Jacobi–Fourier phase masks as ophthalmic elements to correct presbyopia.

Saved in:
Bibliographic Details
Title: Jacobi–Fourier phase masks as ophthalmic elements to correct presbyopia.
Authors: Salas‐Sanchez, Ángel (AUTHOR), González‐Amador, Enrique (AUTHOR), Padilla‐Vivanco, Alfonso (AUTHOR), Toxqui‐Quitl, Carina (AUTHOR), Arines, Justo (AUTHOR), Acosta, Eva (AUTHOR)
Source: Ophthalmic & Physiological Optics. Nov2024, Vol. 44 Issue 7, p1552-1560. 9p.
Subjects: Fourier transform optics, Visual optics, Achromatism, Visual acuity, Intraocular lenses
Abstract: Purpose: Investigations into the correction of presbyopia have considered lens design, clinical implications and the development of objective metrics such as the visual Strehl ratio. This study investigated the Jacobi–Fourier phase mask as an ophthalmic element in the correction of presbyopia. The goal was to develop a contact or intraocular lens whose performance was largely insensitive to changes in pupil diameter. Methods: Numerical simulations based on Fourier optics were performed to evaluate three different Jacobi–Fourier polynomials, with the aim of providing a range of clear vision (1 Dioptre (D)). Performance was evaluated for three pupil sizes (6, 4 and 2 mm), while polychromatic images were simulated using three different wavelengths (656.3, 587.6 and 486.1 nm). The Neural Transfer function was included in the simulation. To validate the method and results, we used the Visual Strehl combined objective metric (VSCombined) currently used in visual optics. This metric gives more weight to the phase transfer function and is more suitable for non‐symmetrical phase functions. Results: Numerical validation showed the suitability of the Jacobi–Fourier phase masks for extending the range of clear vision of presbyopic eyes, providing a visual acuity of at least 0.10 logMAR (6/7.5 Snellen) at all distances between 1 and 6 m. The results show a range of clear vision of 1D was not affected by changes in pupil size, an increase in retinal image contrast accompanied by image artefact reduction by increasing the radial order of the Jacobi–Fourier phase mask and a reduction of wavelength dependence of the retinal images. These results are supported by simulated images and the objective criterion VSCombined. Conclusions: The use of Jacobi–Fourier phase masks as ophthalmic elements for presbyopic correction show promising results, with a good range of clear vision and reduced dependence on pupil size and chromatic aberration. [ABSTRACT FROM AUTHOR]
Copyright of Ophthalmic & Physiological Optics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Psychology and Behavioral Sciences Collection
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: pbh
DbLabel: Psychology and Behavioral Sciences Collection
An: 180608779
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Jacobi–Fourier phase masks as ophthalmic elements to correct presbyopia.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Salas‐Sanchez%2C+Ángel%22">Salas‐Sanchez, Ángel</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22González‐Amador%2C+Enrique%22">González‐Amador, Enrique</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Padilla‐Vivanco%2C+Alfonso%22">Padilla‐Vivanco, Alfonso</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Toxqui‐Quitl%2C+Carina%22">Toxqui‐Quitl, Carina</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Arines%2C+Justo%22">Arines, Justo</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Acosta%2C+Eva%22">Acosta, Eva</searchLink> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Ophthalmic+%26+Physiological+Optics%22">Ophthalmic & Physiological Optics</searchLink>. Nov2024, Vol. 44 Issue 7, p1552-1560. 9p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Fourier+transform+optics%22">Fourier transform optics</searchLink><br /><searchLink fieldCode="DE" term="%22Visual+optics%22">Visual optics</searchLink><br /><searchLink fieldCode="DE" term="%22Achromatism%22">Achromatism</searchLink><br /><searchLink fieldCode="DE" term="%22Visual+acuity%22">Visual acuity</searchLink><br /><searchLink fieldCode="DE" term="%22Intraocular+lenses%22">Intraocular lenses</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: Investigations into the correction of presbyopia have considered lens design, clinical implications and the development of objective metrics such as the visual Strehl ratio. This study investigated the Jacobi–Fourier phase mask as an ophthalmic element in the correction of presbyopia. The goal was to develop a contact or intraocular lens whose performance was largely insensitive to changes in pupil diameter. Methods: Numerical simulations based on Fourier optics were performed to evaluate three different Jacobi–Fourier polynomials, with the aim of providing a range of clear vision (1 Dioptre (D)). Performance was evaluated for three pupil sizes (6, 4 and 2 mm), while polychromatic images were simulated using three different wavelengths (656.3, 587.6 and 486.1 nm). The Neural Transfer function was included in the simulation. To validate the method and results, we used the Visual Strehl combined objective metric (VSCombined) currently used in visual optics. This metric gives more weight to the phase transfer function and is more suitable for non‐symmetrical phase functions. Results: Numerical validation showed the suitability of the Jacobi–Fourier phase masks for extending the range of clear vision of presbyopic eyes, providing a visual acuity of at least 0.10 logMAR (6/7.5 Snellen) at all distances between 1 and 6 m. The results show a range of clear vision of 1D was not affected by changes in pupil size, an increase in retinal image contrast accompanied by image artefact reduction by increasing the radial order of the Jacobi–Fourier phase mask and a reduction of wavelength dependence of the retinal images. These results are supported by simulated images and the objective criterion VSCombined. Conclusions: The use of Jacobi–Fourier phase masks as ophthalmic elements for presbyopic correction show promising results, with a good range of clear vision and reduced dependence on pupil size and chromatic aberration. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Ophthalmic & Physiological Optics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=pbh&AN=180608779
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1111/opo.13389
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 1552
    Subjects:
      – SubjectFull: Fourier transform optics
        Type: general
      – SubjectFull: Visual optics
        Type: general
      – SubjectFull: Achromatism
        Type: general
      – SubjectFull: Visual acuity
        Type: general
      – SubjectFull: Intraocular lenses
        Type: general
    Titles:
      – TitleFull: Jacobi–Fourier phase masks as ophthalmic elements to correct presbyopia.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Salas‐Sanchez, Ángel
      – PersonEntity:
          Name:
            NameFull: González‐Amador, Enrique
      – PersonEntity:
          Name:
            NameFull: Padilla‐Vivanco, Alfonso
      – PersonEntity:
          Name:
            NameFull: Toxqui‐Quitl, Carina
      – PersonEntity:
          Name:
            NameFull: Arines, Justo
      – PersonEntity:
          Name:
            NameFull: Acosta, Eva
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 02755408
          Numbering:
            – Type: volume
              Value: 44
            – Type: issue
              Value: 7
          Titles:
            – TitleFull: Ophthalmic & Physiological Optics
              Type: main
ResultId 1