Investigation of formaldehyde sources in French schools using a passive flux sampler.

Saved in:
Bibliographic Details
Title: Investigation of formaldehyde sources in French schools using a passive flux sampler.
Authors: Poulhet, G.1,2,3, Dusanter, S.1,2,4 sebastien.dusanter@mines-douai.fr, Crunaire, S.1,2, Locoge, N.1,2, Gaudion, V.1,2, Merlen, C.1,2, Kaluzny, P.3, Coddeville, P.1,2
Source: Building & Environment. Jan2014, Vol. 71, p111-120. 10p.
Subject Terms: *Formaldehyde, *Indoor air quality, *Indoor air pollution, *Emissions (Air pollution), French schools abroad, Adverse health care events
Abstract: Abstract: While indoor air quality issues have received increasing attention the past decades, detailed investigations of primary sources of indoor pollution are still difficult to carry out. There is a lack of analytical tools and measurement procedures to identify sources of pollutants and to characterize their emissions. Formaldehyde is a ubiquitous pollutant in indoor environments, which is known to lead to adverse health effects. This study describes a measurement procedure to apportion formaldehyde emissions from building and furnishing materials and presents a source apportionment study performed in French public schools. More than 29 sources of formaldehyde were characterized in each investigated classroom, with higher emissions from building materials compared to furnishing materials. Formaldehyde emission rates measured using passive flux samplers (PFS) range from 1.2 to 252 μg/m2/h, highlighting several strong emitters made of wood products and foam. Interestingly, the ceiling was identified as the main source of formaldehyde in most classrooms. Measured emissions and air exchange rates were constrained in a mass balance model to evaluate the impact of formaldehyde reduction strategies. These results indicate that formaldehyde concentrations can be reduced by 87–98% by removing or replacing the main source of emission by a less emissive material and by increasing the air exchange rate to 1 h−1. In addition, an intercomparison of total emissions calculated from (1) PFS measurements and from (2) measured formaldehyde concentrations and air exchange rates indicate that an unidentified sink of formaldehyde may exist in indoor environments. [Copyright &y& Elsevier]
Copyright of Building & Environment is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: GreenFILE
Description
Abstract:Abstract: While indoor air quality issues have received increasing attention the past decades, detailed investigations of primary sources of indoor pollution are still difficult to carry out. There is a lack of analytical tools and measurement procedures to identify sources of pollutants and to characterize their emissions. Formaldehyde is a ubiquitous pollutant in indoor environments, which is known to lead to adverse health effects. This study describes a measurement procedure to apportion formaldehyde emissions from building and furnishing materials and presents a source apportionment study performed in French public schools. More than 29 sources of formaldehyde were characterized in each investigated classroom, with higher emissions from building materials compared to furnishing materials. Formaldehyde emission rates measured using passive flux samplers (PFS) range from 1.2 to 252 μg/m2/h, highlighting several strong emitters made of wood products and foam. Interestingly, the ceiling was identified as the main source of formaldehyde in most classrooms. Measured emissions and air exchange rates were constrained in a mass balance model to evaluate the impact of formaldehyde reduction strategies. These results indicate that formaldehyde concentrations can be reduced by 87–98% by removing or replacing the main source of emission by a less emissive material and by increasing the air exchange rate to 1 h−1. In addition, an intercomparison of total emissions calculated from (1) PFS measurements and from (2) measured formaldehyde concentrations and air exchange rates indicate that an unidentified sink of formaldehyde may exist in indoor environments. [Copyright &y& Elsevier]
ISSN:03601323
DOI:10.1016/j.buildenv.2013.10.002