Reduced Emissivity – A Factor for Precision in Pyrometric Measurements.

Saved in:
Bibliographic Details
Title: Reduced Emissivity – A Factor for Precision in Pyrometric Measurements.
Authors: Khodunkov, V. P.1 (AUTHOR) walkerearth@mail.ru
Source: Measurement Techniques. 2020, Vol. 62 Issue 12, p1035-1041. 7p.
Subjects: Emissivity, Pyrometers, Measurement, Heat radiation & absorption
Abstract: The problem of the precision of pyrometric measurements, associated with the convergence of readings of various pyrometers was examined. Readings in practice of pyrometric measurements of the overestimation of the measured temperature and a divergence of readings of various pyrometers are theoretically justified. One reason for the divergence of readings is the usage of an approximation calculation of the relationship for reduced emissivity in the equation of pyrometric measurement. The conditions for application of the specified equation are formulated. Calculation data of the effect of reduced emissivity on observed data are given, and practical recommendations for enhancing the precision of pyrometric measurements are made. [ABSTRACT FROM AUTHOR]
Copyright of Measurement Techniques is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 148390329
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Reduced Emissivity – A Factor for Precision in Pyrometric Measurements.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Khodunkov%2C+V%2E+P%2E%22">Khodunkov, V. P.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> walkerearth@mail.ru</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Measurement+Techniques%22">Measurement Techniques</searchLink>. 2020, Vol. 62 Issue 12, p1035-1041. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Emissivity%22">Emissivity</searchLink><br /><searchLink fieldCode="DE" term="%22Pyrometers%22">Pyrometers</searchLink><br /><searchLink fieldCode="DE" term="%22Measurement%22">Measurement</searchLink><br /><searchLink fieldCode="DE" term="%22Heat+radiation+%26+absorption%22">Heat radiation & absorption</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The problem of the precision of pyrometric measurements, associated with the convergence of readings of various pyrometers was examined. Readings in practice of pyrometric measurements of the overestimation of the measured temperature and a divergence of readings of various pyrometers are theoretically justified. One reason for the divergence of readings is the usage of an approximation calculation of the relationship for reduced emissivity in the equation of pyrometric measurement. The conditions for application of the specified equation are formulated. Calculation data of the effect of reduced emissivity on observed data are given, and practical recommendations for enhancing the precision of pyrometric measurements are made. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Measurement Techniques is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=148390329
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s11018-020-01731-1
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 1035
    Subjects:
      – SubjectFull: Emissivity
        Type: general
      – SubjectFull: Pyrometers
        Type: general
      – SubjectFull: Measurement
        Type: general
      – SubjectFull: Heat radiation & absorption
        Type: general
    Titles:
      – TitleFull: Reduced Emissivity – A Factor for Precision in Pyrometric Measurements.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Khodunkov, V. P.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: 2020
              Type: published
              Y: 2020
          Identifiers:
            – Type: issn-print
              Value: 05431972
          Numbering:
            – Type: volume
              Value: 62
            – Type: issue
              Value: 12
          Titles:
            – TitleFull: Measurement Techniques
              Type: main
ResultId 1