Comparison of early and late aseptic baseplate failure in primary reverse shoulder arthroplasty with and without structural glenoid autograft.

Saved in:
Bibliographic Details
Title: Comparison of early and late aseptic baseplate failure in primary reverse shoulder arthroplasty with and without structural glenoid autograft.
Authors: Lo EY; The Shoulder Center Research, Baylor Scott and White Research Institute, Dallas, TX, USA; The Shoulder Service, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX, USA. Electronic address: Eddie.Lo@BSWHealth.org., Witt A; The Shoulder Center Research, Baylor Scott and White Research Institute, Dallas, TX, USA; The Shoulder Service, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX, USA., Ouseph A; The Shoulder Center Research, Baylor Scott and White Research Institute, Dallas, TX, USA; The Shoulder Service, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX, USA., Montemaggi P; Department of Orthopaedics and Trauma Surgery, AOUP- Cisanello Hospital, University of Pisa, Pisa, Italy., Garofalo R; Upper Limb Unit, F. Miulli Hospital, Acquaviva Delle Fonti Ba, Italy., Sanders A; Department of Orthopedic Surgery, Oklahoma University Health Sciences Center, University of Oklahoma College of Medicine, Oklahoma City, OK, USA., Majekodunmi T; The Shoulder Center Research, Baylor Scott and White Research Institute, Dallas, TX, USA; The Shoulder Service, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX, USA., Sodl J; The Shoulder Center Research, Baylor Scott and White Research Institute, Dallas, TX, USA; The Shoulder Service, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX, USA., Krishnan SG; The Shoulder Center Research, Baylor Scott and White Research Institute, Dallas, TX, USA; The Shoulder Service, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX, USA.
Source: Journal of shoulder and elbow surgery [J Shoulder Elbow Surg] 2025 Mar; Vol. 34 (3), pp. 820-827. Date of Electronic Publication: 2024 Jul 25.
Publication Type: Journal Article; Comparative Study
Journal Info: Publisher: Mosby Country of Publication: United States NLM ID: 9206499 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1532-6500 (Electronic) Linking ISSN: 10582746 NLM ISO Abbreviation: J Shoulder Elbow Surg Subsets: MEDLINE
Database: MEDLINE Ultimate
Description
ISSN:1532-6500
DOI:10.1016/j.jse.2024.05.038