Status of Work on Creating Carbon Ion Beam Channels for Radiobiological and Preclinical Studies at the U-70 Accelerator Complex.
Saved in:
| Title: | Status of Work on Creating Carbon Ion Beam Channels for Radiobiological and Preclinical Studies at the U-70 Accelerator Complex. |
|---|---|
| Authors: | Garkusha, V. I.1 (AUTHOR) Valeriy.Garkusha@ihep.ru, Ivanov, S. V.1 (AUTHOR), Kalinin, V. A.1 (AUTHOR), Maksimov, A. V.1 (AUTHOR), Markin, A. M.1 (AUTHOR), Novoskol'tsev, F. N.1 (AUTHOR), Pikalov, V. A.1 (AUTHOR), Soldatov, A. P.1 (AUTHOR), Sinyukov, R. Yu.1 (AUTHOR) rspro@ihep.ru |
| Source: | Instruments & Experimental Techniques. 2024 Suppl 2, Vol. 67, pS236-S241. 6p. |
| Subjects: | Ion accelerators, Physical sciences, Particles (Nuclear physics), Ion channels, Magnets, Ion beams |
| Abstract: | An optical scheme of the channel for transporting 12C+6 carbon ion beams to the radiobiological research area is presented. The results of deceleration of carbon ions in the accelerator U-70 from 455 to 200 MeV/nucleon and beam output from U-70 are presented. The scheme of uniform dose field formation by means of vertical and horizontal wobbler magnets is considered. Plans for the development of ion-beam therapy channels at the IHEP accelerator complex are given. [ABSTRACT FROM AUTHOR] |
| Copyright of Instruments & Experimental Techniques is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | An optical scheme of the channel for transporting 12C+6 carbon ion beams to the radiobiological research area is presented. The results of deceleration of carbon ions in the accelerator U-70 from 455 to 200 MeV/nucleon and beam output from U-70 are presented. The scheme of uniform dose field formation by means of vertical and horizontal wobbler magnets is considered. Plans for the development of ion-beam therapy channels at the IHEP accelerator complex are given. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 00204412 |
| DOI: | 10.1134/S0020441224701768 |