Automated Kidney Stone Composition Analysis with Photon-Counting Detector CT, a Performance Study-A Phantom Study.

Saved in:
Bibliographic Details
Title: Automated Kidney Stone Composition Analysis with Photon-Counting Detector CT, a Performance Study-A Phantom Study.
Authors: Dillinger D; Department of Vascular and Endovascular Surgery, Federal Armed Services Hospital Koblenz, Koblenz, Germany (D.D.); Department of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (D.D., S.W., D.O.). Electronic address: danieldillinger@bundeswehr.org., Waldeck S; Department of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (D.D., S.W., D.O.); Institute of Neuroradiology, University Medical Centre Johannes Gutenberg University Mainz, Mainz, Germany (S.W.)., Overhoff D; Department of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (D.D., S.W., D.O.); Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Manheim, Germany (D.O.)., Faby S; Department of Computed Tomography, Siemens Healthineers AG, Forchheim, Germany (S.F., M.J., B.S.)., Jürgens M; Department of Computed Tomography, Siemens Healthineers AG, Forchheim, Germany (S.F., M.J., B.S.)., Schmidt B; Department of Computed Tomography, Siemens Healthineers AG, Forchheim, Germany (S.F., M.J., B.S.)., Hesse A; Department of Urology, Urinary Stone Analysis Centre Bonn, Bonn, Germany (A.H.)., Schoch J; Department of Urology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (J.S., H.S., R.S., T.N.)., Schmelz H; Department of Urology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (J.S., H.S., R.S., T.N.)., Stoll R; Department of Urology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (J.S., H.S., R.S., T.N.)., Nestler T; Department of Urology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (J.S., H.S., R.S., T.N.); Department of Urology, University Hospital Cologne, Cologne, Germany (T.N.).
Source: Academic radiology [Acad Radiol] 2025 Apr; Vol. 32 (4), pp. 2005-2012. Date of Electronic Publication: 2024 Nov 15.
Publication Type: Journal Article
Journal Info: Publisher: Association Of University Radiologists Country of Publication: United States NLM ID: 9440159 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1878-4046 (Electronic) Linking ISSN: 10766332 NLM ISO Abbreviation: Acad Radiol Subsets: MEDLINE
Database: MEDLINE Ultimate
FullText Text:
  Availability: 0
Header DbId: mdl
DbLabel: MEDLINE Ultimate
An: 39550346
AccessLevel: 2
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Automated Kidney Stone Composition Analysis with Photon-Counting Detector CT, a Performance Study-A Phantom Study.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AU" term="%22Dillinger+D%22">Dillinger D</searchLink>; Department of Vascular and Endovascular Surgery, Federal Armed Services Hospital Koblenz, Koblenz, Germany (D.D.); Department of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (D.D., S.W., D.O.). Electronic address: danieldillinger@bundeswehr.org.<br /><searchLink fieldCode="AU" term="%22Waldeck+S%22">Waldeck S</searchLink>; Department of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (D.D., S.W., D.O.); Institute of Neuroradiology, University Medical Centre Johannes Gutenberg University Mainz, Mainz, Germany (S.W.).<br /><searchLink fieldCode="AU" term="%22Overhoff+D%22">Overhoff D</searchLink>; Department of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (D.D., S.W., D.O.); Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Manheim, Germany (D.O.).<br /><searchLink fieldCode="AU" term="%22Faby+S%22">Faby S</searchLink>; Department of Computed Tomography, Siemens Healthineers AG, Forchheim, Germany (S.F., M.J., B.S.).<br /><searchLink fieldCode="AU" term="%22Jürgens+M%22">Jürgens M</searchLink>; Department of Computed Tomography, Siemens Healthineers AG, Forchheim, Germany (S.F., M.J., B.S.).<br /><searchLink fieldCode="AU" term="%22Schmidt+B%22">Schmidt B</searchLink>; Department of Computed Tomography, Siemens Healthineers AG, Forchheim, Germany (S.F., M.J., B.S.).<br /><searchLink fieldCode="AU" term="%22Hesse+A%22">Hesse A</searchLink>; Department of Urology, Urinary Stone Analysis Centre Bonn, Bonn, Germany (A.H.).<br /><searchLink fieldCode="AU" term="%22Schoch+J%22">Schoch J</searchLink>; Department of Urology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (J.S., H.S., R.S., T.N.).<br /><searchLink fieldCode="AU" term="%22Schmelz+H%22">Schmelz H</searchLink>; Department of Urology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (J.S., H.S., R.S., T.N.).<br /><searchLink fieldCode="AU" term="%22Stoll+R%22">Stoll R</searchLink>; Department of Urology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (J.S., H.S., R.S., T.N.).<br /><searchLink fieldCode="AU" term="%22Nestler+T%22">Nestler T</searchLink>; Department of Urology, Federal Armed Services Hospital Koblenz, Koblenz, Germany (J.S., H.S., R.S., T.N.); Department of Urology, University Hospital Cologne, Cologne, Germany (T.N.).
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%229440159%22">Academic radiology</searchLink> [Acad Radiol] 2025 Apr; Vol. 32 (4), pp. 2005-2012. <i>Date of Electronic Publication: </i>2024 Nov 15.
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Journal Article
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Association+Of+University+Radiologists%22">Association Of University Radiologists </searchLink><i>Country of Publication: </i>United States <i>NLM ID: </i>9440159 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1878-4046 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2210766332%22">10766332 </searchLink><i>NLM ISO Abbreviation: </i>Acad Radiol <i>Subsets: </i>MEDLINE
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=mdl&AN=39550346
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.acra.2024.10.045
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        StartPage: 2005
    Titles:
      – TitleFull: Automated Kidney Stone Composition Analysis with Photon-Counting Detector CT, a Performance Study-A Phantom Study.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Dillinger D
      – PersonEntity:
          Name:
            NameFull: Waldeck S
      – PersonEntity:
          Name:
            NameFull: Overhoff D
      – PersonEntity:
          Name:
            NameFull: Faby S
      – PersonEntity:
          Name:
            NameFull: Jürgens M
      – PersonEntity:
          Name:
            NameFull: Schmidt B
      – PersonEntity:
          Name:
            NameFull: Hesse A
      – PersonEntity:
          Name:
            NameFull: Schoch J
      – PersonEntity:
          Name:
            NameFull: Schmelz H
      – PersonEntity:
          Name:
            NameFull: Stoll R
      – PersonEntity:
          Name:
            NameFull: Nestler T
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: 2025 Apr
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-electronic
              Value: 1878-4046
          Numbering:
            – Type: volume
              Value: 32
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: Academic radiology
              Type: main
ResultId 1