Development of a standalone delivery sequence model for proton arc therapy.

Saved in:
Bibliographic Details
Title: Development of a standalone delivery sequence model for proton arc therapy.
Authors: Liu, Gang1,2,3 (AUTHOR) liugang9910@163.com, Zhao, Lewei4 (AUTHOR), Liu, Peilin5 (AUTHOR), Yan, Di5 (AUTHOR), Deraniyagala, Rohan5 (AUTHOR), Stevens, Craig5 (AUTHOR), Li, Xiaoqiang5 (AUTHOR), Ding, Xuanfeng5 (AUTHOR) xuanfengding@gmail.com
Source: Medical Physics. Apr2024, Vol. 51 Issue 4, p3067-3075. 9p.
Subjects: Proton therapy, Medical research personnel, Electric arc, Proton beams, Inclinometer, Test methods
Abstract: Background: Spot‐scanning proton arc (SPArc) has been drawing significant interests in recent years because of its capability of continuous proton irradiation during the gantry rotation. Previous studies demonstrated SPArc plans were delivered on a prototype of the DynamicARC solution, IBA ProteusONE. Purpose: We built a novel delivery sequence model through an independent experimental approach: the first SPArc delivery sequence model (DSMSPArc). Based on the model, we investigated SPArc treatment efficiency improvement in the routine proton clinical operation. Methods: SPArc test plans were generated and delivered on a prototype of the DynamicARC solution, IBA ProteusONE. An independent gantry inclinometer and the machine logfiles were used to derive the DSMSPArc. Seventeen SPArc plans were used to validate the model's accuracy independently. Two random clinical operation dates (6th January and 22nd March, 2021) from a single‐room proton therapy center (PTC) were selected to quantitatively assess the improvement of treatment efficiency compared to the IMPT. Results: The difference between the logfile and DSMSPArc is about 3.2 ± 4.8%. SPArc reduced 58.1% of the average treatment delivery time per patient compared to IMPT (p < 0.01). Daily treatment throughput could be increased by 30% using SPArc using a single‐room proton therapy system. Conclusions: The first model of dynamic arc therapy is established in this study through an independent experimental approach using logfiles and measurements which allows clinical users and investigators to simulate the dynamic treatment delivery and assess the daily treatment throughput improvement. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 176451116
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Development of a standalone delivery sequence model for proton arc therapy.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Liu%2C+Gang%22&quot;&gt;Liu, Gang&lt;/searchLink&gt;&lt;relatesTo&gt;1,2,3&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; liugang9910@163.com&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Zhao%2C+Lewei%22&quot;&gt;Zhao, Lewei&lt;/searchLink&gt;&lt;relatesTo&gt;4&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Liu%2C+Peilin%22&quot;&gt;Liu, Peilin&lt;/searchLink&gt;&lt;relatesTo&gt;5&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Yan%2C+Di%22&quot;&gt;Yan, Di&lt;/searchLink&gt;&lt;relatesTo&gt;5&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Deraniyagala%2C+Rohan%22&quot;&gt;Deraniyagala, Rohan&lt;/searchLink&gt;&lt;relatesTo&gt;5&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Stevens%2C+Craig%22&quot;&gt;Stevens, Craig&lt;/searchLink&gt;&lt;relatesTo&gt;5&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Li%2C+Xiaoqiang%22&quot;&gt;Li, Xiaoqiang&lt;/searchLink&gt;&lt;relatesTo&gt;5&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Ding%2C+Xuanfeng%22&quot;&gt;Ding, Xuanfeng&lt;/searchLink&gt;&lt;relatesTo&gt;5&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; xuanfengding@gmail.com&lt;/i&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Medical+Physics%22&quot;&gt;Medical Physics&lt;/searchLink&gt;. Apr2024, Vol. 51 Issue 4, p3067-3075. 9p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Proton+therapy%22&quot;&gt;Proton therapy&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Medical+research+personnel%22&quot;&gt;Medical research personnel&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Electric+arc%22&quot;&gt;Electric arc&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Proton+beams%22&quot;&gt;Proton beams&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Inclinometer%22&quot;&gt;Inclinometer&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Test+methods%22&quot;&gt;Test methods&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: Spot‐scanning proton arc (SPArc) has been drawing significant interests in recent years because of its capability of continuous proton irradiation during the gantry rotation. Previous studies demonstrated SPArc plans were delivered on a prototype of the DynamicARC solution, IBA ProteusONE. Purpose: We built a novel delivery sequence model through an independent experimental approach: the first SPArc delivery sequence model (DSMSPArc). Based on the model, we investigated SPArc treatment efficiency improvement in the routine proton clinical operation. Methods: SPArc test plans were generated and delivered on a prototype of the DynamicARC solution, IBA ProteusONE. An independent gantry inclinometer and the machine logfiles were used to derive the DSMSPArc. Seventeen SPArc plans were used to validate the model&#39;s accuracy independently. Two random clinical operation dates (6th January and 22nd March, 2021) from a single‐room proton therapy center (PTC) were selected to quantitatively assess the improvement of treatment efficiency compared to the IMPT. Results: The difference between the logfile and DSMSPArc is about 3.2 &#177; 4.8%. SPArc reduced 58.1% of the average treatment delivery time per patient compared to IMPT (p &lt; 0.01). Daily treatment throughput could be increased by 30% using SPArc using a single‐room proton therapy system. Conclusions: The first model of dynamic arc therapy is established in this study through an independent experimental approach using logfiles and measurements which allows clinical users and investigators to simulate the dynamic treatment delivery and assess the daily treatment throughput improvement. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=176451116
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.16879
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 3067
    Subjects:
      – SubjectFull: Proton therapy
        Type: general
      – SubjectFull: Medical research personnel
        Type: general
      – SubjectFull: Electric arc
        Type: general
      – SubjectFull: Proton beams
        Type: general
      – SubjectFull: Inclinometer
        Type: general
      – SubjectFull: Test methods
        Type: general
    Titles:
      – TitleFull: Development of a standalone delivery sequence model for proton arc therapy.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Liu, Gang
      – PersonEntity:
          Name:
            NameFull: Zhao, Lewei
      – PersonEntity:
          Name:
            NameFull: Liu, Peilin
      – PersonEntity:
          Name:
            NameFull: Yan, Di
      – PersonEntity:
          Name:
            NameFull: Deraniyagala, Rohan
      – PersonEntity:
          Name:
            NameFull: Stevens, Craig
      – PersonEntity:
          Name:
            NameFull: Li, Xiaoqiang
      – PersonEntity:
          Name:
            NameFull: Ding, Xuanfeng
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 51
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1