Quantitative dynamic near-infrared fluorescence imaging using indocyanine green for analysis of bowel perfusion after mesenteric resection.

Saved in:
Bibliographic Details
Title: Quantitative dynamic near-infrared fluorescence imaging using indocyanine green for analysis of bowel perfusion after mesenteric resection.
Authors: Meijer, Ruben P. J.1,2 (AUTHOR) R.P.J.meijer@lumc.nl, van Manen, Labrinus1 (AUTHOR) L.van_Manen@lumc.nl, Hartgrink, Henk H.1 (AUTHOR) h.h.hartgrink@lumc.nl, Burggraaf, Jacobus1,2 (AUTHOR) kb@chdr.nl, Gioux, Sylvain3 (AUTHOR) sylvain.gioux@intusurg.com, Vahrmeijer, Alexander L.1 (AUTHOR) a.l.vahrmeijer@lumc.nl, Mieog, J. Sven D.1 (AUTHOR) J.S.D.Mieog@lumc.nl
Source: Journal of Biomedical Optics. Jun2021, Vol. 26 Issue 6, p60501-60501. 1p.
Subjects: Indocyanine green, Fluorescence, Infrared imaging, Perfusion, Medical imaging systems, Treatment effectiveness
Abstract: Significance: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) has proven to be a feasible application for real-time intraoperative assessment of tissue perfusion, although quantification of NIR fluorescence signals is pivotal for standardized assessment of tissue perfusion. Aim: Four patients are described with possible compromised bowel perfusion after mesenteric resection. Based on these patients we want to emphasize the difficulties in the quantification of NIR fluorescence imaging for perfusion analysis. Approach: During image-guided fluorescence assessment, 5 mg of ICG (2.5 mg / ml) was intravenously administered by the anesthesiologist. NIR fluorescence imaging was done with the open camera system of Quest Medical Imaging. Fluorescence data taken from the regions of interest (bowel at risk, transition zone of bowel at risk and adjacent normally perfused bowel, and normally perfused reference bowel) were quantitatively analyzed after surgery for fluorescence intensity-and perfusion time-related parameters. Results: Bowel perfusion, as assessed clinically by independent surgeons based on NIR fluorescence imaging, resulted in different treatment strategies, three with excellent clinical outcome, but one with a perfusion related complication. Post-surgery quantitative analysis of fluorescence dynamics showed different patterns in the affected bowel segment compared to the unaffected reference segments for the four patients. Conclusions: Similar intraoperative fluorescence results could lead to different surgical treatment strategies, which demonstrated the difficulties in interpretation of uncorrected fluorescence signals. Real-time quantification and standardization of NIR fluorescence perfusion imaging could probably aid surgeons in the nearby future. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Biomedical Optics is the property of SPIE - International Society of Optical Engineering and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Significance: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) has proven to be a feasible application for real-time intraoperative assessment of tissue perfusion, although quantification of NIR fluorescence signals is pivotal for standardized assessment of tissue perfusion. Aim: Four patients are described with possible compromised bowel perfusion after mesenteric resection. Based on these patients we want to emphasize the difficulties in the quantification of NIR fluorescence imaging for perfusion analysis. Approach: During image-guided fluorescence assessment, 5 mg of ICG (2.5 mg / ml) was intravenously administered by the anesthesiologist. NIR fluorescence imaging was done with the open camera system of Quest Medical Imaging. Fluorescence data taken from the regions of interest (bowel at risk, transition zone of bowel at risk and adjacent normally perfused bowel, and normally perfused reference bowel) were quantitatively analyzed after surgery for fluorescence intensity-and perfusion time-related parameters. Results: Bowel perfusion, as assessed clinically by independent surgeons based on NIR fluorescence imaging, resulted in different treatment strategies, three with excellent clinical outcome, but one with a perfusion related complication. Post-surgery quantitative analysis of fluorescence dynamics showed different patterns in the affected bowel segment compared to the unaffected reference segments for the four patients. Conclusions: Similar intraoperative fluorescence results could lead to different surgical treatment strategies, which demonstrated the difficulties in interpretation of uncorrected fluorescence signals. Real-time quantification and standardization of NIR fluorescence perfusion imaging could probably aid surgeons in the nearby future. [ABSTRACT FROM AUTHOR]
ISSN:10833668
DOI:10.1117/1.JBO.26.6.060501