Experimental study on the compressive behavior of UHPC filled stainless steel tubes subjected to monotonic and cyclic loading.

Saved in:
Bibliographic Details
Title: Experimental study on the compressive behavior of UHPC filled stainless steel tubes subjected to monotonic and cyclic loading.
Authors: Lai, Bing-Lin1,2 (AUTHOR) bl_lai@seu.edu.cn, Li, Yi-Ran1 (AUTHOR), Jin, Liu2 (AUTHOR), Fan, Sheng-Gang1 (AUTHOR)
Source: Construction & Building Materials. Oct2024, Vol. 449, pN.PAG-N.PAG. 1p.
Subjects: Cyclic loads, Axial loads, Steel tubes, Compression loads, Failure mode & effects analysis
Abstract: Ultra-High Performance Concrete Filled Stainless Steel Tubular (UHPCFSST) column is a novel type of composite columns appealing to be adopted in corrosive and marine environment. To explore the axial performance of UHPCFSST columns, this paper initiates an experimental program containing 14 UHPCFSST columns subjected to either monotonic or cyclical axial compressive loading. The test variables in this program mainly include the column dimension, tube thickness and the loading schemes. Based on the test results, the damage evolution process, ultimate failure mode, load-deformation response and the typical mechanical performance indexes inclusive of loading-carrying capacity, stiffness degradation, as well as ductility coefficient are thoroughly examined. After that, theoretical analysis is carried out to explore the interaction behavior between UHPC and stainless-steel tube and hence judge the degree of confinement effect. To assess the applicability of the code equations stipulated in current international design guidelines and the empirical formulas proposed by other researchers, a small-scale dataset containing 41 UHPCFSST columns was compiled to make comparison of axial capacity between test results and analytical predictions. In view of the limited accuracy or the burdensome calculation process, a new formula considering actual loading carrying mechanism was proposed to calculate the axial capacity of UHPCFSST columns, which exhibits enhanced accuracy and efficiency than the current formulas. • 14 UHPCFSST columns were test under monotonic or cyclic axial loading. • The failure mode and performance indexes UHPCFSST columns were analyzed. • The confinement effect of UHPCFSST columns were discussed. • The prediction performance of current design formulas was evaluated. [ABSTRACT FROM AUTHOR]
Copyright of Construction & Building Materials is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Ultra-High Performance Concrete Filled Stainless Steel Tubular (UHPCFSST) column is a novel type of composite columns appealing to be adopted in corrosive and marine environment. To explore the axial performance of UHPCFSST columns, this paper initiates an experimental program containing 14 UHPCFSST columns subjected to either monotonic or cyclical axial compressive loading. The test variables in this program mainly include the column dimension, tube thickness and the loading schemes. Based on the test results, the damage evolution process, ultimate failure mode, load-deformation response and the typical mechanical performance indexes inclusive of loading-carrying capacity, stiffness degradation, as well as ductility coefficient are thoroughly examined. After that, theoretical analysis is carried out to explore the interaction behavior between UHPC and stainless-steel tube and hence judge the degree of confinement effect. To assess the applicability of the code equations stipulated in current international design guidelines and the empirical formulas proposed by other researchers, a small-scale dataset containing 41 UHPCFSST columns was compiled to make comparison of axial capacity between test results and analytical predictions. In view of the limited accuracy or the burdensome calculation process, a new formula considering actual loading carrying mechanism was proposed to calculate the axial capacity of UHPCFSST columns, which exhibits enhanced accuracy and efficiency than the current formulas. • 14 UHPCFSST columns were test under monotonic or cyclic axial loading. • The failure mode and performance indexes UHPCFSST columns were analyzed. • The confinement effect of UHPCFSST columns were discussed. • The prediction performance of current design formulas was evaluated. [ABSTRACT FROM AUTHOR]
ISSN:09500618
DOI:10.1016/j.conbuildmat.2024.138301