Investigation of formaldehyde sources in French schools using a passive flux sampler.

Saved in:
Bibliographic Details
Title: Investigation of formaldehyde sources in French schools using a passive flux sampler.
Authors: Poulhet, G.1,2,3, Dusanter, S.1,2,4 sebastien.dusanter@mines-douai.fr, Crunaire, S.1,2, Locoge, N.1,2, Gaudion, V.1,2, Merlen, C.1,2, Kaluzny, P.3, Coddeville, P.1,2
Source: Building & Environment. Jan2014, Vol. 71, p111-120. 10p.
Subject Terms: *Formaldehyde, *Indoor air quality, *Indoor air pollution, *Emissions (Air pollution), French schools abroad, Adverse health care events
Abstract: Abstract: While indoor air quality issues have received increasing attention the past decades, detailed investigations of primary sources of indoor pollution are still difficult to carry out. There is a lack of analytical tools and measurement procedures to identify sources of pollutants and to characterize their emissions. Formaldehyde is a ubiquitous pollutant in indoor environments, which is known to lead to adverse health effects. This study describes a measurement procedure to apportion formaldehyde emissions from building and furnishing materials and presents a source apportionment study performed in French public schools. More than 29 sources of formaldehyde were characterized in each investigated classroom, with higher emissions from building materials compared to furnishing materials. Formaldehyde emission rates measured using passive flux samplers (PFS) range from 1.2 to 252 μg/m2/h, highlighting several strong emitters made of wood products and foam. Interestingly, the ceiling was identified as the main source of formaldehyde in most classrooms. Measured emissions and air exchange rates were constrained in a mass balance model to evaluate the impact of formaldehyde reduction strategies. These results indicate that formaldehyde concentrations can be reduced by 87–98% by removing or replacing the main source of emission by a less emissive material and by increasing the air exchange rate to 1 h−1. In addition, an intercomparison of total emissions calculated from (1) PFS measurements and from (2) measured formaldehyde concentrations and air exchange rates indicate that an unidentified sink of formaldehyde may exist in indoor environments. [Copyright &y& Elsevier]
Copyright of Building & Environment is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: GreenFILE
FullText Text:
  Availability: 0
Header DbId: 8gh
DbLabel: GreenFILE
An: 92651630
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Investigation of formaldehyde sources in French schools using a passive flux sampler.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Poulhet%2C+G%2E%22">Poulhet, G.</searchLink><relatesTo>1,2,3</relatesTo><br /><searchLink fieldCode="AR" term="%22Dusanter%2C+S%2E%22">Dusanter, S.</searchLink><relatesTo>1,2,4</relatesTo><i> sebastien.dusanter@mines-douai.fr</i><br /><searchLink fieldCode="AR" term="%22Crunaire%2C+S%2E%22">Crunaire, S.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Locoge%2C+N%2E%22">Locoge, N.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Gaudion%2C+V%2E%22">Gaudion, V.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Merlen%2C+C%2E%22">Merlen, C.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Kaluzny%2C+P%2E%22">Kaluzny, P.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Coddeville%2C+P%2E%22">Coddeville, P.</searchLink><relatesTo>1,2</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Building+%26+Environment%22">Building & Environment</searchLink>. Jan2014, Vol. 71, p111-120. 10p.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Formaldehyde%22">Formaldehyde</searchLink><br />*<searchLink fieldCode="DE" term="%22Indoor+air+quality%22">Indoor air quality</searchLink><br />*<searchLink fieldCode="DE" term="%22Indoor+air+pollution%22">Indoor air pollution</searchLink><br />*<searchLink fieldCode="DE" term="%22Emissions+%28Air+pollution%29%22">Emissions (Air pollution)</searchLink><br /><searchLink fieldCode="DE" term="%22French+schools+abroad%22">French schools abroad</searchLink><br /><searchLink fieldCode="DE" term="%22Adverse+health+care+events%22">Adverse health care events</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Abstract: While indoor air quality issues have received increasing attention the past decades, detailed investigations of primary sources of indoor pollution are still difficult to carry out. There is a lack of analytical tools and measurement procedures to identify sources of pollutants and to characterize their emissions. Formaldehyde is a ubiquitous pollutant in indoor environments, which is known to lead to adverse health effects. This study describes a measurement procedure to apportion formaldehyde emissions from building and furnishing materials and presents a source apportionment study performed in French public schools. More than 29 sources of formaldehyde were characterized in each investigated classroom, with higher emissions from building materials compared to furnishing materials. Formaldehyde emission rates measured using passive flux samplers (PFS) range from 1.2 to 252 μg/m2/h, highlighting several strong emitters made of wood products and foam. Interestingly, the ceiling was identified as the main source of formaldehyde in most classrooms. Measured emissions and air exchange rates were constrained in a mass balance model to evaluate the impact of formaldehyde reduction strategies. These results indicate that formaldehyde concentrations can be reduced by 87–98% by removing or replacing the main source of emission by a less emissive material and by increasing the air exchange rate to 1 h−1. In addition, an intercomparison of total emissions calculated from (1) PFS measurements and from (2) measured formaldehyde concentrations and air exchange rates indicate that an unidentified sink of formaldehyde may exist in indoor environments. [Copyright &y& Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Building & Environment is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=8gh&AN=92651630
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.buildenv.2013.10.002
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 111
    Subjects:
      – SubjectFull: Formaldehyde
        Type: general
      – SubjectFull: Indoor air quality
        Type: general
      – SubjectFull: Indoor air pollution
        Type: general
      – SubjectFull: Emissions (Air pollution)
        Type: general
      – SubjectFull: French schools abroad
        Type: general
      – SubjectFull: Adverse health care events
        Type: general
    Titles:
      – TitleFull: Investigation of formaldehyde sources in French schools using a passive flux sampler.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Poulhet, G.
      – PersonEntity:
          Name:
            NameFull: Dusanter, S.
      – PersonEntity:
          Name:
            NameFull: Crunaire, S.
      – PersonEntity:
          Name:
            NameFull: Locoge, N.
      – PersonEntity:
          Name:
            NameFull: Gaudion, V.
      – PersonEntity:
          Name:
            NameFull: Merlen, C.
      – PersonEntity:
          Name:
            NameFull: Kaluzny, P.
      – PersonEntity:
          Name:
            NameFull: Coddeville, P.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Text: Jan2014
              Type: published
              Y: 2014
          Identifiers:
            – Type: issn-print
              Value: 03601323
          Numbering:
            – Type: volume
              Value: 71
          Titles:
            – TitleFull: Building & Environment
              Type: main
ResultId 1