Enhanced 129Xe T1 relaxation in whole blood and in the presence of SPIONs at low magnetic field strengths.

Saved in:
Bibliographic Details
Title: Enhanced 129Xe T1 relaxation in whole blood and in the presence of SPIONs at low magnetic field strengths.
Authors: Bryden, Nicholas1,2 (AUTHOR), Atalla, Sebastian W.1,2 (AUTHOR), Kelley, Michele1,2 (AUTHOR), Holmes, Leah R.1,2 (AUTHOR), Branca, Rosa T.1,2 (AUTHOR) rtbranca@unc.edu
Source: Magnetic Resonance in Medicine. Jul2023, Vol. 90 Issue 1, p21-33. 13p.
Subjects: Magnetic flux density, Iron oxide nanoparticles, Spectral imaging, Xenon
Abstract: Purpose: To compare the effect of superparamagnetic iron oxide nanoparticles (SPIONs) on the T1 of 129Xe and 1H and to measure the relaxation of 129Xe in blood at low and high magnetic field strengths. Methods: 129Xe and 1H T1 relaxometry was performed at low‐ and high‐field strengths in samples containing different SPION concentrations, while imaging was used to compare the contrast obtainable in these two field regimes. In vivo experiments at variable field strengths were performed to determine the depolarization of 129Xe in blood and the feasibility of in vivo dissolved‐phase spectroscopy and imaging at low field. Results: The SPION relaxivity was substantially greater at low field for 1H, increasing from 0.92 ± 0.06 mM s−1 at 11.7T to 31.5 ± 1.8 mM s−1 at 0.6 mT, and for 129Xe, which increased from 0.13 ± 0.03 mM s−1 at 11.7T to 7.32 ± 0.71 mM s−1 at 2.1 mT. The additional MR signal loss increased from 0.7% at 9.4T to 20.6 ± 4.2% at 0.6 mT for 1H and from −0.7 ± 3.4% at 9.4T to 12.7 ± 3.5% at 2.1 mT for 129Xe. Blood was found to depolarize 129Xe below 3T in a manner inversely proportional to the field strength. In vitro studies at 2.1 mT suggest 129Xe relaxation times below 5 s in blood dilutions as low as 0.4% volume. Conclusion: SPIONs longitudinal relaxivity increases at low field both for 1H and 129Xe. The depolarization of xenon in blood, which is found to increase below 3T, effectively prevents in vivo dissolved‐phase spectroscopy and imaging at low‐field strengths. [ABSTRACT FROM AUTHOR]
Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
Description
Abstract:Purpose: To compare the effect of superparamagnetic iron oxide nanoparticles (SPIONs) on the T1 of 129Xe and 1H and to measure the relaxation of 129Xe in blood at low and high magnetic field strengths. Methods: 129Xe and 1H T1 relaxometry was performed at low‐ and high‐field strengths in samples containing different SPION concentrations, while imaging was used to compare the contrast obtainable in these two field regimes. In vivo experiments at variable field strengths were performed to determine the depolarization of 129Xe in blood and the feasibility of in vivo dissolved‐phase spectroscopy and imaging at low field. Results: The SPION relaxivity was substantially greater at low field for 1H, increasing from 0.92 ± 0.06 mM s−1 at 11.7T to 31.5 ± 1.8 mM s−1 at 0.6 mT, and for 129Xe, which increased from 0.13 ± 0.03 mM s−1 at 11.7T to 7.32 ± 0.71 mM s−1 at 2.1 mT. The additional MR signal loss increased from 0.7% at 9.4T to 20.6 ± 4.2% at 0.6 mT for 1H and from −0.7 ± 3.4% at 9.4T to 12.7 ± 3.5% at 2.1 mT for 129Xe. Blood was found to depolarize 129Xe below 3T in a manner inversely proportional to the field strength. In vitro studies at 2.1 mT suggest 129Xe relaxation times below 5 s in blood dilutions as low as 0.4% volume. Conclusion: SPIONs longitudinal relaxivity increases at low field both for 1H and 129Xe. The depolarization of xenon in blood, which is found to increase below 3T, effectively prevents in vivo dissolved‐phase spectroscopy and imaging at low‐field strengths. [ABSTRACT FROM AUTHOR]
ISSN:07403194
DOI:10.1002/mrm.29619