Exploring standard and low luminance visual acuity and the Moorfields Acuity Chart as outcome measures in inherited retinal disease.

Saved in:
Bibliographic Details
Title: Exploring standard and low luminance visual acuity and the Moorfields Acuity Chart as outcome measures in inherited retinal disease.
Authors: Taylor, Laura J. (AUTHOR), Josan, Amandeep S. (AUTHOR), MacLaren, Robert E. (AUTHOR)
Source: Ophthalmic & Physiological Optics. Jul2025, Vol. 45 Issue 5, p1158-1163. 6p.
Subjects: Visual acuity, Retinal diseases, Sensitivity & specificity (Statistics), Luminosity, Clinical trials, Statistical reliability
Abstract: Introduction: Standard visual acuity (VA) is often insensitive to subtle changes in vision that result from inherited retinal disease. Low luminance VA (LLVA) has grown in popularity as an alternative acuity measure. A new test, the Moorfields Acuity Chart (MAC) has been designed as a more sensitive and repeatable test for use in patients with age‐related macular degeneration. The study explores the utility and repeatability of standard VA, LLVA and the MAC in a mixed cohort of patients with inherited retinal disease. Methods: Participants were recruited as part of the visual function in retinal degeneration study (Ethics Reference 20/WM/0283). Standard VA was obtained using the Early Treatment of Diabetic Retinopathy study (ETDRS) chart placed at 4 m. LLVA was obtained using the same ETDRS chart with the addition of a 2.0‐log unit neutral density filter. MAC VA was obtained using standard clinic room lighting. All participants completed repeated testing. Results: Thirty‐five patient participants and 36 healthy controls, with logMAR 1.00 (6/60) or better, completed testing. Both LLVA and MAC VA were reduced compared to standard VA in patient participants and healthy controls (linear mixed model: p < 0.001). All three acuity tests show comparable sensitivity, specificity and repeatability. A subset of participants (patient participants n = 34, healthy controls n = 35) completed microperimetry. Post hoc analysis of microperimetry volume sensitivity correlated significantly with all of the acuity tests and showed no significant difference in the gradient of the slopes. This suggests that VA, LLVA and MAC VA decline at a consistent rate with disease progression. Conclusion: All three acuity tests could be considered viable outcome measures for clinical trials. For patients with early to moderate inherited retinal disease (logMAR 1.00 (6/60) or better), no single acuity chart appeared significantly beneficial. [ABSTRACT FROM AUTHOR]
Copyright of Ophthalmic & Physiological Optics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Psychology and Behavioral Sciences Collection
Full text is not displayed to guests.
Description
Abstract:Introduction: Standard visual acuity (VA) is often insensitive to subtle changes in vision that result from inherited retinal disease. Low luminance VA (LLVA) has grown in popularity as an alternative acuity measure. A new test, the Moorfields Acuity Chart (MAC) has been designed as a more sensitive and repeatable test for use in patients with age‐related macular degeneration. The study explores the utility and repeatability of standard VA, LLVA and the MAC in a mixed cohort of patients with inherited retinal disease. Methods: Participants were recruited as part of the visual function in retinal degeneration study (Ethics Reference 20/WM/0283). Standard VA was obtained using the Early Treatment of Diabetic Retinopathy study (ETDRS) chart placed at 4 m. LLVA was obtained using the same ETDRS chart with the addition of a 2.0‐log unit neutral density filter. MAC VA was obtained using standard clinic room lighting. All participants completed repeated testing. Results: Thirty‐five patient participants and 36 healthy controls, with logMAR 1.00 (6/60) or better, completed testing. Both LLVA and MAC VA were reduced compared to standard VA in patient participants and healthy controls (linear mixed model: p < 0.001). All three acuity tests show comparable sensitivity, specificity and repeatability. A subset of participants (patient participants n = 34, healthy controls n = 35) completed microperimetry. Post hoc analysis of microperimetry volume sensitivity correlated significantly with all of the acuity tests and showed no significant difference in the gradient of the slopes. This suggests that VA, LLVA and MAC VA decline at a consistent rate with disease progression. Conclusion: All three acuity tests could be considered viable outcome measures for clinical trials. For patients with early to moderate inherited retinal disease (logMAR 1.00 (6/60) or better), no single acuity chart appeared significantly beneficial. [ABSTRACT FROM AUTHOR]
ISSN:02755408
DOI:10.1111/opo.13504