Tablet‐based tests of everyday visual function in a diabetic macular oedema (DME) clinic waiting area: A feasibility study.
Saved in:
| Title: | Tablet‐based tests of everyday visual function in a diabetic macular oedema (DME) clinic waiting area: A feasibility study. |
|---|---|
| Authors: | Taylor, Deanna J. (AUTHOR), Alquiza, Paolo J. (AUTHOR), Jones, Pete R. (AUTHOR), Wilson, Iain (AUTHOR), Bi, Wei (AUTHOR), Sim, Dawn A. (AUTHOR), Crabb, David P. (AUTHOR) |
| Source: | Ophthalmic & Physiological Optics. Mar2024, Vol. 44 Issue 2, p388-398. 11p. |
| Abstract: | Purpose: (1) To assess the feasibility of conducting tablet‐based vision tests in hospital clinic waiting areas; (2) To test the hypothesis that increasing severity of diabetic macular oedema (DME) is associated with the performance of tablet‐based surrogates of everyday tasks and self‐reported visual function. Methods: Sixty‐one people with mild (n = 28), moderate (n = 24) or severe (n = 9) DME performed two tablet‐based tests of 'real‐world' visual function (visual search and face recognition) while waiting for appointments in a hospital outpatient clinic. Participants also completed a tablet‐based version of a seven‐item, visual‐functioning (VF‐7) patient‐reported outcome measure. Test performance was compared to previously published 99% normative limits for normally sighted individuals. Results: Thirty‐four participants (56%; 95% confidence interval [CI] 43%–68%) exceeded normative limits for visual search, while eight (13%; 95% CI 65%–24%) exceeded normative limits for face discrimination. Search duration was significantly longer for people with severe DME than those with mild and moderate DME (p = 0.01). Face discrimination performance was not significantly associated with DME severity. VF‐7 scores were statistically similar across DME severity groups. Median time to complete all elements (eligibility screening, both tablet‐based tasks and the VF‐7) was 22 (quartiles 19, 25) min. Further, 98% and 87% of participants, respectively, reported the search task and face discrimination task to be enjoyable, while 25% and 97%, respectively, reported finding the two tasks to be difficult. Conclusions: Portable tablet‐based tests are quick, acceptable to patients and feasible to be performed in a clinic waiting area with minimal supervision. They have the potential to be piloted in patients' homes for self‐monitoring. [ABSTRACT FROM AUTHOR] |
| Copyright of Ophthalmic & Physiological Optics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Psychology and Behavioral Sciences Collection |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: pbh DbLabel: Psychology and Behavioral Sciences Collection An: 175305038 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Tablet‐based tests of everyday visual function in a diabetic macular oedema (DME) clinic waiting area: A feasibility study. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Taylor%2C+Deanna+J%2E%22">Taylor, Deanna J.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Alquiza%2C+Paolo+J%2E%22">Alquiza, Paolo J.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Jones%2C+Pete+R%2E%22">Jones, Pete R.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wilson%2C+Iain%22">Wilson, Iain</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bi%2C+Wei%22">Bi, Wei</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sim%2C+Dawn+A%2E%22">Sim, Dawn A.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Crabb%2C+David+P%2E%22">Crabb, David P.</searchLink> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Ophthalmic+%26+Physiological+Optics%22">Ophthalmic & Physiological Optics</searchLink>. Mar2024, Vol. 44 Issue 2, p388-398. 11p. – Name: Abstract Label: Abstract Group: Ab Data: Purpose: (1) To assess the feasibility of conducting tablet‐based vision tests in hospital clinic waiting areas; (2) To test the hypothesis that increasing severity of diabetic macular oedema (DME) is associated with the performance of tablet‐based surrogates of everyday tasks and self‐reported visual function. Methods: Sixty‐one people with mild (n = 28), moderate (n = 24) or severe (n = 9) DME performed two tablet‐based tests of 'real‐world' visual function (visual search and face recognition) while waiting for appointments in a hospital outpatient clinic. Participants also completed a tablet‐based version of a seven‐item, visual‐functioning (VF‐7) patient‐reported outcome measure. Test performance was compared to previously published 99% normative limits for normally sighted individuals. Results: Thirty‐four participants (56%; 95% confidence interval [CI] 43%–68%) exceeded normative limits for visual search, while eight (13%; 95% CI 65%–24%) exceeded normative limits for face discrimination. Search duration was significantly longer for people with severe DME than those with mild and moderate DME (p = 0.01). Face discrimination performance was not significantly associated with DME severity. VF‐7 scores were statistically similar across DME severity groups. Median time to complete all elements (eligibility screening, both tablet‐based tasks and the VF‐7) was 22 (quartiles 19, 25) min. Further, 98% and 87% of participants, respectively, reported the search task and face discrimination task to be enjoyable, while 25% and 97%, respectively, reported finding the two tasks to be difficult. Conclusions: Portable tablet‐based tests are quick, acceptable to patients and feasible to be performed in a clinic waiting area with minimal supervision. They have the potential to be piloted in patients' homes for self‐monitoring. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Ophthalmic & Physiological Optics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=pbh&AN=175305038 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1111/opo.13261 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 11 StartPage: 388 Titles: – TitleFull: Tablet‐based tests of everyday visual function in a diabetic macular oedema (DME) clinic waiting area: A feasibility study. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Taylor, Deanna J. – PersonEntity: Name: NameFull: Alquiza, Paolo J. – PersonEntity: Name: NameFull: Jones, Pete R. – PersonEntity: Name: NameFull: Wilson, Iain – PersonEntity: Name: NameFull: Bi, Wei – PersonEntity: Name: NameFull: Sim, Dawn A. – PersonEntity: Name: NameFull: Crabb, David P. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 03 Text: Mar2024 Type: published Y: 2024 Identifiers: – Type: issn-print Value: 02755408 Numbering: – Type: volume Value: 44 – Type: issue Value: 2 Titles: – TitleFull: Ophthalmic & Physiological Optics Type: main |
| ResultId | 1 |