Stimulus characteristics of a novel air‐based multiple stimulus aesthesiometer.
Saved in:
| Title: | Stimulus characteristics of a novel air‐based multiple stimulus aesthesiometer. |
|---|---|
| Authors: | Mungalsingh, Melanie A. (AUTHOR), Thompson, Benjamin (AUTHOR), Peterson, Sean D. (AUTHOR), Murphy, Paul J. (AUTHOR) |
| Source: | Ophthalmic & Physiological Optics. Jan2024, Vol. 44 Issue 1, p32-41. 10p. |
| Abstract: | Purpose: To identify the stimulus airflow characteristics and confirm the consistency of a novel air jet‐based aesthesiometer capable of producing and applying multiple stimuli separated either by time and/or by space. Methods: A novel aesthesiometer (Dolphin Aesthesiometer) was designed around a micro‐blower under software management. Two nozzle attachments assisted in airflow control (flexible tube 1.6 mm diameter; brass tube 0.5 mm diameter). Four studies that tested the characteristics of the airflow and stimulus consistency were completed: (i) airflow pattern/trajectory, (ii) airflow surface dispersion, (iii) force of airflow across a range of stimulus strengths and (iv) thermal effects on the ocular surface. Results: Stimulus characteristic studies revealed: (i) airflow is coherent within the expected test distance range for the instrument, and spread rate is constant irrespective of stimulus strength; (ii) airflow dispersion occurs upon encountering a surface and dispersion increases with increasing airflow rate; (iii) a consistent and small force (10−4 N) is applied by the airflow and (iv) repeatable thermal effects occur in relation to the airflow, and the mode of stimulation of the Dolphin aesthesiometer is predominantly thermal in nature. Conclusions: These studies confirm the repeatability and consistency of the novel instrument. The device is suitable for measuring corneal sensitivity. The availability of additional air jets allows the application of multiple stimuli to facilitate corneal summation investigations. [ABSTRACT FROM AUTHOR] |
| Copyright of Ophthalmic & Physiological Optics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Psychology and Behavioral Sciences Collection |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: pbh DbLabel: Psychology and Behavioral Sciences Collection An: 174109233 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Stimulus characteristics of a novel air‐based multiple stimulus aesthesiometer. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Mungalsingh%2C+Melanie+A%2E%22">Mungalsingh, Melanie A.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Thompson%2C+Benjamin%22">Thompson, Benjamin</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Peterson%2C+Sean+D%2E%22">Peterson, Sean D.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Murphy%2C+Paul+J%2E%22">Murphy, Paul J.</searchLink> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Ophthalmic+%26+Physiological+Optics%22">Ophthalmic & Physiological Optics</searchLink>. Jan2024, Vol. 44 Issue 1, p32-41. 10p. – Name: Abstract Label: Abstract Group: Ab Data: Purpose: To identify the stimulus airflow characteristics and confirm the consistency of a novel air jet‐based aesthesiometer capable of producing and applying multiple stimuli separated either by time and/or by space. Methods: A novel aesthesiometer (Dolphin Aesthesiometer) was designed around a micro‐blower under software management. Two nozzle attachments assisted in airflow control (flexible tube 1.6 mm diameter; brass tube 0.5 mm diameter). Four studies that tested the characteristics of the airflow and stimulus consistency were completed: (i) airflow pattern/trajectory, (ii) airflow surface dispersion, (iii) force of airflow across a range of stimulus strengths and (iv) thermal effects on the ocular surface. Results: Stimulus characteristic studies revealed: (i) airflow is coherent within the expected test distance range for the instrument, and spread rate is constant irrespective of stimulus strength; (ii) airflow dispersion occurs upon encountering a surface and dispersion increases with increasing airflow rate; (iii) a consistent and small force (10−4 N) is applied by the airflow and (iv) repeatable thermal effects occur in relation to the airflow, and the mode of stimulation of the Dolphin aesthesiometer is predominantly thermal in nature. Conclusions: These studies confirm the repeatability and consistency of the novel instrument. The device is suitable for measuring corneal sensitivity. The availability of additional air jets allows the application of multiple stimuli to facilitate corneal summation investigations. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Ophthalmic & Physiological Optics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=pbh&AN=174109233 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1111/opo.13252 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 32 Titles: – TitleFull: Stimulus characteristics of a novel air‐based multiple stimulus aesthesiometer. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Mungalsingh, Melanie A. – PersonEntity: Name: NameFull: Thompson, Benjamin – PersonEntity: Name: NameFull: Peterson, Sean D. – PersonEntity: Name: NameFull: Murphy, Paul J. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Text: Jan2024 Type: published Y: 2024 Identifiers: – Type: issn-print Value: 02755408 Numbering: – Type: volume Value: 44 – Type: issue Value: 1 Titles: – TitleFull: Ophthalmic & Physiological Optics Type: main |
| ResultId | 1 |