HVDC pollution testing of insulation: experience from service, laboratory and test station.

Saved in:
Bibliographic Details
Title: HVDC pollution testing of insulation: experience from service, laboratory and test station.
Authors: Windmar, Dan1, Gutman, Igor1, Jonsson, Johan1
Source: IEEE Transactions on Dielectrics & Electrical Insulation. Dec2014, Vol. 21 Issue 6, p2496-2502. 7p.
Subjects: Electric lines testing, High-voltage direct current transmission, Electric insulators & insulation, Electric cables, Dielectrics, Electric instrument transformers
Abstract: The need for testing at HVDC and UHVDC levels has increased dramatically over the last few years. Typically test objects include valves, cables, line insulators, cable accessories, optical instrument transformers and station post insulators. Some of these tests are dielectric tests and in many cases the tests include also pollution testing, which is a main dimensioning parameter for outdoor insulation in DC. This publication focuses on the experience that STRI has gained throughout years of investigating and testing insulators under HVDC in polluted conditions. Examples from service and field stations and laboratory investigations of artificially and naturally polluted ceramic and polymeric insulators are presented. Examples of practical implementation of laboratory results in design practice are also given. [ABSTRACT FROM PUBLISHER]
Copyright of IEEE Transactions on Dielectrics & Electrical Insulation is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:The need for testing at HVDC and UHVDC levels has increased dramatically over the last few years. Typically test objects include valves, cables, line insulators, cable accessories, optical instrument transformers and station post insulators. Some of these tests are dielectric tests and in many cases the tests include also pollution testing, which is a main dimensioning parameter for outdoor insulation in DC. This publication focuses on the experience that STRI has gained throughout years of investigating and testing insulators under HVDC in polluted conditions. Examples from service and field stations and laboratory investigations of artificially and naturally polluted ceramic and polymeric insulators are presented. Examples of practical implementation of laboratory results in design practice are also given. [ABSTRACT FROM PUBLISHER]
ISSN:10709878
DOI:10.1109/TDEI.2014.004605