Change in composition of blood after passing through circuit of automated device versus manual clinical method for neonatal exchange transfusions.
Saved in:
| Title: | Change in composition of blood after passing through circuit of automated device versus manual clinical method for neonatal exchange transfusions. |
|---|---|
| Authors: | Dutta S; Department of Pediatrics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India. sourabhdutta1@gmail.com., Sharma N; Department of Pediatrics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India., Sachdev S; Department of Transfusion Medicine, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India., Sharma RR; Department of Transfusion Medicine, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India., Verma S; Council of Scientific and Industrial Research-Central Scientific Instruments Organization (CSIR-CSIO), Chandigarh, India., Chatterjee A; Council of Scientific and Industrial Research-Central Scientific Instruments Organization (CSIR-CSIO), Chandigarh, India., Bhatia P; Department of Pediatrics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India., Attri S; Department of Pediatrics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India., Angrup A; Department of Medical Microbiology, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India., Singh S; Council of Scientific and Industrial Research-Central Scientific Instruments Organization (CSIR-CSIO), Chandigarh, India., Singh G; Council of Scientific and Industrial Research-Central Scientific Instruments Organization (CSIR-CSIO), Chandigarh, India., Kumar P; Department of Pediatrics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India. |
| Source: | European journal of pediatrics [Eur J Pediatr] 2025 Dec 22; Vol. 185 (1), pp. 32. Date of Electronic Publication: 2025 Dec 22. |
| Publication Type: | Journal Article; Comparative Study |
| Journal Info: | Publisher: Springer Verlag Country of Publication: Germany NLM ID: 7603873 Publication Model: Electronic Cited Medium: Internet ISSN: 1432-1076 (Electronic) Linking ISSN: 03406199 NLM ISO Abbreviation: Eur J Pediatr Subsets: MEDLINE |
| Database: | MEDLINE Ultimate |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: mdl DbLabel: MEDLINE Ultimate An: 41428230 AccessLevel: 2 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Change in composition of blood after passing through circuit of automated device versus manual clinical method for neonatal exchange transfusions. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Dutta+S%22">Dutta S</searchLink>; Department of Pediatrics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India. sourabhdutta1@gmail.com.<br /><searchLink fieldCode="AU" term="%22Sharma+N%22">Sharma N</searchLink>; Department of Pediatrics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.<br /><searchLink fieldCode="AU" term="%22Sachdev+S%22">Sachdev S</searchLink>; Department of Transfusion Medicine, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.<br /><searchLink fieldCode="AU" term="%22Sharma+RR%22">Sharma RR</searchLink>; Department of Transfusion Medicine, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.<br /><searchLink fieldCode="AU" term="%22Verma+S%22">Verma S</searchLink>; Council of Scientific and Industrial Research-Central Scientific Instruments Organization (CSIR-CSIO), Chandigarh, India.<br /><searchLink fieldCode="AU" term="%22Chatterjee+A%22">Chatterjee A</searchLink>; Council of Scientific and Industrial Research-Central Scientific Instruments Organization (CSIR-CSIO), Chandigarh, India.<br /><searchLink fieldCode="AU" term="%22Bhatia+P%22">Bhatia P</searchLink>; Department of Pediatrics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.<br /><searchLink fieldCode="AU" term="%22Attri+S%22">Attri S</searchLink>; Department of Pediatrics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.<br /><searchLink fieldCode="AU" term="%22Angrup+A%22">Angrup A</searchLink>; Department of Medical Microbiology, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.<br /><searchLink fieldCode="AU" term="%22Singh+S%22">Singh S</searchLink>; Council of Scientific and Industrial Research-Central Scientific Instruments Organization (CSIR-CSIO), Chandigarh, India.<br /><searchLink fieldCode="AU" term="%22Singh+G%22">Singh G</searchLink>; Council of Scientific and Industrial Research-Central Scientific Instruments Organization (CSIR-CSIO), Chandigarh, India.<br /><searchLink fieldCode="AU" term="%22Kumar+P%22">Kumar P</searchLink>; Department of Pediatrics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%227603873%22">European journal of pediatrics</searchLink> [Eur J Pediatr] 2025 Dec 22; Vol. 185 (1), pp. 32. <i>Date of Electronic Publication: </i>2025 Dec 22. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article; Comparative Study – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Springer+Verlag%22">Springer Verlag </searchLink><i>Country of Publication: </i>Germany <i>NLM ID: </i>7603873 <i>Publication Model: </i>Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1432-1076 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2203406199%22">03406199 </searchLink><i>NLM ISO Abbreviation: </i>Eur J Pediatr <i>Subsets: </i>MEDLINE |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=mdl&AN=41428230 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s00431-025-06676-7 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 32 Titles: – TitleFull: Change in composition of blood after passing through circuit of automated device versus manual clinical method for neonatal exchange transfusions. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Dutta S – PersonEntity: Name: NameFull: Sharma N – PersonEntity: Name: NameFull: Sachdev S – PersonEntity: Name: NameFull: Sharma RR – PersonEntity: Name: NameFull: Verma S – PersonEntity: Name: NameFull: Chatterjee A – PersonEntity: Name: NameFull: Bhatia P – PersonEntity: Name: NameFull: Attri S – PersonEntity: Name: NameFull: Angrup A – PersonEntity: Name: NameFull: Singh S – PersonEntity: Name: NameFull: Singh G – PersonEntity: Name: NameFull: Kumar P IsPartOfRelationships: – BibEntity: Dates: – D: 22 M: 12 Text: 2025 Dec 22 Type: published Y: 2025 Identifiers: – Type: issn-electronic Value: 1432-1076 Numbering: – Type: volume Value: 185 – Type: issue Value: 1 Titles: – TitleFull: European journal of pediatrics Type: main |
| ResultId | 1 |