Stokes polarimetry-based second harmonic generation microscopy for collagen and skeletal muscle fiber characterization.

Saved in:
Bibliographic Details
Title: Stokes polarimetry-based second harmonic generation microscopy for collagen and skeletal muscle fiber characterization.
Authors: Mazumder, Nirmal1 nirmaluva@gmail.com, Kao, Fu-Jen2
Source: Lasers in Medical Science. Aug2021, Vol. 36 Issue 6, p1161-1167. 7p.
Subjects: Myosin, Second harmonic generation, Polarimetry, Collagen, Sarcomeres, Tumor microenvironment
Abstract: The complete polarization state of second harmonic (SH) light was measured and characterized by collagen type I and skeletal muscle fiber using a Stokes vector-based SHG microscope. The polarization states of the SH signal are analyzed in a pixel-by-pixel manner and displayed through two dimensional (2D) Stokes vector images. Various polarization parameters are reconstructed using Stokes values to quantify the polarization properties of SH light. Also, the measurements are extended for different input polarization states to investigate the molecular structure of second harmonic generation (SHG) active molecules such as collagen type I and myosin. [ABSTRACT FROM AUTHOR]
Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
Description
Abstract:The complete polarization state of second harmonic (SH) light was measured and characterized by collagen type I and skeletal muscle fiber using a Stokes vector-based SHG microscope. The polarization states of the SH signal are analyzed in a pixel-by-pixel manner and displayed through two dimensional (2D) Stokes vector images. Various polarization parameters are reconstructed using Stokes values to quantify the polarization properties of SH light. Also, the measurements are extended for different input polarization states to investigate the molecular structure of second harmonic generation (SHG) active molecules such as collagen type I and myosin. [ABSTRACT FROM AUTHOR]
ISSN:02688921
DOI:10.1007/s10103-020-03144-6