Simultaneous determination of the HIV nucleoside analogue reverse transcriptase inhibitors lamivudine, didanosine, stavudine, zidovudine and abacavir in human plasma by reversed phase high performance liquid chromatography

Saved in:
Bibliographic Details
Title: Simultaneous determination of the HIV nucleoside analogue reverse transcriptase inhibitors lamivudine, didanosine, stavudine, zidovudine and abacavir in human plasma by reversed phase high performance liquid chromatography
Authors: Verweij-van Wissen, C.P.W.G.M.1,2 C.Verweij@akf.umcn.nl, Aarnoutse, R.E.1,2, Burger, D.M.1,2
Source: Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences. Feb2005, Vol. 816 Issue 1/2, p121-129. 9p.
Subjects: High performance liquid chromatography, Solid-phase analysis, Ultraviolet radiation, Nucleosides, Blood plasma
Abstract: Abstract: A reversed phase high performance liquid chromatography method was developed for the simultaneous quantitative determination of the nucleoside reverse transcriptase inhibitors (NRTIs) lamivudine, didanosine, stavudine, zidovudine and abacavir in plasma. The method involved solid-phase extraction with Oasis MAX cartridges from plasma, followed by high performance liquid chromatography with a SymmetryShield RP 18 column and ultraviolet detection set at a wavelength of 260nm. The assay was validated over the concentration range of 0.015–5mg/l for all five NRTIs. The average accuracies for the assay were 92–102%, inter- and intra-day coefficients of variation (CV) were <2.5% and extraction recoveries were higher than 97%. This method proved to be simple, accurate and precise, and is currently in use in our laboratory for the quantitative analysis of NRTIs in plasma. [Copyright &y& Elsevier]
Copyright of Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 16134182
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Simultaneous determination of the HIV nucleoside analogue reverse transcriptase inhibitors lamivudine, didanosine, stavudine, zidovudine and abacavir in human plasma by reversed phase high performance liquid chromatography
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Verweij-van+Wissen%2C+C%2EP%2EW%2EG%2EM%2E%22&quot;&gt;Verweij-van Wissen, C.P.W.G.M.&lt;/searchLink&gt;&lt;relatesTo&gt;1,2&lt;/relatesTo&gt;&lt;i&gt; C.Verweij@akf.umcn.nl&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Aarnoutse%2C+R%2EE%2E%22&quot;&gt;Aarnoutse, R.E.&lt;/searchLink&gt;&lt;relatesTo&gt;1,2&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Burger%2C+D%2EM%2E%22&quot;&gt;Burger, D.M.&lt;/searchLink&gt;&lt;relatesTo&gt;1,2&lt;/relatesTo&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Journal+of+Chromatography+B%3A+Analytical+Technologies+in+the+Biomedical+%26+Life+Sciences%22&quot;&gt;Journal of Chromatography B: Analytical Technologies in the Biomedical &amp; Life Sciences&lt;/searchLink&gt;. Feb2005, Vol. 816 Issue 1/2, p121-129. 9p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22High+performance+liquid+chromatography%22&quot;&gt;High performance liquid chromatography&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Solid-phase+analysis%22&quot;&gt;Solid-phase analysis&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Ultraviolet+radiation%22&quot;&gt;Ultraviolet radiation&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Nucleosides%22&quot;&gt;Nucleosides&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Blood+plasma%22&quot;&gt;Blood plasma&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Abstract: A reversed phase high performance liquid chromatography method was developed for the simultaneous quantitative determination of the nucleoside reverse transcriptase inhibitors (NRTIs) lamivudine, didanosine, stavudine, zidovudine and abacavir in plasma. The method involved solid-phase extraction with Oasis MAX cartridges from plasma, followed by high performance liquid chromatography with a SymmetryShield RP 18 column and ultraviolet detection set at a wavelength of 260nm. The assay was validated over the concentration range of 0.015–5mg/l for all five NRTIs. The average accuracies for the assay were 92–102%, inter- and intra-day coefficients of variation (CV) were &lt;2.5% and extraction recoveries were higher than 97%. This method proved to be simple, accurate and precise, and is currently in use in our laboratory for the quantitative analysis of NRTIs in plasma. [Copyright &amp;y&amp; Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Journal of Chromatography B: Analytical Technologies in the Biomedical &amp; Life Sciences is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=16134182
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.jchromb.2004.11.019
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 121
    Subjects:
      – SubjectFull: High performance liquid chromatography
        Type: general
      – SubjectFull: Solid-phase analysis
        Type: general
      – SubjectFull: Ultraviolet radiation
        Type: general
      – SubjectFull: Nucleosides
        Type: general
      – SubjectFull: Blood plasma
        Type: general
    Titles:
      – TitleFull: Simultaneous determination of the HIV nucleoside analogue reverse transcriptase inhibitors lamivudine, didanosine, stavudine, zidovudine and abacavir in human plasma by reversed phase high performance liquid chromatography
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Verweij-van Wissen, C.P.W.G.M.
      – PersonEntity:
          Name:
            NameFull: Aarnoutse, R.E.
      – PersonEntity:
          Name:
            NameFull: Burger, D.M.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 25
              M: 02
              Text: Feb2005
              Type: published
              Y: 2005
          Identifiers:
            – Type: issn-print
              Value: 15700232
          Numbering:
            – Type: volume
              Value: 816
            – Type: issue
              Value: 1/2
          Titles:
            – TitleFull: Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences
              Type: main
ResultId 1