Bibliographic Details
| Title: |
Computational analysis of blood clot dissolution using a vibrating catheter tip. |
| Authors: |
Lee JH (AUTHOR), Oh JS (AUTHOR), Yoon BR (AUTHOR), Choi SH (AUTHOR), Rhee K (AUTHOR), Jho JY (AUTHOR), Han MH (AUTHOR), Lee, Jeong Hyun1 (AUTHOR), Oh, Jin Sun (AUTHOR), Yoon, Bye Ri (AUTHOR), Choi, Seung Hong (AUTHOR), Rhee, Kyehan (AUTHOR), Jho, Jae Young (AUTHOR), Han, Moon Hee (AUTHOR) |
| Source: |
Proceedings of the Institution of Mechanical Engineers -- Part H -- Journal of Engineering in Medicine (Professional Engineering Publishing). 2012 Apr, Vol. 226 Issue 4, p337-340. 4p. |
| Abstract: |
We developed a novel concept of endovascular thrombolysis that employs a vibrating electroactive polymer actuator. In order to predict the efficacy of thrombolysis using the developed vibrating actuator, enzyme (plasminogen activator) perfusion into a clot was analyzed by solving flow fields and species transport equations considering the fluid structure interaction. In vitro thrombolysis experiments were also performed. Computational results showed that plasminogen activator perfusion into a clot was enhanced by actuator vibration at frequencies of 1 and 5 Hz. Plasminogen activator perfusion was affected by the actuator oscillation frequencies and amplitudes that were determined by electromechanical characteristics of a polymer actuator. Computed plasminogen activator perfused volumes were compared with experimentally measured dissolved clot volumes. The computed plasminogen activator perfusion volumes with threshold concentrations of 16% of the initial plasminogen activator concentration agreed well with the in vitro experimental data. This study showed the effectiveness of actuator oscillation on thrombolysis and the validity of the computational plasminogen activator perfusion model for predicting thrombolysis in complex flow fields induced by an oscillating actuator. [ABSTRACT FROM AUTHOR] |
|
Copyright of Proceedings of the Institution of Mechanical Engineers -- Part H -- Journal of Engineering in Medicine (Professional Engineering Publishing) is the property of Professional Engineering Publishing and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
Engineering Source |