Radiomic feature robustness in CT scans affected by fiducial marker induced streak artifacts for patients with hepatocellular carcinoma.

Saved in:
Bibliographic Details
Title: Radiomic feature robustness in CT scans affected by fiducial marker induced streak artifacts for patients with hepatocellular carcinoma.
Authors: Verstappen, Damon1 (AUTHOR) damon.verstappen@maastrichtuniversity.nl, Pasquier, David1,2,3 (AUTHOR), Chen, Yi1 (AUTHOR), Lambin, Phillipe1,4 (AUTHOR), Woodruff, Henry C.1,4 (AUTHOR)
Source: Medical Physics. Nov2024, Vol. 51 Issue 11, p8362-8370. 9p.
Subjects: Stereotactic radiotherapy, Computed tomography, Hepatocellular carcinoma, Radiomics, Zone melting
Abstract: Background: Stereotactic body radiation therapy for hepatocellular carcinoma necessitates the implantation of gold fiducial markers in the liver, resulting in artifacts on computed tomography (CT) scans, which affect radiomic feature values. Purpose: This report aims to assess the effect of these artifacts on radiomic features and how removing CT slices affects radiomic features extracted from 3D regions of interest (ROI). Methods: First, the range variation in 38 tumor contours unaffected by artifacts was assessed after sequentially and randomly removing 25%, 50%, 75% of slices. Subsequently, the agreement of feature values before and after removing ROI slices containing artifacts from 186 patients' CT scans was assessed with Lin's concordance correlation coefficient (CCC) and a Wilcoxon signed‐rank test. Results: In artifact‐free tumor volumes, at least 71% of features remain robust with up to 50% of slices removed, while 56% remains robust with up to 75% of slices removed. When comparing contours before and after removing slices containing artifacts, around a third of features in the tumor contour and surrounding area remain robust (CCC > 0.9), compared to 44% in the healthy liver. Concerning the tumor, 13% (Gray Level Size Zone Matrix) to 61% (first order) of the features remain robust (CCC > 0.9). Over 90% of features differ significantly as assessed by Wilcoxon signed‐rank test, however. Conclusions: This study demonstrates that removing slices containing artifacts is a feasible solution for the CT fiducial problem in this patient population and provides insight into which features are affected. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 180622921
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Radiomic feature robustness in CT scans affected by fiducial marker induced streak artifacts for patients with hepatocellular carcinoma.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Verstappen%2C+Damon%22">Verstappen, Damon</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> damon.verstappen@maastrichtuniversity.nl</i><br /><searchLink fieldCode="AR" term="%22Pasquier%2C+David%22">Pasquier, David</searchLink><relatesTo>1,2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Chen%2C+Yi%22">Chen, Yi</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lambin%2C+Phillipe%22">Lambin, Phillipe</searchLink><relatesTo>1,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Woodruff%2C+Henry+C%2E%22">Woodruff, Henry C.</searchLink><relatesTo>1,4</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Nov2024, Vol. 51 Issue 11, p8362-8370. 9p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Stereotactic+radiotherapy%22">Stereotactic radiotherapy</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Hepatocellular+carcinoma%22">Hepatocellular carcinoma</searchLink><br /><searchLink fieldCode="DE" term="%22Radiomics%22">Radiomics</searchLink><br /><searchLink fieldCode="DE" term="%22Zone+melting%22">Zone melting</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: Stereotactic body radiation therapy for hepatocellular carcinoma necessitates the implantation of gold fiducial markers in the liver, resulting in artifacts on computed tomography (CT) scans, which affect radiomic feature values. Purpose: This report aims to assess the effect of these artifacts on radiomic features and how removing CT slices affects radiomic features extracted from 3D regions of interest (ROI). Methods: First, the range variation in 38 tumor contours unaffected by artifacts was assessed after sequentially and randomly removing 25%, 50%, 75% of slices. Subsequently, the agreement of feature values before and after removing ROI slices containing artifacts from 186 patients' CT scans was assessed with Lin's concordance correlation coefficient (CCC) and a Wilcoxon signed‐rank test. Results: In artifact‐free tumor volumes, at least 71% of features remain robust with up to 50% of slices removed, while 56% remains robust with up to 75% of slices removed. When comparing contours before and after removing slices containing artifacts, around a third of features in the tumor contour and surrounding area remain robust (CCC > 0.9), compared to 44% in the healthy liver. Concerning the tumor, 13% (Gray Level Size Zone Matrix) to 61% (first order) of the features remain robust (CCC > 0.9). Over 90% of features differ significantly as assessed by Wilcoxon signed‐rank test, however. Conclusions: This study demonstrates that removing slices containing artifacts is a feasible solution for the CT fiducial problem in this patient population and provides insight into which features are affected. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=180622921
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.17329
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 8362
    Subjects:
      – SubjectFull: Stereotactic radiotherapy
        Type: general
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: Hepatocellular carcinoma
        Type: general
      – SubjectFull: Radiomics
        Type: general
      – SubjectFull: Zone melting
        Type: general
    Titles:
      – TitleFull: Radiomic feature robustness in CT scans affected by fiducial marker induced streak artifacts for patients with hepatocellular carcinoma.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Verstappen, Damon
      – PersonEntity:
          Name:
            NameFull: Pasquier, David
      – PersonEntity:
          Name:
            NameFull: Chen, Yi
      – PersonEntity:
          Name:
            NameFull: Lambin, Phillipe
      – PersonEntity:
          Name:
            NameFull: Woodruff, Henry C.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 51
            – Type: issue
              Value: 11
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1