Clinometric properties of a clinical spasticity measurement tool.

Saved in:
Bibliographic Details
Title: Clinometric properties of a clinical spasticity measurement tool.
Authors: Voerman GE (AUTHOR), Burridge JH (AUTHOR), Hitchcock RA (AUTHOR), Hermens HJ (AUTHOR)
Source: Disability & Rehabilitation. Dec2007, Vol. 29 Issue 24, p1870-1880. 11p.
Abstract: Purpose. To investigate clinometric properties of an Anglo-Dutch spasticity measurement tool (ADSMT), an objective tool providing information about both neurophysiological and biomechanical aspects of spasticity about the wrist joint in the clinical setting. Method. ADSMT measurements were performed with 12 healthy and 11 participants with post-stroke spasticity, and consisted of assessing the maximum range of passive wrist movement (pROM) and passive wrist extension at different cycle rates. Outcome measures were wrist angle, flexor and extensor activation, and resistance to movement. Intra-class Correlation Coefficients (ICCs) were calculated for inter-rater and test-retest reliability. Validity was investigated by calculating Spearman's rho between ADSMT outcome measures and the Modified Ashworth Scale (n = 12), the Action Research Arm Test (n = 6), and a validated wrist rig (n = 6). Results. Impaired participants had higher flexor activity and higher resistance to movement during passive wrist extension compared to unimpaired participants. For all outcome measures inter-rater and test-retest reliability were satisfactory to good and concurrent validity was sufficient. Conclusions. Outcome measures related to wrist flexor activity and resistance to movement during extension are promising for spasticity assessment using the ADSMT. Further knowledge on reference values and practicality is necessary for this tool to become incorporated in the clinical setting. [ABSTRACT FROM AUTHOR]
Copyright of Disability & Rehabilitation is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Psychology and Behavioral Sciences Collection
Description
Abstract:Purpose. To investigate clinometric properties of an Anglo-Dutch spasticity measurement tool (ADSMT), an objective tool providing information about both neurophysiological and biomechanical aspects of spasticity about the wrist joint in the clinical setting. Method. ADSMT measurements were performed with 12 healthy and 11 participants with post-stroke spasticity, and consisted of assessing the maximum range of passive wrist movement (pROM) and passive wrist extension at different cycle rates. Outcome measures were wrist angle, flexor and extensor activation, and resistance to movement. Intra-class Correlation Coefficients (ICCs) were calculated for inter-rater and test-retest reliability. Validity was investigated by calculating Spearman's rho between ADSMT outcome measures and the Modified Ashworth Scale (n = 12), the Action Research Arm Test (n = 6), and a validated wrist rig (n = 6). Results. Impaired participants had higher flexor activity and higher resistance to movement during passive wrist extension compared to unimpaired participants. For all outcome measures inter-rater and test-retest reliability were satisfactory to good and concurrent validity was sufficient. Conclusions. Outcome measures related to wrist flexor activity and resistance to movement during extension are promising for spasticity assessment using the ADSMT. Further knowledge on reference values and practicality is necessary for this tool to become incorporated in the clinical setting. [ABSTRACT FROM AUTHOR]
ISSN:09638288
DOI:10.1080/09638280601143752