Changes in the BOLD signal of S1 and BA3 per finger/phalanx as a response to high-frequency vibratory stimulation.

Saved in:
Bibliographic Details
Title: Changes in the BOLD signal of S1 and BA3 per finger/phalanx as a response to high-frequency vibratory stimulation.
Authors: Choi, Mi-Hyun (AUTHOR), Kim, Kyu-Beom (AUTHOR), Kim, Ye-Jin (AUTHOR), Kim, Ji-Su (AUTHOR), Kim, Hyung-Sik (AUTHOR), Yi, Jeong-Han (AUTHOR), Chung, Soon-Cheol (AUTHOR)
Source: Somatosensory & Motor Research. Mar2024, Vol. 41 Issue 1, p48-55. 8p.
Subjects: Thumb, Somatosensory cortex, Fingers, Oxygen in the blood, Functional magnetic resonance imaging
Abstract: The purpose of this study was to determine the changes in the Blood Oxygen Level Dependent signal of Primary somatosensory area (S1) and Brodmann area 3 (BA3) per finger and phalanx in comparison to the activation voxel when 250 Hz vibratory stimulation with high sensitivity for the Pacinian corpuscle was given to the four fingers and three phalanges. The result of analyzing the activation voxel showed a significant difference for S1 per finger and phalanx, but for BA3, no significant difference was observed despite a similar trend to S1. In contrast, the activation intensity (BOLD) displayed a significant difference for S1 per finger and phalanx and for BA3, where the activation voxel had no significant variation. In addition, while the result of S1 did not indicate whether the index or the little fingers had the highest sensitivity based on the BOLD signal per finger, the result of BA3 marked the strongest BOLD signal for the little finger as a response to 250 Hz vibratory stimulation. The activation intensity per phalanx was the highest for the intermediate phalanx for S1 and BA3, which was in line with a previous study comparing the activation voxel. The method based on the intensity of the nerve activation is presumed to have high sensitivity as the signal intensity is monitored within a specific, defined area. Thus, for the extraction of brain activation patterns of micro-domains, such as BA3, monitoring the BOLD signal that reflects the nerve activation intensity more sensitively is likely to be advantageous. [ABSTRACT FROM AUTHOR]
Copyright of Somatosensory & Motor Research is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Psychology and Behavioral Sciences Collection
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: pbh
DbLabel: Psychology and Behavioral Sciences Collection
An: 175722568
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Changes in the BOLD signal of S1 and BA3 per finger/phalanx as a response to high-frequency vibratory stimulation.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Choi%2C+Mi-Hyun%22">Choi, Mi-Hyun</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kim%2C+Kyu-Beom%22">Kim, Kyu-Beom</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kim%2C+Ye-Jin%22">Kim, Ye-Jin</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kim%2C+Ji-Su%22">Kim, Ji-Su</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kim%2C+Hyung-Sik%22">Kim, Hyung-Sik</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Yi%2C+Jeong-Han%22">Yi, Jeong-Han</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Chung%2C+Soon-Cheol%22">Chung, Soon-Cheol</searchLink> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Somatosensory+%26+Motor+Research%22">Somatosensory & Motor Research</searchLink>. Mar2024, Vol. 41 Issue 1, p48-55. 8p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Thumb%22">Thumb</searchLink><br /><searchLink fieldCode="DE" term="%22Somatosensory+cortex%22">Somatosensory cortex</searchLink><br /><searchLink fieldCode="DE" term="%22Fingers%22">Fingers</searchLink><br /><searchLink fieldCode="DE" term="%22Oxygen+in+the+blood%22">Oxygen in the blood</searchLink><br /><searchLink fieldCode="DE" term="%22Functional+magnetic+resonance+imaging%22">Functional magnetic resonance imaging</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The purpose of this study was to determine the changes in the Blood Oxygen Level Dependent signal of Primary somatosensory area (S1) and Brodmann area 3 (BA3) per finger and phalanx in comparison to the activation voxel when 250 Hz vibratory stimulation with high sensitivity for the Pacinian corpuscle was given to the four fingers and three phalanges. The result of analyzing the activation voxel showed a significant difference for S1 per finger and phalanx, but for BA3, no significant difference was observed despite a similar trend to S1. In contrast, the activation intensity (BOLD) displayed a significant difference for S1 per finger and phalanx and for BA3, where the activation voxel had no significant variation. In addition, while the result of S1 did not indicate whether the index or the little fingers had the highest sensitivity based on the BOLD signal per finger, the result of BA3 marked the strongest BOLD signal for the little finger as a response to 250 Hz vibratory stimulation. The activation intensity per phalanx was the highest for the intermediate phalanx for S1 and BA3, which was in line with a previous study comparing the activation voxel. The method based on the intensity of the nerve activation is presumed to have high sensitivity as the signal intensity is monitored within a specific, defined area. Thus, for the extraction of brain activation patterns of micro-domains, such as BA3, monitoring the BOLD signal that reflects the nerve activation intensity more sensitively is likely to be advantageous. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Somatosensory & Motor Research is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=pbh&AN=175722568
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1080/08990220.2023.2173165
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 48
    Subjects:
      – SubjectFull: Thumb
        Type: general
      – SubjectFull: Somatosensory cortex
        Type: general
      – SubjectFull: Fingers
        Type: general
      – SubjectFull: Oxygen in the blood
        Type: general
      – SubjectFull: Functional magnetic resonance imaging
        Type: general
    Titles:
      – TitleFull: Changes in the BOLD signal of S1 and BA3 per finger/phalanx as a response to high-frequency vibratory stimulation.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Choi, Mi-Hyun
      – PersonEntity:
          Name:
            NameFull: Kim, Kyu-Beom
      – PersonEntity:
          Name:
            NameFull: Kim, Ye-Jin
      – PersonEntity:
          Name:
            NameFull: Kim, Ji-Su
      – PersonEntity:
          Name:
            NameFull: Kim, Hyung-Sik
      – PersonEntity:
          Name:
            NameFull: Yi, Jeong-Han
      – PersonEntity:
          Name:
            NameFull: Chung, Soon-Cheol
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: Mar2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 08990220
          Numbering:
            – Type: volume
              Value: 41
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Somatosensory & Motor Research
              Type: main
ResultId 1