Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method.

Saved in:
Bibliographic Details
Title: Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method.
Authors: Wang, Adam S.1, Stayman, J. Webster1, Otake, Yoshito1, Vogt, Sebastian2, Kleinszig, Gerhard2, Siewerdsen, Jeffrey H.1
Source: Medical Physics. May2015, Vol. 42 Issue 5, p2699-2708. 10p.
Subjects: Computed tomography, Image reconstruction, Radiation doses, Image quality analysis, Algorithms, Computer-assisted surgery
Abstract: Purpose: To accelerate model-based iterative reconstruction (IR) methods for C-arm cone-beam CT (CBCT), thereby combining the benefits of improved image quality and/or reduced radiation dose with reconstruction times on the order of minutes rather than hours. Methods: The ordered-subsets, separable quadratic surrogates (OS-SQS) algorithm for solving the penalized-likelihood (PL) objective was modified to include Nesterov's method, which utilizes "momentum" from image updates of previous iterations to better inform the current iteration and provide significantly faster convergence. Reconstruction performance of an anthropomorphic head phantom was assessed on a benchtop CBCT system, followed by CBCT on a mobile C-arm, which provided typical levels of incomplete data, including lateral truncation. Additionally, a cadaveric torso that presented realistic soft-tissue and bony anatomy was imaged on the C-arm, and different projectors were assessed for reconstruction speed. Results: Nesterov's method provided equivalent image quality to OS-SQS while reducing the reconstruction time by an order of magnitude (10.0×) by reducing the number of iterations required for convergence. The faster projectors were shown to produce similar levels of convergence as more accurate projectors and reduced the reconstruction time by another 5.3×. Despite the slower convergence of IR with truncated C-arm CBCT, comparison of PL reconstruction methods implemented on graphics processing units showed that reconstruction time was reduced from 106 min for the conventional OS-SQS method to as little as 2.0 min with Nesterov's method for a volumetric reconstruction of the head. In body imaging, reconstruction of the larger cadaveric torso was reduced from 159 min down to 3.3 min with Nesterov's method. Conclusions: The acceleration achieved through Nesterov's method combined with ordered subsets reduced IR times down to a few minutes. This improved compatibility with clinical workflow better enables broader adoption of IR in CBCT-guided procedures, with corresponding benefits in overcoming conventional limits of image quality at lower dose. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 102751321
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Wang%2C+Adam+S%2E%22">Wang, Adam S.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Stayman%2C+J%2E+Webster%22">Stayman, J. Webster</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Otake%2C+Yoshito%22">Otake, Yoshito</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Vogt%2C+Sebastian%22">Vogt, Sebastian</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Kleinszig%2C+Gerhard%22">Kleinszig, Gerhard</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Siewerdsen%2C+Jeffrey+H%2E%22">Siewerdsen, Jeffrey H.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. May2015, Vol. 42 Issue 5, p2699-2708. 10p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Image+reconstruction%22">Image reconstruction</searchLink><br /><searchLink fieldCode="DE" term="%22Radiation+doses%22">Radiation doses</searchLink><br /><searchLink fieldCode="DE" term="%22Image+quality+analysis%22">Image quality analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Algorithms%22">Algorithms</searchLink><br /><searchLink fieldCode="DE" term="%22Computer-assisted+surgery%22">Computer-assisted surgery</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: To accelerate model-based iterative reconstruction (IR) methods for C-arm cone-beam CT (CBCT), thereby combining the benefits of improved image quality and/or reduced radiation dose with reconstruction times on the order of minutes rather than hours. Methods: The ordered-subsets, separable quadratic surrogates (OS-SQS) algorithm for solving the penalized-likelihood (PL) objective was modified to include Nesterov's method, which utilizes "momentum" from image updates of previous iterations to better inform the current iteration and provide significantly faster convergence. Reconstruction performance of an anthropomorphic head phantom was assessed on a benchtop CBCT system, followed by CBCT on a mobile C-arm, which provided typical levels of incomplete data, including lateral truncation. Additionally, a cadaveric torso that presented realistic soft-tissue and bony anatomy was imaged on the C-arm, and different projectors were assessed for reconstruction speed. Results: Nesterov's method provided equivalent image quality to OS-SQS while reducing the reconstruction time by an order of magnitude (10.0×) by reducing the number of iterations required for convergence. The faster projectors were shown to produce similar levels of convergence as more accurate projectors and reduced the reconstruction time by another 5.3×. Despite the slower convergence of IR with truncated C-arm CBCT, comparison of PL reconstruction methods implemented on graphics processing units showed that reconstruction time was reduced from 106 min for the conventional OS-SQS method to as little as 2.0 min with Nesterov's method for a volumetric reconstruction of the head. In body imaging, reconstruction of the larger cadaveric torso was reduced from 159 min down to 3.3 min with Nesterov's method. Conclusions: The acceleration achieved through Nesterov's method combined with ordered subsets reduced IR times down to a few minutes. This improved compatibility with clinical workflow better enables broader adoption of IR in CBCT-guided procedures, with corresponding benefits in overcoming conventional limits of image quality at lower dose. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=102751321
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1118/1.4914378
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 2699
    Subjects:
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: Image reconstruction
        Type: general
      – SubjectFull: Radiation doses
        Type: general
      – SubjectFull: Image quality analysis
        Type: general
      – SubjectFull: Algorithms
        Type: general
      – SubjectFull: Computer-assisted surgery
        Type: general
    Titles:
      – TitleFull: Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Wang, Adam S.
      – PersonEntity:
          Name:
            NameFull: Stayman, J. Webster
      – PersonEntity:
          Name:
            NameFull: Otake, Yoshito
      – PersonEntity:
          Name:
            NameFull: Vogt, Sebastian
      – PersonEntity:
          Name:
            NameFull: Kleinszig, Gerhard
      – PersonEntity:
          Name:
            NameFull: Siewerdsen, Jeffrey H.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Text: May2015
              Type: published
              Y: 2015
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 42
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1