Contrast enhanced ultrasound in the detection of liver metastases: a prospective multi-centre dose testing study using a perfluorobutane microbubble contrast agent (NC100100).
Saved in:
| Title: | Contrast enhanced ultrasound in the detection of liver metastases: a prospective multi-centre dose testing study using a perfluorobutane microbubble contrast agent (NC100100). |
|---|---|
| Authors: | Correas JM (AUTHOR), Low G (AUTHOR), Needleman L (AUTHOR), Robbin ML (AUTHOR), Cosgrove D (AUTHOR), Sidhu PS (AUTHOR), Harvey CJ (AUTHOR), Albrecht T (AUTHOR), Jakobsen JA (AUTHOR), Brabrand K (AUTHOR), Jenett M (AUTHOR), Bates J (AUTHOR), Claudon M (AUTHOR), Leen E (AUTHOR), Correas, Jean-Michel1 (AUTHOR), Low, Gavin (AUTHOR), Needleman, Laurence (AUTHOR), Robbin, Michelle L (AUTHOR), Cosgrove, David (AUTHOR), Sidhu, Paul S (AUTHOR) |
| Source: | European Radiology. Aug2011, Vol. 21 Issue 8, p1739-1746. 8p. |
| Abstract: | |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | <bold>Objective: </bold>To conduct a dose testing analysis of perfluorobutane microbubble (NC100100) contrast-enhanced ultrasound (CEUS) to determine the optimal dose for detection of liver metastases in patients with extra-hepatic primary malignancy.<bold>Methods: </bold>157 patients were investigated with conventional US and CEUS. CEUS was performed following intravenous administration of perfluorobutane microbubbles (using one dose of either 0.008, 0.08, 0.12 or 0.36 μL/kg body weight). Three blinded off-site readers recorded the number and locations of metastatic lesions detected by US and CEUS. Contrast enhanced CT and MRI were used as the "Standard Of Reference" (SOR). Sensitivity, specificity and accuracy of liver metastasis detection with US versus CEUS, for each dose group were obtained. Dose group analysis was performed using the Chi-square test.<bold>Results: </bold>165 metastases were present in 92 patients who each had 1-7 lesions present on the SOR. Sensitivity of US versus CEUS (for all doses combined) was 38% and 67% (p = 0.0001). The 0.12 dose group with CEUS (78%) had significantly higher sensitivity and accuracy (70%) compared to other dose groups (p < 0.05).<bold>Conclusion: </bold>The diagnostic performance of CEUS is dose dependent with the 0.12 μL/kg NC100100 dose group showing the greatest sensitivity and accuracy in detection of liver metastases. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 09387994 |
| DOI: | 10.1007/s00330-011-2114-6 |