in Abdominal Angiography: A Head-to-Head Comparison of Conventional Detector-Dose-Driven Versus Contrast-to-Noise Ratio-Driven Exposure Control at Various Source-to-Image Receptor Distances and Collimations in a Pilot Phantom and Animal Study. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Werncke+T%22">Werncke T</searchLink>; From the Department of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany (T.W., L.S., S.K.M., T.C.M., C.L.A., F.K.W., B.C.M.); Department of Diagnostic and Interventional Radiology and Neuroradiology, St. Bernward Hospital, Hildesheim, Germany (J.B.H.); and Institute for Laboratory Animal Science and Central Animal Facility, Hannover Medical School, Hannover, Germany (I.B., R.R.).<br /><searchLink fieldCode="AU" term="%22Becker+LS%22">Becker LS</searchLink><br /><searchLink fieldCode="AU" term="%22Maschke+SK%22">Maschke SK</searchLink><br /><searchLink fieldCode="AU" term="%22Hinrichs+JB%22">Hinrichs JB</searchLink><br /><searchLink fieldCode="AU" term="%22Meine+TCH%22">Meine TCH</searchLink><br /><searchLink fieldCode="AU" term="%22Dewald+CLA%22">Dewald CLA</searchLink><br /><searchLink fieldCode="AU" term="%22Brüsch+I%22">Brüsch I</searchLink><br /><searchLink fieldCode="AU" term="%22Rumpel+R%22">Rumpel R</searchLink><br /><searchLink fieldCode="AU" term="%22Wacker+FK%22">Wacker FK</searchLink><br /><searchLink fieldCode="AU" term="%22Meyer+BC%22">Meyer BC</searchLink> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%220045377%22">Investigative radiology</searchLink> [Invest Radiol] 2024 Oct 01; Vol. 59 (10), pp. 711-718. <i>Date of Electronic Publication: </i>2024 Mar 27. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article; Comparative Study; Research Support, Non-U.S. Gov't – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Lippincott+Williams+%26+Wilkins%22">Lippincott Williams & Wilkins </searchLink><i>Country of Publication: </i>United States <i>NLM ID: </i>0045377 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1536-0210 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200209996%22">00209996 </searchLink><i>NLM ISO Abbreviation: </i>Invest Radiol <i>Subsets: </i>MEDLINE |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=mdl&AN=38529924 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1097/RLI.0000000000001079 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 711 Titles: – TitleFull: Image Quality and Radiation Exposure in Abdominal Angiography: A Head-to-Head Comparison of Conventional Detector-Dose-Driven Versus Contrast-to-Noise Ratio-Driven Exposure Control at Various Source-to-Image Receptor Distances and Collimations in a Pilot Phantom and Animal Study. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Werncke T – PersonEntity: Name: NameFull: Becker LS – PersonEntity: Name: NameFull: Maschke SK – PersonEntity: Name: NameFull: Hinrichs JB – PersonEntity: Name: NameFull: Meine TCH – PersonEntity: Name: NameFull: Dewald CLA – PersonEntity: Name: NameFull: Brüsch I – PersonEntity: Name: NameFull: Rumpel R – PersonEntity: Name: NameFull: Wacker FK – PersonEntity: Name: NameFull: Meyer BC IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: 2024 Oct 01 Type: published Y: 2024 Identifiers: – Type: issn-electronic Value: 1536-0210 Numbering: – Type: volume Value: 59 – Type: issue Value: 10 Titles: – TitleFull: Investigative radiology Type: main |
| ResultId | 1 |