The UMPIRE study: A first‐in‐human multicenter trial of bilateral subscalp monitoring for epileptic seizure detection.

Saved in:
Bibliographic Details
Title: The UMPIRE study: A first‐in‐human multicenter trial of bilateral subscalp monitoring for epileptic seizure detection.
Authors: Halliday, Amy J. (AUTHOR), Gillinder, Lisa (AUTHOR), Lai, Alan (AUTHOR), Seneviratne, Udaya (AUTHOR), Fontenot, Holly (AUTHOR), Cameron, Tracy (AUTHOR), McLean, Karen (AUTHOR), Niemiec, Andrew (AUTHOR), Raghupathi, Ramya (AUTHOR), Ganguly, Taneeta M. (AUTHOR), Ellis, Colin (AUTHOR), Conrad, Erin C. (AUTHOR), Briggs, Robert (AUTHOR), Bulluss, Kristian (AUTHOR), Kwan, Patrick (AUTHOR), Perucca, Piero (AUTHOR), O'Brien, Terence J. (AUTHOR), McGonigal, Aileen (AUTHOR), Gutman, Matthew (AUTHOR), Papacostas, Jason (AUTHOR)
Source: Epilepsia (Series 4). Sep2025, Vol. 66 Issue 9, p3426-3439. 14p.
Subjects: Epilepsy, Seizures (Medicine), Safety, Electroencephalography, Clinical trials, Neurophysiologic monitoring, Acquisition of data
Abstract: Objective: Patient self‐report is known to be an inaccurate reflection of true seizure frequency in persons with epilepsy. The current study aimed to assess the safety and performance of the Minder system, a bilateral subscalp electroencephalographic (EEG) acquisition system for continuous long‐term EEG recording. Methods: This prospective, multicenter first‐in‐human study enrolled adult patients with focal or generalized epilepsy and at least two seizures per month. The primary outcome was adverse events (AEs) in the first 6 months of implantation. Secondary analyses determined whether normal neurophysiological signals, interictal discharges, and seizures seen on scalp video‐EEG monitoring were identifiable on subscalp recordings, and signals were rated for clarity on subscalp and two‐channel scalp EEG recordings (1 = not recognizable, 5 = clear). Subscalp data were reviewed in relation to events reported in 6‐month seizures diaries. Results: Twenty‐six subjects were implanted between November 2019 and July 2023. No serious device‐ or implant procedure‐related AEs were reported. The most common device‐related AEs were mild or moderate postsurgical pain, headache, or scalp pain/paresthesia (9/26, 35%). All sleep spindles, chewing artifacts, interictal discharges, and electrographic seizures observed on scalp recordings (25 seizures from eight patients) were identified on subscalp recordings and given higher clarity ratings compared to two‐channel scalp recordings (median seizure clarity rating was 3 for both scalp and subscalp EEG, range = 1–5, p =.0025). Subscalp recordings captured seizures from diverse seizure focus locations, including frontal and mesial temporal seizure foci and hypothalamic hamartoma. Bilateral recording revealed clinically relevant findings not possible with unilateral recordings (6/26 patients, 23%). Findings of potential clinical utility were identified on manual review of 6‐month recordings in most patients (23/26, 88%). Significance: This study demonstrates the safety and performance of the Minder bilateral subscalp EEG acquisition system for long‐term seizure monitoring in patients with epilepsy. Bilateral hemisphere coverage captured seizures in a diverse patient group and permitted lateralization of events. [ABSTRACT FROM AUTHOR]
Copyright of Epilepsia (Series 4) is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Psychology and Behavioral Sciences Collection
FullText Text:
  Availability: 0
Header DbId: pbh
DbLabel: Psychology and Behavioral Sciences Collection
An: 188366456
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: The UMPIRE study: A first‐in‐human multicenter trial of bilateral subscalp monitoring for epileptic seizure detection.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Halliday%2C+Amy+J%2E%22">Halliday, Amy J.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Gillinder%2C+Lisa%22">Gillinder, Lisa</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lai%2C+Alan%22">Lai, Alan</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Seneviratne%2C+Udaya%22">Seneviratne, Udaya</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Fontenot%2C+Holly%22">Fontenot, Holly</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Cameron%2C+Tracy%22">Cameron, Tracy</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22McLean%2C+Karen%22">McLean, Karen</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Niemiec%2C+Andrew%22">Niemiec, Andrew</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Raghupathi%2C+Ramya%22">Raghupathi, Ramya</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ganguly%2C+Taneeta+M%2E%22">Ganguly, Taneeta M.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ellis%2C+Colin%22">Ellis, Colin</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Conrad%2C+Erin+C%2E%22">Conrad, Erin C.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Briggs%2C+Robert%22">Briggs, Robert</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bulluss%2C+Kristian%22">Bulluss, Kristian</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kwan%2C+Patrick%22">Kwan, Patrick</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Perucca%2C+Piero%22">Perucca, Piero</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22O'Brien%2C+Terence+J%2E%22">O'Brien, Terence J.</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22McGonigal%2C+Aileen%22">McGonigal, Aileen</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Gutman%2C+Matthew%22">Gutman, Matthew</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Papacostas%2C+Jason%22">Papacostas, Jason</searchLink> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Epilepsia+%28Series+4%29%22">Epilepsia (Series 4)</searchLink>. Sep2025, Vol. 66 Issue 9, p3426-3439. 14p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Epilepsy%22">Epilepsy</searchLink><br /><searchLink fieldCode="DE" term="%22Seizures+%28Medicine%29%22">Seizures (Medicine)</searchLink><br /><searchLink fieldCode="DE" term="%22Safety%22">Safety</searchLink><br /><searchLink fieldCode="DE" term="%22Electroencephalography%22">Electroencephalography</searchLink><br /><searchLink fieldCode="DE" term="%22Clinical+trials%22">Clinical trials</searchLink><br /><searchLink fieldCode="DE" term="%22Neurophysiologic+monitoring%22">Neurophysiologic monitoring</searchLink><br /><searchLink fieldCode="DE" term="%22Acquisition+of+data%22">Acquisition of data</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Objective: Patient self‐report is known to be an inaccurate reflection of true seizure frequency in persons with epilepsy. The current study aimed to assess the safety and performance of the Minder system, a bilateral subscalp electroencephalographic (EEG) acquisition system for continuous long‐term EEG recording. Methods: This prospective, multicenter first‐in‐human study enrolled adult patients with focal or generalized epilepsy and at least two seizures per month. The primary outcome was adverse events (AEs) in the first 6 months of implantation. Secondary analyses determined whether normal neurophysiological signals, interictal discharges, and seizures seen on scalp video‐EEG monitoring were identifiable on subscalp recordings, and signals were rated for clarity on subscalp and two‐channel scalp EEG recordings (1 = not recognizable, 5 = clear). Subscalp data were reviewed in relation to events reported in 6‐month seizures diaries. Results: Twenty‐six subjects were implanted between November 2019 and July 2023. No serious device‐ or implant procedure‐related AEs were reported. The most common device‐related AEs were mild or moderate postsurgical pain, headache, or scalp pain/paresthesia (9/26, 35%). All sleep spindles, chewing artifacts, interictal discharges, and electrographic seizures observed on scalp recordings (25 seizures from eight patients) were identified on subscalp recordings and given higher clarity ratings compared to two‐channel scalp recordings (median seizure clarity rating was 3 for both scalp and subscalp EEG, range = 1–5, p =.0025). Subscalp recordings captured seizures from diverse seizure focus locations, including frontal and mesial temporal seizure foci and hypothalamic hamartoma. Bilateral recording revealed clinically relevant findings not possible with unilateral recordings (6/26 patients, 23%). Findings of potential clinical utility were identified on manual review of 6‐month recordings in most patients (23/26, 88%). Significance: This study demonstrates the safety and performance of the Minder bilateral subscalp EEG acquisition system for long‐term seizure monitoring in patients with epilepsy. Bilateral hemisphere coverage captured seizures in a diverse patient group and permitted lateralization of events. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Epilepsia (Series 4) is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=pbh&AN=188366456
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1111/epi.18458
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 14
        StartPage: 3426
    Subjects:
      – SubjectFull: Epilepsy
        Type: general
      – SubjectFull: Seizures (Medicine)
        Type: general
      – SubjectFull: Safety
        Type: general
      – SubjectFull: Electroencephalography
        Type: general
      – SubjectFull: Clinical trials
        Type: general
      – SubjectFull: Neurophysiologic monitoring
        Type: general
      – SubjectFull: Acquisition of data
        Type: general
    Titles:
      – TitleFull: The UMPIRE study: A first‐in‐human multicenter trial of bilateral subscalp monitoring for epileptic seizure detection.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Halliday, Amy J.
      – PersonEntity:
          Name:
            NameFull: Gillinder, Lisa
      – PersonEntity:
          Name:
            NameFull: Lai, Alan
      – PersonEntity:
          Name:
            NameFull: Seneviratne, Udaya
      – PersonEntity:
          Name:
            NameFull: Fontenot, Holly
      – PersonEntity:
          Name:
            NameFull: Cameron, Tracy
      – PersonEntity:
          Name:
            NameFull: McLean, Karen
      – PersonEntity:
          Name:
            NameFull: Niemiec, Andrew
      – PersonEntity:
          Name:
            NameFull: Raghupathi, Ramya
      – PersonEntity:
          Name:
            NameFull: Ganguly, Taneeta M.
      – PersonEntity:
          Name:
            NameFull: Ellis, Colin
      – PersonEntity:
          Name:
            NameFull: Conrad, Erin C.
      – PersonEntity:
          Name:
            NameFull: Briggs, Robert
      – PersonEntity:
          Name:
            NameFull: Bulluss, Kristian
      – PersonEntity:
          Name:
            NameFull: Kwan, Patrick
      – PersonEntity:
          Name:
            NameFull: Perucca, Piero
      – PersonEntity:
          Name:
            NameFull: O'Brien, Terence J.
      – PersonEntity:
          Name:
            NameFull: McGonigal, Aileen
      – PersonEntity:
          Name:
            NameFull: Gutman, Matthew
      – PersonEntity:
          Name:
            NameFull: Papacostas, Jason
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: Sep2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 00139580
          Numbering:
            – Type: volume
              Value: 66
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: Epilepsia (Series 4)
              Type: main
ResultId 1