Modelling the thermal effects of stimulus airflow from the Dolphin aesthesiometer on a model eye surface.

Saved in:
Bibliographic Details
Title: Modelling the thermal effects of stimulus airflow from the Dolphin aesthesiometer on a model eye surface.
Authors: Mungalsingh, Melanie A. (AUTHOR), Thompson, Benjamin (AUTHOR), Peterson, Sean D. (AUTHOR), Murphy, Paul J. (AUTHOR)
Source: Ophthalmic & Physiological Optics. Mar2025, Vol. 45 Issue 2, p361-371. 11p.
Subjects: Cooling, Temperature effect, Sensory neurons, Statistical models, Thermography, Stimulus intensity
Abstract: Purpose: To assess the ability of the Dolphin air‐pulse aesthesiometer to present multiple stimuli, which are separated temporally (in sequence) or spatially (simultaneously). Methods: Two studies were performed to explore the cooling effects induced by double air‐puff stimuli generated by a novel aesthesiometer composed of two micro‐blower integrated units. The stimuli were delivered sequentially or simultaneously at the same or different spatial locations to an in vitro eye model monitored using thermography. The model eye was based on a 2‐cm LED dome light mounted on a circuit board with an 8‐V supply producing a baseline 32°C temperature. Single and repeated air‐pulse stimuli varying in intensity, duration, inter‐stimulus delay and stimulus location were presented to the model. The cooling effect produced was observed using a thermal camera and quantified using image analysis software. Results: The instrument can deliver single stimuli, repeated single stimuli with a variable time delay or multiple stimuli either simultaneously or with a time delay between them. The thermal effects of stimuli were evaluated by measuring (relative to pre‐stimulus baseline) the local temperature change and the diameter of the model eye surface region with ≥1°C reduction. Repeated stimuli at the same location produced a significantly greater effect than a single stimulus of the same intensity (larger area of cooling after the second stimulus compared to the first [|M|{SE} = 1.48 mm {0.06}, p < 0.001]). Spatially separated stimuli produced separate cooling zones, with the amount of cooling relative to stimulus intensity (rm‐ANOVA, F2,8 = 276.01, p < 0.001, ω2 = 0.96). Conclusions: The combined use of two micro‐blower units allows increased options for modification of stimulus intensity and timing of delivery that enables the production of alternative stimulus presentations and intensity compared to a single stimulus. This adaptability may enable future in vivo study of corneal sensory nerve summation. [ABSTRACT FROM AUTHOR]
Copyright of Ophthalmic & Physiological Optics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Psychology and Behavioral Sciences Collection
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: pbh
DbLabel: Psychology and Behavioral Sciences Collection
An: 183926120
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Modelling the thermal effects of stimulus airflow from the Dolphin aesthesiometer on a model eye surface.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Mungalsingh%2C+Melanie+A%2E%22&quot;&gt;Mungalsingh, Melanie A.&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Thompson%2C+Benjamin%22&quot;&gt;Thompson, Benjamin&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Peterson%2C+Sean+D%2E%22&quot;&gt;Peterson, Sean D.&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Murphy%2C+Paul+J%2E%22&quot;&gt;Murphy, Paul J.&lt;/searchLink&gt; (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Ophthalmic+%26+Physiological+Optics%22&quot;&gt;Ophthalmic &amp; Physiological Optics&lt;/searchLink&gt;. Mar2025, Vol. 45 Issue 2, p361-371. 11p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Cooling%22&quot;&gt;Cooling&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Temperature+effect%22&quot;&gt;Temperature effect&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Sensory+neurons%22&quot;&gt;Sensory neurons&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Statistical+models%22&quot;&gt;Statistical models&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Thermography%22&quot;&gt;Thermography&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Stimulus+intensity%22&quot;&gt;Stimulus intensity&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: To assess the ability of the Dolphin air‐pulse aesthesiometer to present multiple stimuli, which are separated temporally (in sequence) or spatially (simultaneously). Methods: Two studies were performed to explore the cooling effects induced by double air‐puff stimuli generated by a novel aesthesiometer composed of two micro‐blower integrated units. The stimuli were delivered sequentially or simultaneously at the same or different spatial locations to an in vitro eye model monitored using thermography. The model eye was based on a 2‐cm LED dome light mounted on a circuit board with an 8‐V supply producing a baseline 32&#176;C temperature. Single and repeated air‐pulse stimuli varying in intensity, duration, inter‐stimulus delay and stimulus location were presented to the model. The cooling effect produced was observed using a thermal camera and quantified using image analysis software. Results: The instrument can deliver single stimuli, repeated single stimuli with a variable time delay or multiple stimuli either simultaneously or with a time delay between them. The thermal effects of stimuli were evaluated by measuring (relative to pre‐stimulus baseline) the local temperature change and the diameter of the model eye surface region with ≥1&#176;C reduction. Repeated stimuli at the same location produced a significantly greater effect than a single stimulus of the same intensity (larger area of cooling after the second stimulus compared to the first [|M|{SE} = 1.48 mm {0.06}, p &lt; 0.001]). Spatially separated stimuli produced separate cooling zones, with the amount of cooling relative to stimulus intensity (rm‐ANOVA, F2,8 = 276.01, p &lt; 0.001, ω2 = 0.96). Conclusions: The combined use of two micro‐blower units allows increased options for modification of stimulus intensity and timing of delivery that enables the production of alternative stimulus presentations and intensity compared to a single stimulus. This adaptability may enable future in vivo study of corneal sensory nerve summation. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Ophthalmic &amp; Physiological Optics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=pbh&AN=183926120
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1111/opo.13436
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 361
    Subjects:
      – SubjectFull: Cooling
        Type: general
      – SubjectFull: Temperature effect
        Type: general
      – SubjectFull: Sensory neurons
        Type: general
      – SubjectFull: Statistical models
        Type: general
      – SubjectFull: Thermography
        Type: general
      – SubjectFull: Stimulus intensity
        Type: general
    Titles:
      – TitleFull: Modelling the thermal effects of stimulus airflow from the Dolphin aesthesiometer on a model eye surface.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Mungalsingh, Melanie A.
      – PersonEntity:
          Name:
            NameFull: Thompson, Benjamin
      – PersonEntity:
          Name:
            NameFull: Peterson, Sean D.
      – PersonEntity:
          Name:
            NameFull: Murphy, Paul J.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: Mar2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 02755408
          Numbering:
            – Type: volume
              Value: 45
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Ophthalmic & Physiological Optics
              Type: main