Analysis of the Demagnetization of a PMSG Using a Coupled Electromagnetic–Fluid–Thermal Numerical Model.

Saved in:
Bibliographic Details
Title: Analysis of the Demagnetization of a PMSG Using a Coupled Electromagnetic–Fluid–Thermal Numerical Model.
Authors: Morón-Monreal, Jorge E.1 (AUTHOR), Martinez-Rios, Francisco J.1 (AUTHOR) fjmartinezr@lalaguna.tecnm.mx, Hernandez, Concepcion1 (AUTHOR), Arjona, Marco A.1 (AUTHOR)
Source: Energies (19961073). Dec2025, Vol. 18 Issue 23, p6149. 30p.
Subjects: Demagnetization, Thermal analysis, Natural heat convection, Computer simulation, Computational fluid dynamics, Energy dissipation, Finite element method, Permanent magnet generators
Abstract: This article presents a multiphysics simulation methodology to predict the temperature-dependent demagnetization phenomenon of a 900 W permanent-magnet synchronous generator (PMSG). For the 2D electromagnetic model, a commercial finite element method (FEM) package was used to determine the power loss distribution under steady-state conditions, accounting for temperature-dependent demagnetization. The thermal analysis was carried out on a 3D model using computational fluid dynamics (CFD) software, where a polyhedral mesh, rotor rotation effects, and turbulent modeling were implemented. Two simulation cases were evaluated: Case 1, electromagnetic losses at constant temperature without FEM-CFD coupling; Case 2, bidirectional FEM-CFD coupling under steady-state conditions. The analysis confirms that in Cases 1 and 2, there is no risk of irreversible demagnetization, thus validating the selection of the permanent magnet (PM) and the design of the PMSG. Additionally, the methodology accurately captured the heat transfer effects resulting from natural convection and turbulent flow in the critical regions. The CFD modeling convergence criteria, based on residuals and flow monitors, demonstrated numerical stability and a satisfactory mesh discretization in both the FEM and CFD domains, providing valid feedback on the PM temperatures. The proposed methodology provides a robust and accurate tool for coupled electromagnetic–fluid–thermal analysis of the PMSG at rated operating conditions. [ABSTRACT FROM AUTHOR]
Copyright of Energies (19961073) is the property of MDPI and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
Description
Abstract:This article presents a multiphysics simulation methodology to predict the temperature-dependent demagnetization phenomenon of a 900 W permanent-magnet synchronous generator (PMSG). For the 2D electromagnetic model, a commercial finite element method (FEM) package was used to determine the power loss distribution under steady-state conditions, accounting for temperature-dependent demagnetization. The thermal analysis was carried out on a 3D model using computational fluid dynamics (CFD) software, where a polyhedral mesh, rotor rotation effects, and turbulent modeling were implemented. Two simulation cases were evaluated: Case 1, electromagnetic losses at constant temperature without FEM-CFD coupling; Case 2, bidirectional FEM-CFD coupling under steady-state conditions. The analysis confirms that in Cases 1 and 2, there is no risk of irreversible demagnetization, thus validating the selection of the permanent magnet (PM) and the design of the PMSG. Additionally, the methodology accurately captured the heat transfer effects resulting from natural convection and turbulent flow in the critical regions. The CFD modeling convergence criteria, based on residuals and flow monitors, demonstrated numerical stability and a satisfactory mesh discretization in both the FEM and CFD domains, providing valid feedback on the PM temperatures. The proposed methodology provides a robust and accurate tool for coupled electromagnetic–fluid–thermal analysis of the PMSG at rated operating conditions. [ABSTRACT FROM AUTHOR]
ISSN:19961073
DOI:10.3390/en18236149