Can we really distinguish 'responders' from 'non‐responders' to myopia control interventions?

Saved in:
Bibliographic Details
Title: Can we really distinguish 'responders' from 'non‐responders' to myopia control interventions?
Authors: Brennan, Noel A. (AUTHOR), Nixon, Alex D. (AUTHOR), Cheng, Xu (AUTHOR), Bullimore, Mark A. (AUTHOR)
Source: Ophthalmic & Physiological Optics. Nov2024, Vol. 44 Issue 7, p1363-1367. 5p.
Subjects: Myopia, Atropine, Age groups, Sample size (Statistics), Lamps
Abstract: Purpose: It is common to hear talk of 'responders' and 'non‐responders' with respect to myopia control interventions. We consider the reality of distinguishing these sub‐groups using data from the first year of the Low‐concentration Atropine for Myopia Progression (LAMP) study. Methods: The first year of the LAMP study was a robustly designed, placebo‐controlled trial of three different low concentrations of atropine using a large sample size (N > 100 randomised to each group). The authors subsequently published mean axial elongation and myopia progression rates by age group. We used these data to calculate efficacy in terms of both absolute reduction in myopic progression and absolute reduction in axial elongation for each of the different atropine concentrations at each age group. We then compared these efficacy data to the overall progression for each of the two progression metrics. Results: Plotting efficacy as a function of overall myopia progression and axial elongation for each of the different atropine concentrations demonstrates the invariant nature of efficacy, in terms of clinically meaningful reduction in progression, despite a substantial range of underlying overall progression. That is, faster progressors—the so‐called non‐responders—achieved similar reduction in axial elongation and myopia progression as the slower progressors—the so‐called responders—within the various atropine treatment groups. Conclusion: The use of the terms, responders and non‐responders, during myopia progression interventions is not supported by evidence. Those designated as such may simply be slower or faster progressors, who, on average achieve the same benefit from treatment. [ABSTRACT FROM AUTHOR]
Copyright of Ophthalmic & Physiological Optics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Psychology and Behavioral Sciences Collection
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: pbh
DbLabel: Psychology and Behavioral Sciences Collection
An: 180608769
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Can we really distinguish 'responders' from 'non‐responders' to myopia control interventions?
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Brennan%2C+Noel+A%2E%22">Brennan, Noel A.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nixon%2C+Alex+D%2E%22">Nixon, Alex D.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Cheng%2C+Xu%22">Cheng, Xu</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bullimore%2C+Mark+A%2E%22">Bullimore, Mark A.</searchLink> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Ophthalmic+%26+Physiological+Optics%22">Ophthalmic & Physiological Optics</searchLink>. Nov2024, Vol. 44 Issue 7, p1363-1367. 5p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Myopia%22">Myopia</searchLink><br /><searchLink fieldCode="DE" term="%22Atropine%22">Atropine</searchLink><br /><searchLink fieldCode="DE" term="%22Age+groups%22">Age groups</searchLink><br /><searchLink fieldCode="DE" term="%22Sample+size+%28Statistics%29%22">Sample size (Statistics)</searchLink><br /><searchLink fieldCode="DE" term="%22Lamps%22">Lamps</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: It is common to hear talk of 'responders' and 'non‐responders' with respect to myopia control interventions. We consider the reality of distinguishing these sub‐groups using data from the first year of the Low‐concentration Atropine for Myopia Progression (LAMP) study. Methods: The first year of the LAMP study was a robustly designed, placebo‐controlled trial of three different low concentrations of atropine using a large sample size (N > 100 randomised to each group). The authors subsequently published mean axial elongation and myopia progression rates by age group. We used these data to calculate efficacy in terms of both absolute reduction in myopic progression and absolute reduction in axial elongation for each of the different atropine concentrations at each age group. We then compared these efficacy data to the overall progression for each of the two progression metrics. Results: Plotting efficacy as a function of overall myopia progression and axial elongation for each of the different atropine concentrations demonstrates the invariant nature of efficacy, in terms of clinically meaningful reduction in progression, despite a substantial range of underlying overall progression. That is, faster progressors—the so‐called non‐responders—achieved similar reduction in axial elongation and myopia progression as the slower progressors—the so‐called responders—within the various atropine treatment groups. Conclusion: The use of the terms, responders and non‐responders, during myopia progression interventions is not supported by evidence. Those designated as such may simply be slower or faster progressors, who, on average achieve the same benefit from treatment. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Ophthalmic & Physiological Optics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=pbh&AN=180608769
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1111/opo.13379
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 5
        StartPage: 1363
    Subjects:
      – SubjectFull: Myopia
        Type: general
      – SubjectFull: Atropine
        Type: general
      – SubjectFull: Age groups
        Type: general
      – SubjectFull: Sample size (Statistics)
        Type: general
      – SubjectFull: Lamps
        Type: general
    Titles:
      – TitleFull: Can we really distinguish 'responders' from 'non‐responders' to myopia control interventions?
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Brennan, Noel A.
      – PersonEntity:
          Name:
            NameFull: Nixon, Alex D.
      – PersonEntity:
          Name:
            NameFull: Cheng, Xu
      – PersonEntity:
          Name:
            NameFull: Bullimore, Mark A.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 02755408
          Numbering:
            – Type: volume
              Value: 44
            – Type: issue
              Value: 7
          Titles:
            – TitleFull: Ophthalmic & Physiological Optics
              Type: main
ResultId 1