Investigation of long time constants of magnetic fields generated by the JT-60SA CS1 module.

Saved in:
Bibliographic Details
Title: Investigation of long time constants of magnetic fields generated by the JT-60SA CS1 module.
Authors: Obana, Tetsuhiro1 obana.tetsuhiro@nifs.ac.jp, Takahata, Kazuya1, Hamaguchi, Shinji1, Chikaraishi, Hirotaka1, Takada, Suguru1, Iwamoto, Akifumi1, Imagawa, Shinsaku1, Mito, Toshiyuki1, Murakami, Haruyuki2, Natsume, Kyohei2, Kizu, Kaname2
Source: Fusion Engineering & Design. Dec2018, Vol. 137, p274-282. 9p.
Subjects: Magnetic fields, Loop Current, Electrical conductors, Alloys, Coils (Magnetism)
Abstract: Highlights • Magnetic fields of the JT-60SA CS1 module were measured in a cold test. • The decay time constants of the magnetic field were from 90 s to 269 s after the CS1 module was degaussed. • Regarding the time constants, comparison between the JT-60SA CS model coil and the CS1 module was conducted. • The effect of the conductor ends on the time constants was investigated. Abstract In a cold test of the JT-60SA CS1 module, which is composed of six octa-pancake coils and one quad-pancake coil wound with Nb 3 Sn CIC conductors, the measurement of self-magnetic fields generated by the CS1 module was conducted. As a result, the decay of the self-magnetic field was observed after the CS1 module was degaussed. The time constant of the decay was from 90 s to 269 s. The measurement results indicate that loop currents with long time constants occurred in the CS1 module due to coil energization. The loop currents with long time constants, which are also called 'supercurrents', are irregular coupling currents that are an unexpected phenomenon from the conductor design. Loop currents with long time constants in CIC conductors have only been observed in large superconducting coils so far. To verify an occurrence of loop currents with long time constants in a CIC conductor without coil winding configuration, self-magnetic fields were measured using a short straight CIC conductor where a multi-strand cable was connected electrically at the conductor ends. As a result, loop currents with long time constants ranging from 57 s to 105 s occurred in the short straight CIC conductor, the length of which is approximately 1 m. The measurement results indicate that the conductor length is not always related to loop currents with long time constants. The occurrence of loop currents with long time constants in the CIC conductor depends on the presence of current paths at the conductor ends. [ABSTRACT FROM AUTHOR]
Copyright of Fusion Engineering & Design is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Highlights • Magnetic fields of the JT-60SA CS1 module were measured in a cold test. • The decay time constants of the magnetic field were from 90 s to 269 s after the CS1 module was degaussed. • Regarding the time constants, comparison between the JT-60SA CS model coil and the CS1 module was conducted. • The effect of the conductor ends on the time constants was investigated. Abstract In a cold test of the JT-60SA CS1 module, which is composed of six octa-pancake coils and one quad-pancake coil wound with Nb 3 Sn CIC conductors, the measurement of self-magnetic fields generated by the CS1 module was conducted. As a result, the decay of the self-magnetic field was observed after the CS1 module was degaussed. The time constant of the decay was from 90 s to 269 s. The measurement results indicate that loop currents with long time constants occurred in the CS1 module due to coil energization. The loop currents with long time constants, which are also called 'supercurrents', are irregular coupling currents that are an unexpected phenomenon from the conductor design. Loop currents with long time constants in CIC conductors have only been observed in large superconducting coils so far. To verify an occurrence of loop currents with long time constants in a CIC conductor without coil winding configuration, self-magnetic fields were measured using a short straight CIC conductor where a multi-strand cable was connected electrically at the conductor ends. As a result, loop currents with long time constants ranging from 57 s to 105 s occurred in the short straight CIC conductor, the length of which is approximately 1 m. The measurement results indicate that the conductor length is not always related to loop currents with long time constants. The occurrence of loop currents with long time constants in the CIC conductor depends on the presence of current paths at the conductor ends. [ABSTRACT FROM AUTHOR]
ISSN:09203796