Mesenteric lymph nodes in MR enterography: are they reliable followers of bowel in active Crohn's disease?

Saved in:
Bibliographic Details
Title: Mesenteric lymph nodes in MR enterography: are they reliable followers of bowel in active Crohn's disease?
Authors: Radmard, Amir Reza1 radmard@tums.ac.ir, amir.radmard@gmail.com, Eftekhar Vaghefi, Rana1, Montazeri, Seyed Ali2, Naybandi Atashi, Sara1, Hashemi Taheri, Amir Pejman1, Haghighi, Sepehr1, Salehnia, Aneseh1, Dadgostar, Mehrdad3, Malekzadeh, Reza2
Source: European Radiology. Oct2018, Vol. 28 Issue 10, p4429-4437. 9p. 3 Black and White Photographs, 1 Diagram, 4 Charts.
Subjects: Lymph node diseases, Mesentery tumors, Crohn's disease, Diffusion coefficients, Signal-to-noise ratio, Contrast-enhanced magnetic resonance imaging, Diffusion magnetic resonance imaging, Contrast media, Patients
Abstract: Objectives: To demonstrate magnetic resonance enterography (MRE) features of mesenteric lymph nodes (LN) in patients with Crohn's disease (CD) and investigate whether they follow enhancement or apparent diffusion coefficient (ADC) parameters of bowel.Methods: This study was approved by the institutional review board. A total of 788 MREs from patients with CD were retrospectively reviewed. Eighty-eight patients, aged 16-66 years, including 59 active cases, were enrolled based on inclusion criteria. In each MRE, two segments (normal and abnormal) and two LNs (regional and non-regional) were independently suggested, consensually chosen, and analyzed by two radiologists. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated to assess signal intensities (SI) at 30, 60 and 180 s after contrast administration, as well as slope of enhancement (SOE). Enhancement parameters and ADC values were compared.Results: Regional LNs showed significantly higher SI30, SI60 and SI180 (CNR&SNR) and lower ADC values in active vs. inactive groups (all p<0.05) without significant difference in number or size. Strong correlations were demonstrated between abnormal segments and regional LNs in active group in terms of SI30, SI60, SI180, SOE0-30 and ADC values (r = 0.679 to 0.774, all p<0.001). SI180, SOE60-180 and ADC values were moderately correlated between abnormal segments and regional LNs in inactive group (r = 0.448 to 0.595, all p<0.05). In logistic regression analyses, SOE0-30 and ADC value of regional LNs independently predicted active CD.Conclusion: Mesenteric LNs follow quantitative enhancement and diffusion parameters of bowel in active CD. SOE0-30 and ADC value of LN could predict disease activity.Key Points: • Mesenteric LNs may strongly follow enhancement pattern of bowel in active CD. • DWI parameters of LNs and bowel were strongly correlated in active CD. • SI180 was moderately correlated between bowel and LNs in inactive CD. • DWI parameters were moderately correlated between LNs and bowel in inactive CD. • SOE0-30 and ADC value of mesenteric LN could predict disease activity. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
Description
Abstract:<bold>Objectives: </bold>To demonstrate magnetic resonance enterography (MRE) features of mesenteric lymph nodes (LN) in patients with Crohn's disease (CD) and investigate whether they follow enhancement or apparent diffusion coefficient (ADC) parameters of bowel.<bold>Methods: </bold>This study was approved by the institutional review board. A total of 788 MREs from patients with CD were retrospectively reviewed. Eighty-eight patients, aged 16-66 years, including 59 active cases, were enrolled based on inclusion criteria. In each MRE, two segments (normal and abnormal) and two LNs (regional and non-regional) were independently suggested, consensually chosen, and analyzed by two radiologists. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated to assess signal intensities (SI) at 30, 60 and 180 s after contrast administration, as well as slope of enhancement (SOE). Enhancement parameters and ADC values were compared.<bold>Results: </bold>Regional LNs showed significantly higher SI30, SI60 and SI180 (CNR&SNR) and lower ADC values in active vs. inactive groups (all p<0.05) without significant difference in number or size. Strong correlations were demonstrated between abnormal segments and regional LNs in active group in terms of SI30, SI60, SI180, SOE0-30 and ADC values (r = 0.679 to 0.774, all p<0.001). SI180, SOE60-180 and ADC values were moderately correlated between abnormal segments and regional LNs in inactive group (r = 0.448 to 0.595, all p<0.05). In logistic regression analyses, SOE0-30 and ADC value of regional LNs independently predicted active CD.<bold>Conclusion: </bold>Mesenteric LNs follow quantitative enhancement and diffusion parameters of bowel in active CD. SOE0-30 and ADC value of LN could predict disease activity.<bold>Key Points: </bold>• Mesenteric LNs may strongly follow enhancement pattern of bowel in active CD. • DWI parameters of LNs and bowel were strongly correlated in active CD. • SI180 was moderately correlated between bowel and LNs in inactive CD. • DWI parameters were moderately correlated between LNs and bowel in inactive CD. • SOE0-30 and ADC value of mesenteric LN could predict disease activity. [ABSTRACT FROM AUTHOR]
ISSN:09387994
DOI:10.1007/s00330-018-5441-z