Mechanical effect of taper position in abutment hole and screw taper angles on implant system and peri-implant tissue: a finite element analysis.
Saved in:
| Title: | Mechanical effect of taper position in abutment hole and screw taper angles on implant system and peri-implant tissue: a finite element analysis. |
|---|---|
| Authors: | Hou H; School of Mechanical Engineering, Shanghai Institute of Technology, Fengxian, Shanghai, China., Zhang J; School of Mechanical Engineering, Shanghai Institute of Technology, Fengxian, Shanghai, China., Huang S; School of Mechanical Engineering, Shanghai Institute of Technology, Fengxian, Shanghai, China., Hu F; Department of Stomatology, Shanghai Geriatric Medical Center, Minhang, Shanghai, China.; Department of Stomatology, Zhongshan Hospital, Fudan University, Xuhui, Shanghai, China., Yu Y; Department of Stomatology, Zhongshan Hospital, Fudan University, Xuhui, Shanghai, China., Song L; Department of Stomatology, Shanghai Fifth People's Hospital, Fudan University, Minhang, Shanghai, China. |
| Source: | Computer methods in biomechanics and biomedical engineering [Comput Methods Biomech Biomed Engin] 2026 Apr; Vol. 29 (5), pp. 998-1006. Date of Electronic Publication: 2024 Nov 04. |
| Publication Type: | Journal Article |
| Journal Info: | Publisher: Informa Healthcare Country of Publication: England NLM ID: 9802899 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1476-8259 (Electronic) Linking ISSN: 10255842 NLM ISO Abbreviation: Comput Methods Biomech Biomed Engin Subsets: MEDLINE |
| Database: | MEDLINE Ultimate |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: mdl DbLabel: MEDLINE Ultimate An: 39492649 AccessLevel: 2 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Mechanical effect of taper position in abutment hole and screw taper angles on implant system and peri-implant tissue: a finite element analysis. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Hou+H%22">Hou H</searchLink>; School of Mechanical Engineering, Shanghai Institute of Technology, Fengxian, Shanghai, China.<br /><searchLink fieldCode="AU" term="%22Zhang+J%22">Zhang J</searchLink>; School of Mechanical Engineering, Shanghai Institute of Technology, Fengxian, Shanghai, China.<br /><searchLink fieldCode="AU" term="%22Huang+S%22">Huang S</searchLink>; School of Mechanical Engineering, Shanghai Institute of Technology, Fengxian, Shanghai, China.<br /><searchLink fieldCode="AU" term="%22Hu+F%22">Hu F</searchLink>; Department of Stomatology, Shanghai Geriatric Medical Center, Minhang, Shanghai, China.; Department of Stomatology, Zhongshan Hospital, Fudan University, Xuhui, Shanghai, China.<br /><searchLink fieldCode="AU" term="%22Yu+Y%22">Yu Y</searchLink>; Department of Stomatology, Zhongshan Hospital, Fudan University, Xuhui, Shanghai, China.<br /><searchLink fieldCode="AU" term="%22Song+L%22">Song L</searchLink>; Department of Stomatology, Shanghai Fifth People's Hospital, Fudan University, Minhang, Shanghai, China. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%229802899%22">Computer methods in biomechanics and biomedical engineering</searchLink> [Comput Methods Biomech Biomed Engin] 2026 Apr; Vol. 29 (5), pp. 998-1006. <i>Date of Electronic Publication: </i>2024 Nov 04. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Informa+Healthcare%22">Informa Healthcare </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>9802899 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1476-8259 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2210255842%22">10255842 </searchLink><i>NLM ISO Abbreviation: </i>Comput Methods Biomech Biomed Engin <i>Subsets: </i>MEDLINE |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=mdl&AN=39492649 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1080/10255842.2024.2423253 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 998 Titles: – TitleFull: Mechanical effect of taper position in abutment hole and screw taper angles on implant system and peri-implant tissue: a finite element analysis. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Hou H – PersonEntity: Name: NameFull: Zhang J – PersonEntity: Name: NameFull: Huang S – PersonEntity: Name: NameFull: Hu F – PersonEntity: Name: NameFull: Yu Y – PersonEntity: Name: NameFull: Song L IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 04 Text: 2026 Apr Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1476-8259 Numbering: – Type: volume Value: 29 – Type: issue Value: 5 Titles: – TitleFull: Computer methods in biomechanics and biomedical engineering Type: main |
| ResultId | 1 |