Bibliographic Details
| Title: |
New experimental measurement of nat Se(n, Îł) cross section between 1 eV to 1 keV at the CSNS Back-n facility. |
| Authors: |
Hu, Xin-Rong1,2 (AUTHOR), Liu, Long-Xiang3 (AUTHOR) liulongxiang@zjlab.org.cn, Jiang, Wei4,5 (AUTHOR), Ren, Jie6 (AUTHOR), Fan, Gong-Tao1,2,3 (AUTHOR) fangongtao@zjlab.org.cn, Wang, Hong-Wei1,2,3 (AUTHOR) wanghongwei@zjlab.org.cn, Cao, Xi-Guang1,3 (AUTHOR), Song, Long-Long3 (AUTHOR), Liu, Ying-Du7 (AUTHOR), Zhang, Yue4,5 (AUTHOR), Li, Xin-Xiang1,2 (AUTHOR), Hao, Zi-Rui1,2 (AUTHOR), Kuang, Pan1,2 (AUTHOR), Wang, Xiao-He1 (AUTHOR), Hu, Ji-Feng1 (AUTHOR), Jiang, Bing1,2 (AUTHOR), Wang, De-Xin8 (AUTHOR), Zhang, Suyalatu8 (AUTHOR), An, Zhen-Dong9 (AUTHOR), Wang, Yu-Ting10 (AUTHOR) |
| Source: |
Chinese Physics B. Aug2022, Vol. 31 Issue 8, p1-8. 8p. |
| Subjects: |
Neutron capture, Liquid scintillators, Nuclear astrophysics, Nuclear reactions, Neutron sources, Resonance |
| Geographic Terms: |
China |
| Abstract: |
The 74Se is one of 35 p-nuclei, and 82Se is a r-process only nucleus, and their (n, Îł) cross sections are vital input parameters for nuclear astrophysics reaction network calculations. The neutron capture cross section in the resonance range of isotopes and even natural selenium samples has not been measured. Prompt Îł -rays originating from neutron-induced capture events were detected by four C6D6 liquid scintillator detectors at the Back-n facility of China Spallation Neutron Source (CSNS). The pulse height weighting technique (PHWT) was used to analyze the data in the 1 eV to 100 keV region. The deduced neutron capture cross section was compared with ENDF/B-VIII.0, JEFF-3.2, and JENDL-4.0, and some differences were found. Resonance parameters were extracted by the R -matrix code SAMMY in the 1 eVâ€"1 keV region. All the cross sections of natSe and resonance parameters are given in the datasets. The datasets are openly available at http://www.doi.org/10.11922/sciencedb.j00113.00019. [ABSTRACT FROM AUTHOR] |
|
Copyright of Chinese Physics B is the property of IOP Publishing and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
Engineering Source |