Tinnitus pitch does not always fall within the frequency range of hearing loss – a cross-sectional study on the mechanism of tinnitus production.

Saved in:
Bibliographic Details
Title: Tinnitus pitch does not always fall within the frequency range of hearing loss – a cross-sectional study on the mechanism of tinnitus production.
Authors: Liu, Yuehong (AUTHOR), Hu, Jiahua (AUTHOR), Yang, Siyi (AUTHOR), Xie, Hongbo (AUTHOR), Wang, Yulu (AUTHOR), Ni, Tianyi (AUTHOR), Han, Zhao (AUTHOR)
Source: Acta Oto-Laryngologica. Mar2024, Vol. 144 Issue 3, p226-232. 7p.
Subjects: Cross-sectional method, Audiometry, Descriptive statistics, Tinnitus, Hearing disorders, Hearing levels, Impedance audiometry, Disease complications
Abstract (English): Clinically, we find that tinnitus patients often have hearing loss. According to the most accepted mechanism of tinnitus, that is, the spontaneous discharge and abnormal synchronization of neurons after afferent reduction, tinnitus frequency is closely related to the frequency of hearing loss. The purpose of this study was to investigate the correlation of tinnitus pitch with the frequency of hearing loss. A total of 500 patients with unilateral or bilateral chronic tinnitus were enrolled in this study. All patients underwent pure tone audiometry (PTA) and tinnitus acoustic examination. Hearing loss levels and frequencies were recorded. The relationship between tinnitus pitch and hearing loss level and frequency was statistically analyzed. Our results showed that 96.6% of the 500 tinnitus patients had hearing loss. Statistical analysis showed that low frequency (LF) tinnitus was correlated with LF hearing loss, but moderate frequency & high frequency (MF&HF) tinnitus was not significantly associated with MF&HF hearing loss. The coincidence of tinnitus pitch with the highest hearing threshold correlated with the degree of hearing loss. The vast majority of patients with chronic subjective tinnitus had hearing loss, and the frequency of tinnitus correlated with the degree and frequency of hearing loss but not exactly fall within the frequency range of hearing loss. [ABSTRACT FROM AUTHOR]
Abstract (Chinese): 临床上发现耳鸣患者常伴有听力损失。根据最为普遍接受的耳鸣机制, 即传入神经减少后神经元的自发放电和异常同步, 耳鸣频率与听力损失频率密切相关。 本研究旨在探讨耳鸣音高与听力损失频率的相关性。 本研究共纳入500例单侧或双侧慢性耳鸣患者。所有患者均接受纯音测听(PTA)检查和耳鸣声学检查。记录听力损失程度和频率。统计分析耳鸣音高与听力损失程度和频率之间的关系。 我们的研究结果显示, 500例耳鸣患者中有96.6%患有听力损失。统计分析显示, LF耳鸣与LF听力损失相关, 而MF&HF耳鸣与MF&HF听力损失无明显相关性, 耳鸣音高与最高听力阈值的吻合与听力损失程度相关。 绝大多数慢性主观性耳鸣患者都伴有听力损失, 耳鸣频率与听力损失程度及频率相关, 但并不完全在听力损失的频率范围内。 [ABSTRACT FROM AUTHOR]
Copyright of Acta Oto-Laryngologica is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Psychology and Behavioral Sciences Collection
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: pbh
DbLabel: Psychology and Behavioral Sciences Collection
An: 177943202
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Tinnitus pitch does not always fall within the frequency range of hearing loss – a cross-sectional study on the mechanism of tinnitus production.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Liu%2C+Yuehong%22">Liu, Yuehong</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hu%2C+Jiahua%22">Hu, Jiahua</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Yang%2C+Siyi%22">Yang, Siyi</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Xie%2C+Hongbo%22">Xie, Hongbo</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wang%2C+Yulu%22">Wang, Yulu</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ni%2C+Tianyi%22">Ni, Tianyi</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Han%2C+Zhao%22">Han, Zhao</searchLink> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Acta+Oto-Laryngologica%22">Acta Oto-Laryngologica</searchLink>. Mar2024, Vol. 144 Issue 3, p226-232. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Cross-sectional+method%22">Cross-sectional method</searchLink><br /><searchLink fieldCode="DE" term="%22Audiometry%22">Audiometry</searchLink><br /><searchLink fieldCode="DE" term="%22Descriptive+statistics%22">Descriptive statistics</searchLink><br /><searchLink fieldCode="DE" term="%22Tinnitus%22">Tinnitus</searchLink><br /><searchLink fieldCode="DE" term="%22Hearing+disorders%22">Hearing disorders</searchLink><br /><searchLink fieldCode="DE" term="%22Hearing+levels%22">Hearing levels</searchLink><br /><searchLink fieldCode="DE" term="%22Impedance+audiometry%22">Impedance audiometry</searchLink><br /><searchLink fieldCode="DE" term="%22Disease+complications%22">Disease complications</searchLink>
– Name: Abstract
  Label: Abstract (English)
  Group: Ab
  Data: Clinically, we find that tinnitus patients often have hearing loss. According to the most accepted mechanism of tinnitus, that is, the spontaneous discharge and abnormal synchronization of neurons after afferent reduction, tinnitus frequency is closely related to the frequency of hearing loss. The purpose of this study was to investigate the correlation of tinnitus pitch with the frequency of hearing loss. A total of 500 patients with unilateral or bilateral chronic tinnitus were enrolled in this study. All patients underwent pure tone audiometry (PTA) and tinnitus acoustic examination. Hearing loss levels and frequencies were recorded. The relationship between tinnitus pitch and hearing loss level and frequency was statistically analyzed. Our results showed that 96.6% of the 500 tinnitus patients had hearing loss. Statistical analysis showed that low frequency (LF) tinnitus was correlated with LF hearing loss, but moderate frequency & high frequency (MF&HF) tinnitus was not significantly associated with MF&HF hearing loss. The coincidence of tinnitus pitch with the highest hearing threshold correlated with the degree of hearing loss. The vast majority of patients with chronic subjective tinnitus had hearing loss, and the frequency of tinnitus correlated with the degree and frequency of hearing loss but not exactly fall within the frequency range of hearing loss. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label: Abstract (Chinese)
  Group: Ab
  Data: 临床上发现耳鸣患者常伴有听力损失。根据最为普遍接受的耳鸣机制, 即传入神经减少后神经元的自发放电和异常同步, 耳鸣频率与听力损失频率密切相关。 本研究旨在探讨耳鸣音高与听力损失频率的相关性。 本研究共纳入500例单侧或双侧慢性耳鸣患者。所有患者均接受纯音测听(PTA)检查和耳鸣声学检查。记录听力损失程度和频率。统计分析耳鸣音高与听力损失程度和频率之间的关系。 我们的研究结果显示, 500例耳鸣患者中有96.6%患有听力损失。统计分析显示, LF耳鸣与LF听力损失相关, 而MF&HF耳鸣与MF&HF听力损失无明显相关性, 耳鸣音高与最高听力阈值的吻合与听力损失程度相关。 绝大多数慢性主观性耳鸣患者都伴有听力损失, 耳鸣频率与听力损失程度及频率相关, 但并不完全在听力损失的频率范围内。 [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Acta Oto-Laryngologica is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=pbh&AN=177943202
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1080/00016489.2024.2355227
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 226
    Subjects:
      – SubjectFull: Cross-sectional method
        Type: general
      – SubjectFull: Audiometry
        Type: general
      – SubjectFull: Descriptive statistics
        Type: general
      – SubjectFull: Tinnitus
        Type: general
      – SubjectFull: Hearing disorders
        Type: general
      – SubjectFull: Hearing levels
        Type: general
      – SubjectFull: Impedance audiometry
        Type: general
      – SubjectFull: Disease complications
        Type: general
    Titles:
      – TitleFull: Tinnitus pitch does not always fall within the frequency range of hearing loss – a cross-sectional study on the mechanism of tinnitus production.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Liu, Yuehong
      – PersonEntity:
          Name:
            NameFull: Hu, Jiahua
      – PersonEntity:
          Name:
            NameFull: Yang, Siyi
      – PersonEntity:
          Name:
            NameFull: Xie, Hongbo
      – PersonEntity:
          Name:
            NameFull: Wang, Yulu
      – PersonEntity:
          Name:
            NameFull: Ni, Tianyi
      – PersonEntity:
          Name:
            NameFull: Han, Zhao
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: Mar2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 00016489
          Numbering:
            – Type: volume
              Value: 144
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Acta Oto-Laryngologica
              Type: main
ResultId 1