Corneal Endothelial Cell Segmentation by Classifier-Driven Merging of Oversegmented Images. |
| Authors: |
Vigueras-Guillen, Juan P., Andrinopoulou, Eleni-Rosalina, Engel, Angela, Lemij, Hans G., Van Rooij, Jeroen, Vermeer, Koenraad A., Van Vliet, Lucas J. |
| Source: |
IEEE Transactions on Medical Imaging. Oct2018, Vol. 37 Issue 10, p2278-2289. 12p. |
| Subjects: |
Specular microscopy, Support vector machines, Confocal microscopy, Endothelial cells, Polymorphism (Crystallography) |
| Abstract: |
Corneal endothelium images obtained by in vivo specular microscopy provide important information to assess the health status of the cornea. Estimation of clinical parameters, such as cell density, polymegethism, and pleomorphism, requires accurate cell segmentation. State-of-the-art techniques to automatically segment the endothelium are error-prone when applied to images with low contrast and/or large variation in cell size. Here, we propose an automatic method to segment the endothelium. Starting with an oversegmented image comprised of superpixels obtained from a stochastic watershed segmentation, the proposed method uses intensity and shape information of the superpixels to identify and merge those that constitute a cell, using support vector machines. We evaluated the automatic segmentation on a data set of in vivo specular microscopy images (Topcon SP-1P), obtaining 95.8% correctly merged cells and 2.0% undersegmented cells. We also evaluated the parameter estimation against the results of the vendor’s built-in software, obtaining a statistically significant better precision in all parameters and a similar or better accuracy. The parameter estimation was also evaluated on three other data sets from different imaging modalities (confocal microscopy, phase-contrast microscopy, and fluorescence confocal microscopy) and tissue types (ex vivo corneal endothelium and retinal pigment epithelium). In comparison with the estimates of the data sets’ authors, we achieved statistically significant better accuracy and precision in all parameters except pleomorphism, where a similar accuracy and precision were obtained. [ABSTRACT FROM AUTHOR] |
|
Copyright of IEEE Transactions on Medical Imaging is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
Engineering Source |