Physiological responses to multiple speed treadmill walking for Syme vs. transtibial amputation -- a case report.
Saved in:
| Title: | Physiological responses to multiple speed treadmill walking for Syme vs. transtibial amputation -- a case report. |
|---|---|
| Authors: | Lin-Chan S (AUTHOR), Nielsen DH (AUTHOR), Shurr DG (AUTHOR), Saltzman CL (AUTHOR) |
| Source: | Disability & Rehabilitation. 12/2/2003, Vol. 25 Issue 23, p1333-1338. 6p. |
| Abstract: | PURPOSE: To date, there have been no longitudinal studies comparing walking at different levels of amputation. The objective of this study was to compare the self-selected walking velocity (SSWV) and selected physiologic variables during walking between a Syme and a later transtibial level of amputation for a single subject. Additional comparison was made between the SACH foot prosthesis and a dynamic response foot prosthesis. METHOD: A 35-year-old male with a traumatic Syme amputation later underwent elective transtibial amputation. SSWV and multiple speed treadmill walking tests (53.64, 67.05, 80.46, 93.87 and 107.28 m/min) were evaluated under three conditions (Syme prosthesis with SACH foot, transtibial prosthesis with SACH foot, and transtibial prosthesis with Flex-Foot). RESULTS: Walking with transtibial prosthesis showed minimal differences in oxygen consumption (0 - 5% reduction), heart rate response (0 - 1% reduction), or gait efficiency (0 - 5% improvement) across all speeds when compared with Syme prosthesis (both with SACH foot). However, the SSWV was 6 - 8% faster for the transtibial SACH foot. Walking with transtibial Flex-Foot required less cardiovascular demand than with transtibial SACH foot at higher speeds. CONCLUSIONS: In this case report, it seemed that transtibial amputation did not have adverse effects on selected physiological responses at a variety of walking speeds when compared to Syme amputation, and that the use of a dynamic response foot enhanced his gait performance. Further experimental studies involving more subjects with traumatic Syme and transtibial amputations are required to better understand the effect of these two levels of amputation on energy cost of walking. [ABSTRACT FROM AUTHOR] |
| Copyright of Disability & Rehabilitation is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Psychology and Behavioral Sciences Collection |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: pbh DbLabel: Psychology and Behavioral Sciences Collection An: 106743108 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Physiological responses to multiple speed treadmill walking for Syme vs. transtibial amputation -- a case report. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Lin-Chan+S%22">Lin-Chan S</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nielsen+DH%22">Nielsen DH</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Shurr+DG%22">Shurr DG</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Saltzman+CL%22">Saltzman CL</searchLink> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Disability+%26+Rehabilitation%22">Disability & Rehabilitation</searchLink>. 12/2/2003, Vol. 25 Issue 23, p1333-1338. 6p. – Name: Abstract Label: Abstract Group: Ab Data: PURPOSE: To date, there have been no longitudinal studies comparing walking at different levels of amputation. The objective of this study was to compare the self-selected walking velocity (SSWV) and selected physiologic variables during walking between a Syme and a later transtibial level of amputation for a single subject. Additional comparison was made between the SACH foot prosthesis and a dynamic response foot prosthesis. METHOD: A 35-year-old male with a traumatic Syme amputation later underwent elective transtibial amputation. SSWV and multiple speed treadmill walking tests (53.64, 67.05, 80.46, 93.87 and 107.28 m/min) were evaluated under three conditions (Syme prosthesis with SACH foot, transtibial prosthesis with SACH foot, and transtibial prosthesis with Flex-Foot). RESULTS: Walking with transtibial prosthesis showed minimal differences in oxygen consumption (0 - 5% reduction), heart rate response (0 - 1% reduction), or gait efficiency (0 - 5% improvement) across all speeds when compared with Syme prosthesis (both with SACH foot). However, the SSWV was 6 - 8% faster for the transtibial SACH foot. Walking with transtibial Flex-Foot required less cardiovascular demand than with transtibial SACH foot at higher speeds. CONCLUSIONS: In this case report, it seemed that transtibial amputation did not have adverse effects on selected physiological responses at a variety of walking speeds when compared to Syme amputation, and that the use of a dynamic response foot enhanced his gait performance. Further experimental studies involving more subjects with traumatic Syme and transtibial amputations are required to better understand the effect of these two levels of amputation on energy cost of walking. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Disability & Rehabilitation is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=pbh&AN=106743108 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1080/09638280310001608618 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 6 StartPage: 1333 Titles: – TitleFull: Physiological responses to multiple speed treadmill walking for Syme vs. transtibial amputation -- a case report. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Lin-Chan S – PersonEntity: Name: NameFull: Nielsen DH – PersonEntity: Name: NameFull: Shurr DG – PersonEntity: Name: NameFull: Saltzman CL IsPartOfRelationships: – BibEntity: Dates: – D: 02 M: 12 Text: 12/2/2003 Type: published Y: 2003 Identifiers: – Type: issn-print Value: 09638288 Numbering: – Type: volume Value: 25 – Type: issue Value: 23 Titles: – TitleFull: Disability & Rehabilitation Type: main |
| ResultId | 1 |