Closed-Loop Vagus Nerve Stimulation Delivered With a Miniaturized System Produces Lasting Recovery in Individuals With Chronic Stroke.
Saved in:
| Title: | Closed-Loop Vagus Nerve Stimulation Delivered With a Miniaturized System Produces Lasting Recovery in Individuals With Chronic Stroke. |
|---|---|
| Authors: | Hays SA; Department of Bioengineering, Erik Jonsson School of Engineering and Computer Science (S.A.H., E.C.M.), University of Texas at Dallas, Richardson.; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson., Adehunoluwa EA; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson.; Department of Neuroscience, School of Behavioral and Brain Sciences (E.A.A., S.K., Z.S.B., R.L.R., M.P.K.), University of Texas at Dallas, Richardson., Epperson JD; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson., Malley KM; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson., Porter AL; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson., Gallaway HL; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson., Swank C; Baylor Scott & White Research Institute, Dallas, TX (C. Swank, A.J.C.).; Baylor Scott & White Institute for Rehabilitation, Dallas, TX (C. Swank, A.J.C., C. Stevens, J.G., D.A., R.G.H.)., Carrera ÁJ; Baylor Scott & White Research Institute, Dallas, TX (C. Swank, A.J.C.).; Baylor Scott & White Institute for Rehabilitation, Dallas, TX (C. Swank, A.J.C., C. Stevens, J.G., D.A., R.G.H.)., Stevens C; Baylor Scott & White Institute for Rehabilitation, Dallas, TX (C. Swank, A.J.C., C. Stevens, J.G., D.A., R.G.H.)., Gillespie J; Baylor Scott & White Institute for Rehabilitation, Dallas, TX (C. Swank, A.J.C., C. Stevens, J.G., D.A., R.G.H.)., Arnold D; Baylor Scott & White Institute for Rehabilitation, Dallas, TX (C. Swank, A.J.C., C. Stevens, J.G., D.A., R.G.H.)., Kian S; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson.; Department of Neuroscience, School of Behavioral and Brain Sciences (E.A.A., S.K., Z.S.B., R.L.R., M.P.K.), University of Texas at Dallas, Richardson., Bynum ZS; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson.; Department of Neuroscience, School of Behavioral and Brain Sciences (E.A.A., S.K., Z.S.B., R.L.R., M.P.K.), University of Texas at Dallas, Richardson., Meyers EC; Department of Bioengineering, Erik Jonsson School of Engineering and Computer Science (S.A.H., E.C.M.), University of Texas at Dallas, Richardson.; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson., Bleker N; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson., Naftalis RC; Department of Neurosurgery, Baylor University of Medical Center, Dallas, TX (R.C.N.)., Foreman ML; Division of Acute Care Surgery, Baylor Scott & White Health, Dallas, TX (M.L.F.)., Hamilton RG; Baylor Scott & White Institute for Rehabilitation, Dallas, TX (C. Swank, A.J.C., C. Stevens, J.G., D.A., R.G.H.)., Rennaker RL; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson.; Department of Neuroscience, School of Behavioral and Brain Sciences (E.A.A., S.K., Z.S.B., R.L.R., M.P.K.), University of Texas at Dallas, Richardson.; XNerve Medical Inc, Plano, TX (R.L.R.)., Kilgard MP; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson.; Department of Neuroscience, School of Behavioral and Brain Sciences (E.A.A., S.K., Z.S.B., R.L.R., M.P.K.), University of Texas at Dallas, Richardson., Wigginton JG; Texas Biomedical Device Center (S.A.H., E.A.A., J.D.E., K.M.M., A.L.P., H.L.G., S.K., Z.S.B., E.C.M., N.B., R.L.R., M.P.K., J.G.W.), University of Texas at Dallas, Richardson. |
| Source: | Stroke [Stroke] 2026 Jan; Vol. 57 (1), pp. 38-49. Date of Electronic Publication: 2025 Oct 07. |
| Publication Type: | Journal Article; Randomized Controlled Trial |
| Journal Info: | Publisher: Lippincott Williams & Wilkins Country of Publication: United States NLM ID: 0235266 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1524-4628 (Electronic) Linking ISSN: 00392499 NLM ISO Abbreviation: Stroke Subsets: MEDLINE |
| Database: | MEDLINE Ultimate |