Parametric analysis of design and operating conditions for energy and particulate matter separation in vortex tubes.

Saved in:
Bibliographic Details
Title: Parametric analysis of design and operating conditions for energy and particulate matter separation in vortex tubes.
Authors: Hyun, Su Woong1 (AUTHOR), Kim, Gun Woo2 (AUTHOR), Kim, Young-Shik2 (AUTHOR), Kim, Hyun-Seok2 (AUTHOR), Shin, Dong Ho3 (AUTHOR) shindh@dgu.ac.kr
Source: Separation Science & Technology. 2025, Vol. 60 Issue 18, p2767-2785. 19p.
Subjects: Vortex tubes, Particulate matter, Computational fluid dynamics, Separation (Technology), Dust removal, Conservation of energy
Abstract: The vortex tube (VT) is a device known for separating a compressed gas stream into hot and cold fractions. This study numerically investigates its dual potential for thermal separation and particulate matter (PM) removal. Using computational fluid dynamics, the effects of key design parameters and operating conditions on separation performance are analyzed for uniflow and counterflow vortex tubes. The investigated variables include tube diameter, inlet pressure, particle size (0.05 to 10 µm), and gas injection angle. The thermal analysis reveals a strong dependence of temperature separation (ΔT) on inlet pressure and diameter, with combinations of low pressure and large diameters yielding the highest ΔT, in the range of 60 to 70°C. The PM analysis shows that efficiency is governed by a coupled set of variables. Particle size is the dominant factor, with particles larger than 1 µm achieving over 99% removal efficiency. Inlet pressure has a diameter dependent effect; its increase significantly reduces efficiency in large diameter tubes but has a negligible impact in smaller tubes. A larger gas injection angle monotonically increases PM separation by strengthening tangential momentum. Coordinated selection of diameter, inlet pressure, and injection angle enables application specific tuning for simultaneous energy and particulate separation. HIGHLIGHT: A comparison between the counterflow and uniflow types of VTs was carried out. Temperature difference between the cold and hot outlets was up to 71°C in the counterflow VT. PM separation ratio reached 100% in uniflow VT, regardless of particle size variations. PM separation ratio increased as the inject angle of the VT increased. Optimal VT design was proposed to enhance both energy efficiency and PM separation performance. [ABSTRACT FROM AUTHOR]
Copyright of Separation Science & Technology is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:The vortex tube (VT) is a device known for separating a compressed gas stream into hot and cold fractions. This study numerically investigates its dual potential for thermal separation and particulate matter (PM) removal. Using computational fluid dynamics, the effects of key design parameters and operating conditions on separation performance are analyzed for uniflow and counterflow vortex tubes. The investigated variables include tube diameter, inlet pressure, particle size (0.05 to 10 µm), and gas injection angle. The thermal analysis reveals a strong dependence of temperature separation (ΔT) on inlet pressure and diameter, with combinations of low pressure and large diameters yielding the highest ΔT, in the range of 60 to 70°C. The PM analysis shows that efficiency is governed by a coupled set of variables. Particle size is the dominant factor, with particles larger than 1 µm achieving over 99% removal efficiency. Inlet pressure has a diameter dependent effect; its increase significantly reduces efficiency in large diameter tubes but has a negligible impact in smaller tubes. A larger gas injection angle monotonically increases PM separation by strengthening tangential momentum. Coordinated selection of diameter, inlet pressure, and injection angle enables application specific tuning for simultaneous energy and particulate separation. HIGHLIGHT: A comparison between the counterflow and uniflow types of VTs was carried out. Temperature difference between the cold and hot outlets was up to 71°C in the counterflow VT. PM separation ratio reached 100% in uniflow VT, regardless of particle size variations. PM separation ratio increased as the inject angle of the VT increased. Optimal VT design was proposed to enhance both energy efficiency and PM separation performance. [ABSTRACT FROM AUTHOR]
ISSN:01496395
DOI:10.1080/01496395.2025.2576543