Pressure Drop in Seven-Pin Wire-Wrapped Rod Bundle for the Sodium Cartridge Loop in Versatile Test Reactor.

Saved in:
Bibliographic Details
Title: Pressure Drop in Seven-Pin Wire-Wrapped Rod Bundle for the Sodium Cartridge Loop in Versatile Test Reactor.
Authors: Quan, Zhengting1 (AUTHOR), Dix, Adam1 (AUTHOR), Kong, Ran1 (AUTHOR), Kim, Seungjin1 (AUTHOR) seungjin@purdue.edu, Ishii, Mamoru1 (AUTHOR), Farmer, Mitchell T.2 (AUTHOR)
Source: Nuclear Science & Engineering. May2023, Vol. 197 Issue 5, p771-787. 17p.
Subjects: Pressure drop (Fluid dynamics), Computational fluid dynamics, Fast reactors, Reynolds number, Sodium, Shearing force
Abstract: This work studies the hydrodynamics of the seven-pin wire-wrapped rod bundle in the sodium cartridge loop for the Versatile Test Reactor (VTR) through scaled water experiments and computational fluid dynamics (CFD) simulations. The scaling analysis is first performed to demonstrate the hydrodynamic similarity between water and sodium flows at the same Reynolds number R e. A separate-effects test facility is designed and constructed based on the scaling analysis. Detailed experimental data on the pressure drop covering a wide range of R e values (1165 to 27 689) are obtained, which are used to evaluate existing correlations for friction factor and to benchmark CFD simulations. The experimentally determined friction factors f E x p agree well with the Upgraded Cheng and Todreas Detailed Correlation and Pacio-Chen-Todreas Detailed Model within ± 7 % but are significantly underpredicted by Rehme's correlation by 25%. Various CFD near-wall treatment methods are tested using ANSYS Fluent and evaluated by experimental data. It is found that when the recommended wall y + values are met, most of the near-wall treatment methods can give accurate friction factor predictions. The resolved near-wall method ( y + ∼ 1) with the Shear Stress Transport k − ω turbulence model and the scalable wall functions ( y + > 12) with the realizable k − ε turbulence model can predict f E x p within ± 5 % . The standard wall functions ( y + > 30) and nonequilibrium wall functions ( y + > 30) with the realizable k − ε model can predict f E x p within ± 10%. [ABSTRACT FROM AUTHOR]
Copyright of Nuclear Science & Engineering is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:This work studies the hydrodynamics of the seven-pin wire-wrapped rod bundle in the sodium cartridge loop for the Versatile Test Reactor (VTR) through scaled water experiments and computational fluid dynamics (CFD) simulations. The scaling analysis is first performed to demonstrate the hydrodynamic similarity between water and sodium flows at the same Reynolds number R e. A separate-effects test facility is designed and constructed based on the scaling analysis. Detailed experimental data on the pressure drop covering a wide range of R e values (1165 to 27 689) are obtained, which are used to evaluate existing correlations for friction factor and to benchmark CFD simulations. The experimentally determined friction factors f E x p agree well with the Upgraded Cheng and Todreas Detailed Correlation and Pacio-Chen-Todreas Detailed Model within ± 7 % but are significantly underpredicted by Rehme's correlation by 25%. Various CFD near-wall treatment methods are tested using ANSYS Fluent and evaluated by experimental data. It is found that when the recommended wall y + values are met, most of the near-wall treatment methods can give accurate friction factor predictions. The resolved near-wall method ( y + ∼ 1) with the Shear Stress Transport k − ω turbulence model and the scalable wall functions ( y + > 12) with the realizable k − ε turbulence model can predict f E x p within ± 5 % . The standard wall functions ( y + > 30) and nonequilibrium wall functions ( y + > 30) with the realizable k − ε model can predict f E x p within ± 10%. [ABSTRACT FROM AUTHOR]
ISSN:00295639
DOI:10.1080/00295639.2022.2082232