The laser and optical system for the RIBF-PALIS experiment.

Saved in:
Bibliographic Details
Title: The laser and optical system for the RIBF-PALIS experiment.
Authors: Sonoda, T.1 tetsu@riken.jp, Iimura, H.1,2, Reponen, M.3, Wada, M.1,4, Katayama, I.1, Sonnenschein, V.1,5, Takamatsu, T.1,5, Tomita, H.1,5, Kojima, T.M.1
Source: Nuclear Instruments & Methods in Physics Research Section A. Jan2018, Vol. 877, p118-123. 6p.
Subjects: Laser spectroscopy, Radioisotopes, Light sources, Gas vans (Gas chambers), Resonance ionization spectroscopy, Laser beams
Abstract: This paper describes the laser and optical system for the Parasitic radioactive isotope (RI) beam production by Laser Ion-Source (PALIS) in the RIKEN fragment separator facility. This system requires an optical path length of 70 m for transporting the laser beam from the laser light source to the place for resonance ionization. To accomplish this, we designed and implemented a simple optical system consisting of several mirrors equipped with compact stepping motor actuators, lenses, beam spot screens and network cameras. The system enables multi-step laser resonance ionization in the gas cell and gas jet via overlap with a diameter of a few millimeters, between the laser photons and atomic beam. Despite such a long transport distance, we achieved a transport efficiency for the UV laser beam of about 50%. We also confirmed that the position stability of the laser beam stays within a permissible range for dedicated resonance ionization experiments. [ABSTRACT FROM AUTHOR]
Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:This paper describes the laser and optical system for the Parasitic radioactive isotope (RI) beam production by Laser Ion-Source (PALIS) in the RIKEN fragment separator facility. This system requires an optical path length of 70 m for transporting the laser beam from the laser light source to the place for resonance ionization. To accomplish this, we designed and implemented a simple optical system consisting of several mirrors equipped with compact stepping motor actuators, lenses, beam spot screens and network cameras. The system enables multi-step laser resonance ionization in the gas cell and gas jet via overlap with a diameter of a few millimeters, between the laser photons and atomic beam. Despite such a long transport distance, we achieved a transport efficiency for the UV laser beam of about 50%. We also confirmed that the position stability of the laser beam stays within a permissible range for dedicated resonance ionization experiments. [ABSTRACT FROM AUTHOR]
ISSN:01689002
DOI:10.1016/j.nima.2017.09.055