Influence of device-assisted suction against resistance (Mueller maneuver) on image quality in CTPA for suspected lung embolism.
Saved in:
| Title: | Influence of device-assisted suction against resistance (Mueller maneuver) on image quality in CTPA for suspected lung embolism. |
|---|---|
| Authors: | von Münchhausen, Niklas1 (AUTHOR), Janssen, Sonja1 (AUTHOR), Overhoff, Daniel1,2 (AUTHOR), Rink, Johann S.1 (AUTHOR), Geurts, Bram3 (AUTHOR), Gutzeit, Andreas4,5 (AUTHOR), Prokop, Mathias3 (AUTHOR), Schoenberg, Stefan O.1 (AUTHOR), Froelich, Matthias F.1 (AUTHOR) Matthias.Froelich@medma.uni-heidelberg.de |
| Source: | European Radiology. Nov2023, Vol. 33 Issue 11, p7840-7848. 9p. |
| Subjects: | Medical personnel, Thoracic aorta, Pulmonary artery, Pulmonary embolism, Embolisms, Breathing exercises, Medical artifacts |
| Abstract: | Objectives: To investigate the effect of a device-assisted suction against resistance Mueller maneuver (MM) on transient interruption of contrast (TIC) in the aorta and pulmonary trunk (PT) on computed tomography pulmonary angiogram (CTPA). Methods: In this prospective single-center study, 150 patients with suspected pulmonary artery embolism were assigned randomly with two different breathing maneuvers (Mueller maneuver (MM) or standard end-inspiratory breath-hold command (SBC)) during routine CTPA. The MM was performed using a patented prototype (Contrast Booster™) which allows both the patient by means of visual feedback and the medical staff in the CT scanning room to monitor whether the patient is sucking sufficiently or not. Mean Hounsfield attenuation in descending aorta and PT was measured and compared. Results: Overall, patients with MM showed an attenuation of 338.24 HU in the pulmonary trunk, compared to 313.71 HU in SBC (p = 0.157). In the aorta, the values for MM were lower compared to SBC (134.42 HU vs. 177.83 HU, p = 0.001). The TP-aortic ratio was significantly higher in the MM group at 3.86 compared to the SBC group at 2.26, p = 0.001. TIC phenomenon was absent in the MM group, whereas it was present in 9 patients (12.3%) in the SBC group (p = 0.005). Overall contrast was better on all levels for MM (p < 0.001). The presence of breathing artifacts was higher in the MM group (48.1% vs. 30.1%, p = 0.038), without clinical consequence. Conclusions: Performing the MM with the application of the prototype is an effective way of preventing the TIC phenomenon during i.v. contrast-enhanced CTPA scanning compared to the standard end-inspiratory breathing command. Clinical relevance: Compared to standard end-inspiratory breathing command, the device-assisted Mueller maneuver (MM) improves contrast enhancement and prevents the transient interruption of contrast (TIC) phenomenon in CTPA. Therefore, it may offer optimized diagnostic workup and timely treatment for patients with pulmonary embolism. Key Points: • Transient interruption of contrast (TIC) may impair image quality in CTPA. • Mueller Maneuver using a device prototype could lower the rate of TIC. • Device application in clinical routine may increase diagnostic accuracy. [ABSTRACT FROM AUTHOR] |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | Objectives: To investigate the effect of a device-assisted suction against resistance Mueller maneuver (MM) on transient interruption of contrast (TIC) in the aorta and pulmonary trunk (PT) on computed tomography pulmonary angiogram (CTPA). Methods: In this prospective single-center study, 150 patients with suspected pulmonary artery embolism were assigned randomly with two different breathing maneuvers (Mueller maneuver (MM) or standard end-inspiratory breath-hold command (SBC)) during routine CTPA. The MM was performed using a patented prototype (Contrast Booster™) which allows both the patient by means of visual feedback and the medical staff in the CT scanning room to monitor whether the patient is sucking sufficiently or not. Mean Hounsfield attenuation in descending aorta and PT was measured and compared. Results: Overall, patients with MM showed an attenuation of 338.24 HU in the pulmonary trunk, compared to 313.71 HU in SBC (p = 0.157). In the aorta, the values for MM were lower compared to SBC (134.42 HU vs. 177.83 HU, p = 0.001). The TP-aortic ratio was significantly higher in the MM group at 3.86 compared to the SBC group at 2.26, p = 0.001. TIC phenomenon was absent in the MM group, whereas it was present in 9 patients (12.3%) in the SBC group (p = 0.005). Overall contrast was better on all levels for MM (p < 0.001). The presence of breathing artifacts was higher in the MM group (48.1% vs. 30.1%, p = 0.038), without clinical consequence. Conclusions: Performing the MM with the application of the prototype is an effective way of preventing the TIC phenomenon during i.v. contrast-enhanced CTPA scanning compared to the standard end-inspiratory breathing command. Clinical relevance: Compared to standard end-inspiratory breathing command, the device-assisted Mueller maneuver (MM) improves contrast enhancement and prevents the transient interruption of contrast (TIC) phenomenon in CTPA. Therefore, it may offer optimized diagnostic workup and timely treatment for patients with pulmonary embolism. Key Points: • Transient interruption of contrast (TIC) may impair image quality in CTPA. • Mueller Maneuver using a device prototype could lower the rate of TIC. • Device application in clinical routine may increase diagnostic accuracy. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 09387994 |
| DOI: | 10.1007/s00330-023-09834-3 |